Deleting Presets ........................96 Copying All Presets ....................... 97 9.4.1 Copying All Presets from the LV 5770 to a USB Memory Device ........97 9.4.2 Copying All Presets from a USB Memory Device to the LV 5770 ........98 10. REMOTE CONTROL ....................99 11.
■ Note about Reading This Manual The contents of this manual contain specialized terminology and may be difficult to understand. If you have any questions about the contents of this manual, please contact your local LEADER agent. ■ Symbols and Terms The following symbols and terms are used in this instruction manual and on the instrument to indicate important warnings and notes.
Page 7
Failing to do so could lead to fire.Turn off the power switch, and remove the power cord from the outlet. After making sure that fire has not spread anywhere, contact your local LEADER agent.
Page 8
Using a power cord that does not meet the standards could lead to fire. If the power cord is damaged, stop using it, and contact your local LEADER agent. Using a damaged power cord could lead to electrical shock or fire.
Page 9
To ensure stable performance, we recommend that you have the instrument calibrated regularly. Also, if the instrument malfunctions, repairs are necessary. For repairs and calibration, contact your local LEADER agent. ■ Routine Maintenance When you clean the instrument, remove the power plug from the outlet.
1. INTRODUCTION INTRODUCTION Thank you for purchasing this LEADER instrument. To use this instrument safely, read this instruction manual thoroughly, and make sure that you know how to use the instrument properly. If some point about the operation of this instrument is still unclear after you have read this instruction manual, refer to the contact information on the back cover of the manual to contact LEADER, or contact your local LEADER agent.
To continually use the last-memory feature, we recommend that you replace the backup battery with a new one every five years after you purchase the instrument. You cannot replace the backup battery yourself. Contact your local LEADER agent.
1. INTRODUCTION 1.2.8 About the LCD Panel There may be a small number of pixels in the LCD panel that do not light or are always on. Note that this is not a malfunction. The LCD panel supports a large number of video signals. SDI input signals are displayed asynchronously on the LCD.
1. INTRODUCTION About Terminology Used in this Manual ● Single Input Mode This refers to the mode in which the SIM key is off. Press the A and B keys to switch between measuring the signal that is being applied to SDI INPUT A and the signal that is being applied to SDI INPUT B, respectively.
SPECIFICATIONS General The LV 5770 is a waveform monitor that supports 3G-SDI, HD dual link, HD-SDI, and SD-SDI signals. It is light weight and comes at a low cost but has a variety of technically advanced features including simultaneous monitoring of two SDI signals, lip sync measurement, and ANC data analysis.
Page 15
Not only can captured data be displayed by the LV 5770, but it can also be compared with an input signal or saved to a USB memory device. It is easy to view the saved data on a PC.
Page 16
● Digital Audio I/O (LV 5770SER41 and LV 5770SER43) When the digital audio I/O option is installed in the LV 5770, the LV 5770 can display the external digital audio in addition to the embedded audio. The eight I/O connectors—16 channels—can be switched between input and output in groups of four connectors—8...
Page 17
● Dolby Option (LV 5770SER41 and LV 5770SER43) The addition of the Dolby option enables the LV 5770 to decode and display the Dolby E or Dolby Digital signals that are compressed in embedded audio or digital audio signals. ●...
2. SPECIFICATIONS Specifications 2.3.1 SDI Video Signal Formats and Standards (LV 5770SER08 and LV 5770SER09A) Bit Rate 3G-SDI 2.970 Gbps or 2.970/1.001 Gbps HD-SDI 1.485 Gbps or 1.485/1.001 Gbps SD-SDI 270 Mbps Table 2-1 SD-SDI video signal formats and standards Color System Quantization Scanning...
