26 178
8.5kW
26 179
9.5kW
26 221
9.5kW
26 222
9.5kW
This booklet should be left with the user after installation
IMPORTANT:
and demonstration.
Installation and User Guide

Advertisement

loading

Summary of Contents for Grohe TEMPESTA 100 26 178

  • Page 1 TEMPESTA 100 ELECTRIC SHOWER DESIGN + ENGINEERING GROHE GERMANY 99.0351.031/ÄM 231959/08.14 www.grohe.com 26 178 8.5kW 26 179 9.5kW 26 221 9.5kW 26 222 9.5kW IMPORTANT: This booklet should be left with the user after installation and demonstration. Installation and User Guide...
  • Page 2 THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE AND PERSONS WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LACK OF EXPERIENCE AND KNOWLEDGE IF THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE IN A SAFE WAY AND UNDERSTAND THE HAZARDS INVOLVED.
  • Page 3 These can result from toilets being flushed or We recommend that the installation is done in taps being turned on and off. the following sequence. When this happens your showering a. Fixing the shower to the wall temperature will be held within a controlled b.
  • Page 4 and fixing the bottom position. You may wish to leave both screws at this stage loose as the holes are elongated to allow for adjustment after other connections have taken place. b. PLUMBING WARNING: ENSURE THAT THE MAINS WATER SUPPLY MEETS THE REQUIREMENTS BELOW BEFORE CONTINUING INSTALLATION.
  • Page 5 Note: You may be charged for a service call if it 4. With the isolating valve connected, is due to incorrect installation. flush the pipe work through to remove 5. The shower is designed to have an open any particles etc, before making the final outlet and should only be used with the connection to the shower.
  • Page 6 WARNING: DO NOT FIT A TAP ON THE 3. Cut back cable (fig.7). SHOWER OUTLET. Connect cable to terminal block making sure that all the retaining screws areVERY TIGHT WARNING: and that no cable insulation is trapped under TAKE CARE TO AVOID the screws.
  • Page 7 Ensure temperature Knob is aligned at 6 o’clock, whilst the ‘spindle’ in the product is rotated fully clockwise as shown (fig.9). Ensure the electricity and water are turned on to the unit. Your shower has 2 control knobs and a push-button (fig.12).
  • Page 8 Allow about 20 seconds for the temperature of Water will continue to flow and cool down before the water to stabilise. the heater switches back on again. Note: The ‘Auto Reset’ light may come on at the Final adjustment may be anywhere on the scale. If after turning fully anti-clockwise, water is still start of a showering session if the shower has too hot, adjust Knob ‘A’...
  • Page 9: Cleaning The Filter

    Fax: +44(0)871 200 3415 WARNING: Or alternatively email us on: YOU MUST REGULARLY INSPECT info-uk @grohe.com THE SHOWER HOSE FOR WEAR Remember to quote the exact type of shower, AND DAMAGE AND REPLACE IF as written on the front of the shower and on this NECESSARY, OR EVERY 2 YEARS, leaflet.
  • Page 10: Self Help

    The shower temperature is set too hot causing the thermal cut-out (safety device) to operate. Turn Knob ‘B’ anti-clockwise to increase water flow. Then slowly increase the water Shower temperature by turning Knob ‘B’ cycles from clockwise until a comfortable HOT to showering temperature has been COLD...
  • Page 11: Professional Service

    PROFESSIONAL SERVICE If the previous ‘Self Help’ checks fail to restore the performance, you should seek professional help. The person who installed the shower is probably the best one to investigate and correct it and is 1. Water is heated instantaneously as it flows certainly the person to contact if you have had a over the heating elements in the heat problem in the guarantee period.
  • Page 12 This means that in the winter, flow rate will be less than in the summer to achieve the same outlet temperature. In summer the ‘II’ (2 bars) power setting may give adequate hot water. Effect of Other Water Devices on Incoming Water Supply Your shower is designed to stabilize temperature changes caused by water pressure...
  • Page 13 k) Wall Fixing Key-Hole Slot a) Thermal Cut-Out l) Alternative key-Hole slot b) Heat Exchanger m) Wall Fixing Slot c) Flow Valve d) Pressure Relief Device n) n/a e) On/Off Solenoid Valve o) n/a f) Pressure Switch p) Power on light g) Terminal Block x 2 q) Auto reset light h) Detachable Backplate Section...
  • Page 14 Please Note:- The fitting of Spare Parts must be supervised by a suitably qualified person. Heat Exchanger (8.5kW) Cat No. 93672102 Heat Exchanger (9.5kW) Cat No. 93672103 Heat Exchanger Vessel Cat No. 93672114 Solenoid Valve Cat No. 93672126 Start stop switch Cat No.
  • Page 15 Please DO NOT remove the product prior to making this call as this may invalidate your guarantee. Service and Repair Tel: +44(0)871 200 3414 or email: info-uk@grohe.com We guarantee this product for domestic use only, for a period of 24 months from the date of purchase.
  • Page 17 DESIGN + ENGINEERING GROHE GERMANY 99.496.131/ÄM 226558/01.16 www.grohe.com Prod.-Nr. Ø8 (Ø ") 470-620 "- 24 ") 770-920 "- 36 ") 1000-1150 "- 45 ") Ø8 (Ø ")
  • Page 18 Prod.-Nr.

This manual is also suitable for:

Tempesta 100 26 179Tempesta 100 26 221Tempesta 100 26 222