Page 19
2. SPECIFICATIONS Table 2-4 3G-SDI level A video signal formats and standards Color System Quantization Scanning Frame (Field) Rates Compliant Standard 4:2:2 10 bits 1080p 60/59.94/50 SMPTE ST 424 SMPTE ST 425 12 bits 1080p 30/29.97/25/24/23.98 1080PsF 30/29.97/25/24/23.98 1080i 60/59.94/50 4:4:4 10 bits 1080p...
Page 20
Format Setting Automatic and manual Automatic 3G-SDI and HD Dual Link The LV 5770 detects the format information within the payload ID (SMPTE ST 352) and automatically sets the format. HD-SDI and SD-SDI The LV 5770 determines the format from the input signal's synchronization information and automatically sets the format.
2. SPECIFICATIONS 2.3.2 Embedded Audio Playback Format (LV 5770SER41/LV 5770SER43 and LV 5770SER08/LV 5770SER09A) Compliant Standards 3G-SDI, HD-SDI, and HD Dual Link SMPTE ST 299 SD-SDI SMPTE ST 272 Format LPCM, Dolby-E (option), Dolby Digital (option) Quantization 24 bits Clock Generation Generated from the video clock Synchronization All audio channels must be synchronized with the video...
2. SPECIFICATIONS SDI Output Output Connectors Two BNC connectors Output Signal Serial reclocked input SDI signal 3G-SDI, HD-SDI, and SD-SDI 1 output (switchable between channels A and B) 1 output (fixed to channel B) HD Dual Link 1 output (link channel A or B) Output Impedance 75 Ω...
2. SPECIFICATIONS 2.3.7 Audio I/O Connectors (LV 5770SER41, LV 5770SER42, and LV 5770SER43) I/O connectors of the digital audio (LV 5770SER41 and LV 5770SER43) I/O Connector BNC connector Group A 4 connectors, 8 channels Group B 4 connectors, 8 channels I/O Switching Switching between the connections (4 connectors, 8 channels)
2. SPECIFICATIONS 2.3.8 Video Output Connectors DVI-D Output Connector Output Connector One DVI-D connector Output Signal Digital signal of the LCD display Resolution XGA (1024 × 768) Aspect Ratio Signal Format Single link TMDS Not supported HOT PLUG Detection Not supported Picture Monitor Output Connector (LV 5770SER08 and LV 5770SER09A)(*1) Output Connector Output Signal...
LV 5770 can load. Data Input Data saved to USB memory can be loaded and displayed on the LV 5770. 2.3.12 Frame Capture (LV 5770SER08 and LV 5770SER09A) Function...
Preset Loading Method Front panel, remote control connector (*2), or ethernet Copying All preset data can be copied from the LV 5770 to a USB memory device or from a USB memory device to the LV 5770. Settings related to whether the instrument is on or off, the ethernet connector, the remote control connector, the date, and the time are not saved.
Page 27
2. SPECIFICATIONS Display Colors Seven colors to choose from; a different color for each input channel Vertical Axis Gain ×1, ×5 Variable Gain ×0.2 to ×2 Amplitude Accuracy ×1 ±0.5 % ×5 ±0.2 % 3G-SDI, HD Dual Link (1080p/60, 1080p/59.94, 1080p/50) Y Signal ±0.5 % for 1 to 60 MHz Signal...
2. SPECIFICATIONS 2.3.16 Analog Composite Signal Video Waveform Display (LV 5770SER03A) Waveform Operations Line Select Selected line display Sweep Mode H, V Display Color Seven colors to choose from Vertical Axis Scale Composite Signal NTSC -40 to 100 IRE -0.3 to 0.7 V HD Tri-level Sync Signal -0.3 to 0.7 V, -43 to 100 % (the unit is switchable between V and %)
2. SPECIFICATIONS 2.3.17 SDI Signal Vector Waveform Display (LV 5770SER08 and LV 5770SER09A) Simul Mode Display Format Mixed, tiled Display Colors Seven colors to choose from; a different color for each input channel Blanking Interval(*1) Masked Pseudo-Composite Display Artificially converts component signals into composite signals and displays the result Line Select Selected line display...
2. SPECIFICATIONS 2.3.19 SDI Signal 5-Bar Display (LV 5770SER08 and LV 5770SER09A) Simul Mode Display Format Tiled only Function Converts an SDI signal into Y, R, G, B, and composite values and then displays the five peak levels Channel Assignment RGB, GBR Scale mV, %...
Page 31
2. SPECIFICATIONS Percentage Display Displays luminance or RGB components as percentages Level Display Displays RGB components with 256 levels (8 bits) Measured points Measurement sizes 1 pixel, 3 × 3 pixels, or 9 × 9 pixels CINELITE Advanced Display Features Synchronized marker display, vector marker display Synchronized Marker Display Synchronizes the markers on the vector display or waveform display to the measurement points of the...
2. SPECIFICATIONS 2.3.21 Analog Composite Signal Picture Display (LV 5770SER03A) Quantization 8 bits Display Sizes Fit, full frame, real, ×2 Frame Rate The frame rate is converted and displayed using the internal sync signal Aspect Marker Display 16:9, 14:9, 13:9 Aspect Marker Format Line, shadow (99 levels), black Safety Marker Size...
2. SPECIFICATIONS signal for the right eye on a time sharing display Inverted Display Horizontal Inversion Inverts the picture and video signal waveform (*1) Vertical Inversion Inverts the picture Inverted Channel Inverts video signal for the left eye and video signal for the right eye separately Grid Display Description...
Page 34
1 to 5000 ms Parity Error Counts the number of times that the input signal's parity bit and the parity bit recalculated by the LV 5770 differ Validity Error Counts the number of times that the input signal's validity bit is 1...
Page 35
2. SPECIFICATIONS Loudness Display Function Loudness chart display, numeric display, log, level meter display (*1), peak value display (*1) Compliant Standard ITU-R BS.1770, ARIB TR-B32, EBU R128, ATSC A/85 Measurement Channel Simultaneous measurement of two audio sources (*1) Mode (Main) Monaural, stereo, 5.1, user specified channel Mode (Sub)(*1) Off, monaural, stereo...
2. SPECIFICATIONS 2.3.24 Analog Audio Display (LV 5770SER42) Input Signal Analog audio input Displayed Channels Up to 8 channels Display Type Level meter, Lissajous, surround, status, loudness Level Meter Display The specifications other than those listed here are the same as the digital audio specifications Scale Reference Level Scales 4 dBu to -20 dBFS Level Accuracy...
Page 37
2. SPECIFICATIONS to 3FFh in locations other than TRS and ADF Dual Link Phase Difference Error Detects errors when the phase difference between links A and B is 100 clocks or more Cable Length Measurement Error (LV 5770SER09A) Displays an error if the specified cable length is exceeded 3G-SDI 10 to 105 m, 5 m steps...
Horizontal ±1 line 2.3.27 Event Log (LV 5770SER08, LV 5770SER09A, LV 5770SER41, and LV 5770SER43) Function Records detected errors, events—such as the LV 5770 switching between input signals, and time stamps. Recording Capacity Up to 1000 events Operation Records all events from start to finish...
2. SPECIFICATIONS 2.3.28 SDI Analysis Features (LV 5770SER08 and LV 5770SER09A) Data Dump Display HD-SDI and SD-SDI Display Format Displays data separated by serial data sequence or by channel 3G-SDI Display Format Stream 1, stream 2, stream A and B simultaneously HD Dual Link Display Format Link A, link B, link A and B simultaneously Line Select...
Reference Signal A Leader TSG that supports lip syncing Measurement Method Measures the time difference when the luminance level of the video signal exceeds the specified value and when...
2. SPECIFICATIONS Supported Audio Signals Embedded audio signal, digital audio signal Measurement Range (Bar Display) ±50 ms, ±100 ms, ±500 ms, ±1.0 s, ±2.5 s Measurement Range (Numeric Display) ±3999 ms Measurement Resolution 1 ms Thumbnail Display Picture, audio level meter 2.3.31 SDI Closed Caption Packet Display (LV 5770SER08 and LV 5770SER09A) Table 2-7 SD-SDI video signal formats and standards...
2. SPECIFICATIONS 2.3.32 Eye Pattern Display (LV 5770SER09A) Display Displays the input SDI waveform before equalizing 3G-SDI, HD-SDI, SD-SDI Displays channel A or B, whichever is selected HD Dual Link Displays link A or B, whichever is selected Method Equivalent time sampling Frequency Response 7 GHZ -3dB (converted from the rise time) Amplitude Accuracy...
2. SPECIFICATIONS 2.3.33 Jitter Display (LV 5770SER09A) Display Displays the jitter component of an SDI signal 3G-SDI, HD-SDI, SD-SDI Displays channel A or B, whichever is selected HD Dual Link Displays link A or B, whichever is selected Method Phase detection method Gain ×8, ×2, ×1 Measurement Range...
2. SPECIFICATIONS 2.3.34 Eye Pattern and Jitter Detection (LV 5770SER09A) Error Detection On or off per item Error Threshold Settings Can be set individually for 3G-SDI, HD-SDI, and SD-SDI signals Event Log Stores eye patterns and jitter errors Threshold Values 100 % of the values in the SMPTE standard Eye-Pattern Amplitude Upper Limit...
2. SPECIFICATIONS 2.3.36 Alarm Output Feature Display Indication When an error occurs or the fan stops rotating, an alarm is displayed. Remote Control Connector Output Each time that an error occurs or the fan stops rotating, a signal is transmitted from the remote control connector to indicate this occurrence.
3. PANEL DESCRIPTION PANEL DESCRIPTION Front Panel Figure 3-1 Front panel Table 3-1 Front panel description Name Description Measures the SDI signal being applied to the LV 5770SER08 or LV 5770SER09A. CMPST Measures the composite signal or HD tri-level sync signal being applied to the LV 5770SER03A.
Page 47
3. PANEL DESCRIPTION Name Description F•1 to F•7 Carries out the corresponding function menu operation. See section 4.6.2, “Function Menu Operations.” 1 to 4 Select the display area. See section 5.2, “Selecting the Display Area.” V POS Adjusts the vertical position of the video signal waveform or eye pattern waveform. Press this key to return the position to the reference position.
Name Description connected to this jack, the LV 5770 transmits the audio that is embedded in an SDI signal or the audio that is applied to the LV 5770SER41 or LV 5770SER43. This requires the LV 5770SER41 or LV 5770SER43.
Page 49
3. PANEL DESCRIPTION Name Description AC inlet Attach the included cover/inlet stopper to the AC inlet. See section 4.1, “Cover/Inlet Stopper.” Ground This is used to connect the instrument to an external ground. terminal REMOTE This is a D-sub, 15-pin remote control connector. This can be used to execute actions such as loading presets.
4. BEFORE YOU BEGIN MEASURING BEFORE YOU BEGIN MEASURING Cover/Inlet Stopper A cover/inlet stopper is included with the instrument. Use this device to prevent the power cord from being pulled free of the AC inlet. 4.1.1 Attaching the Cover/Inlet Stopper Cover the power cord with the cover/inlet stopper.
To turn on the power, press the power switch. The power switch LED lights, and the instrument turns on. When you turn on the power, the LV 5770 starts with the same panel settings that were being used when it was last turned off.
Page 52
See section 5.4, “Selecting the Input Channel.” • Cables It has been confirmed for each channel that errors do not occur when the LV 5770 receives an 800 mVp-p stress pattern through the following cables. LS-5CFB cable, 70 m LS-5CFB cable, 110 m L-5C2V cable, 260 m •...
SDI INPUT A or SDI INPUT B. Use a commercially available HDMI cable to connect the LV 5770 to an LCD monitor. Press A or B to select the output channel. For HD dual link signals, a signal consisting of the combination of links A and B is generated.
(phase difference display). (*1) Apply an external sync signal to an external sync signal input connector, and then press EXT. The LV 5770 determines the sync signal format automatically. As shown in the figure below, the external sync signal input connectors are loop-through.
Page 55
4. BEFORE YOU BEGIN MEASURING External sync signals that are compatible with each input signal are indicated with a check mark in the following table. Table 4-2 External sync signal formats (SD, HD, and HD dual link) Input Signal Format HD dual link NTSC with 10 field ...
Page 56
4. BEFORE YOU BEGIN MEASURING Table 4-3 External sync signal formats (3G) Input Signal Format 3G-A 3G-B 3G-B (2map) NTSC with 10 field ID (59.94 Hz)(*1) NTSC (59.94 Hz) ...
4. BEFORE YOU BEGIN MEASURING 4.4.5 Composite Signal I/O (LV 5770SER03A) Figure 4-10 Composite I/O connectors • Signal Input Apply an NTSC/PAL composite signal or an HD tri-level sync signal to INPUT A or INPUT B. To switch the measurement channel, press A or B. Note that pressing the SIM key has no effect.
4. BEFORE YOU BEGIN MEASURING Use the system settings to set the function of the audio I/O connectors to input or output. Before you apply signals, check that the function of the connectors has been set to input. Failing to do so could damage the instrument. Use the output signal for monitoring purposes.
100 kΩ. • About the Unit LV 5770 audio signals are displayed in units of dBFS with 4 dBu scaled to -20 dBFS. A conversion table between dBu and dBFS is shown below. Table 4-5 dBu, dBFS conversion table...
4. BEFORE YOU BEGIN MEASURING General Display Explanation Figure 4-14 General display explanation Table 4-6 General display explanation Name Description Date and time The date and time are displayed here. See sections 7.2.1, “General Settings” and 7.2.4, “Setting the Date and Time.”...
Alarm indication This displays various alarms. If either of the following alarms is displayed, contact your local LEADER agent. FAN ALARM: This appears when there is a problem with the fan. OVER HEAT: This appears when the internal temperature has risen to an abnormal level.
4. BEFORE YOU BEGIN MEASURING 4.6.2 Function Menu Operations This section explains how to operate the function menu, using the function menu on the vector display as an example. The function menu items correspond to F•1 to F•7. Figure 4-15 Function menu operations •...
Enabling and Releasing the Key Lock You can prevent accidental operations on the LV 5770 by enabling the key lock. The key lock disables all LV 5770 keys except for the power switch. (Remote control is still valid even if the key lock is enabled.)
See section 7.4, “Setting the Shortcut Key.” • DIRECT The panel settings that are registered to the SHORT key are loaded. To register the panel settings, configure the LV 5770 to the settings that you want to register, press MEM, and then press SHORT. • VOLUME You can adjust the headphone volume by pressing SHORT and then turning the function dial (F•D).
BASIC OPERATING PROCEDURES This chapter explains the basic operating procedures of the LV 5770. We recommend that you follow these basic operations until you fully understand how the LV 5770 is designed to operate. Figure 5-1 Operating procedures Select the display format.
Selecting the Display Format The LV 5770 supports both a multi-screen display and a 1-screen display. Press MULTI to switch between the 1-screen display and the multi-screen display. The key's LED lights when the multi-screen display is active.
5. BASIC OPERATING PROCEDURES Selecting the Display Area The LV 5770 is composed of four screens. Press a key from 1 to 4 to select the area that you want to operate. When the menu is being displayed on the multi-screen display, the selected area is displayed with a blue border.
Figure 5-6 Single input mode and simul mode Selecting the Display Mode The LV 5770 has six display modes: WFM (video signal waveform display), VECT (vector display), PIC (picture display), AUDIO (audio display), STATUS (status display), and EYE (eye pattern display). Press MODE on the front panel to select the display mode.
Page 69
5. BASIC OPERATING PROCEDURES WFM(*1) VECT(VECTOR)(*1) VECT(5BAR)(*1) AUDIO STATUS Figure 5-7 Selecting the display mode The audio meter is not displayed if an LV 5770SER41 or LV 5770SER43 is not installed in the LV 5770.
DETAILED MEASUREMENT EXAMPLES This chapter explains detailed measurement examples. For the basic operating procedures, see chapter 5, “BASIC OPERATING PROCEDURES.” Initialize the LV 5770 immediately before you perform the operating procedures shown here. See section 7.7, “Initializing Settings.” SDI Signal Measurement •...
Apply an SDI signal to SDI INPUT A or SDI INPUT B on the rear panel. Turn the MULTI key off (optional). The LV 5770 switches to the 1-screen display, which is easier to view. (On the multi-screen display, one of these displays is shown.) This is not supported in simul mode or on the multi-screen display of 3G-B(2map) signals.
Apply an SDI signal to SDI INPUT A or SDI INPUT B on the rear panel. Turn the MULTI key off (optional). The LV 5770 switches to the 1-screen display, which is easier to view. Press AUDIO. Press F•1 SOURCE SELECT and then F•2 1ST GRP SELECT or F•3 2ND GRP SELECT to select the measurement group.
Check that the Audio BNC settings are set to INPUT on the REAR PANEL SETUP tab in the system settings. These settings are set to INPUT when the LV 5770 is initialized. See section 7.1.2, “Rear Panel Settings.”...
Check that the ANALOG AUDIO setting is set to INPUT on the REAR PANEL SETUP tab in the system settings. This setting is set to INPUT when the LV 5770 is initialized. See sections 4.4.7, “Analog Audio Signal I/O (LV 5770SER42)” and 7.1.2, “Rear Panel Settings.”...
6. DETAILED MEASUREMENT EXAMPLES Embedded Audio Signal Output You can generate channels 1 to 16 of an audio signal that is embedded in an SDI signal from the rear panel DIGITAL AUDIO IN/OUT connectors. Group A generates channels 1 to 8, and group B generates channels 9 to 16.
6. DETAILED MEASUREMENT EXAMPLES Analog Audio Signal Output You can perform a D/A conversion on and generate up to eight channels of embedded audio signals or external digital audio signals as analog audio signals from the rear panel ANALOG AUDIO connector. This section will show the procedure for generating embedded audio signals.
7. SYSTEM SETTINGS SYSTEM SETTINGS You can use the system menu to configure LV 5770 settings and optional unit settings. To display the system menu, press SYS. SYS → Figure 7-1 System menu I/O Settings To configure the I/O settings, press F•1 FORMAT IN OUT on the system menu. FORMAT IN OUT is a tab menu.
Page 78
“ILLEGAL FORMAT” will be displayed. Specify a correct format. It may take the LV 5770 approximately 10 seconds to switch to a different format. Table 7-1 Input format settings Link Format...
Page 79
7. SYSTEM SETTINGS Link Format Color System Pixel Depth Scanning Active Sample Frame Rate (*1) 3G-A YCbCr(4:2:2) 10bit 1080P 1920 60/59.94/50 12bit 1080P 1920 30/29.97/25/24/23.98 1080i 1920 30/29.97/25 1080PsF 1920 30/29.97/25/24/23.98 YCbCr(4:4:4) 10bit 1080P 1920 30/29.97/25/24/23.98 1080i 1920 30/29.97/25 1080PsF 1920 30/29.97/25/24/23.98 720P...
7. SYSTEM SETTINGS Link Format Color System Pixel Depth Scanning Active Sample Frame Rate (*1) 3G-B(2map) YCbCr(4:2:2) 10bit 1080P 1920 30/29.97/25/24/23.98 1080i 1920 30/29.97/25 1080PsF 1920 30/29.97/25/24/23.98 720P 1920 60/59.94/50/ 30/29.97/25/24/23.98 Note that when i/PsF Select is set to Interlace, the frame rate is displayed. For example, if the field rate is 59.94 Hz, set the frame rate to 29.97.
Page 81
7. SYSTEM SETTINGS ● GROUP A OUT SEL and GROUP B OUT SEL (LV 5770SER41 and LV 5770SER43) When GROUP A or GROUP B is set to OUTPUT, select the corresponding output signal. The LV 5770SER08 or LV 5770SER09A is required to generate embedded audio signals.
Page 82
7. SYSTEM SETTINGS ● Color Format (LV 5770SER08 and LV 5770SER09A) Select the picture monitor output format. If you select Auto, the signal is generated in the same format as the input signal. Auto / YCbCr 422 / YCbCr 444 / RGB 444 ●...
7. SYSTEM SETTINGS Configuring the LV 5770 To configure the LV 5770, press F•2 SYSTEM SETUP on the system menu. SYSTEM SETUP is a tab menu. For details on how to operate tab menus, see section 4.6.3, “Tab Menu Operations.”...
Page 84
7. SYSTEM SETTINGS ● Format (LV 5770SER03A, LV 5770SER08, and LV 5770SER09A) Turn the format indication (for example, 1080i/59.94 or NTSC) that is shown at the top of the screen on or off. ON / OFF ● Date Select the display format for the date that is shown in the upper left of the screen. y = the year in the Gregorian calendar, m = the month, d = the day OFF / y/m/d / m/d/y / d/m/y ●...
Configuring Ethernet Settings Configure the Ethernet settings on the ETHERNET SETUP tab. The settings that you specify here will not be initialized even if you initialize the LV 5770. In addition, they are not registered to presets. See chapter 11, “ETHERNET REMOTE CONTROL.”...
Page 86
7. SYSTEM SETTINGS ● Ethernet Select Select how to set the IP address. This setting is enabled after you restart the LV 5770. DHCP: The IP address, subnet mask, and default gateway are set automatically. Set the IP address, subnet mask, and default gateway manually.
Remote Control Settings Use the REMOTE SETUP tab to configure remote control settings. The settings that you specify here will not be initialized even if you initialize the LV 5770. In addition, they are not registered to presets. See chapter 10, “REMOTE CONTROL.”...
ON. To set the date and time manually, set SNTP Client Select to OFF, and then press F•1 COMPLETE. Then, press F•2 SYSTEM SETUP again. The settings that you specify here will not be initialized even if you initialize the LV 5770. In addition, they are not registered to presets.
Displaying System Information To display the system information, press F•3 SYSTEM INFO on the system menu. You can use this screen to view the LV 5770 firmware version and the types of installed optional units. SYS → F•3 SYSTEM INFO →...
7. SYSTEM SETTINGS Configuring License Settings To configure the license settings, press F•5 LICENSE SETUP on the system menu. You can use this screen to view the MAC address and install options. For details on installing options, see the instruction manuals for the options. SYS →...
7. SYSTEM SETTINGS Initializing Settings To initialize the settings, press F•7 INITIALIZE on the system menu. To proceed with the initialization, press F•1 INIT YES. To cancel the initialization, press F•3 INIT NO. SYS → F•7 INITIALIZE → Figure 7-10 INITIALIZE menu When you initialize the settings, all the settings—excluding those listed below—are initialized.
You can use the screen capture feature to capture still-image data of the screen. You can save the captured data to USB memory or overlay it on the input signal on the LV 5770 display. ● Frame Capture (LV 5770SER08 and LV 5770SER09A) You can use the frame capture feature to capture single frames of data from the SDI signal.
Configure the LV 5770 so that the display that you want to capture appears on the screen. Press CAP. When you press CAP, the LV 5770 stores a screen capture of the display in its internal memory. You can also take screen captures by pressing F•2 REFRESH while the capture menu is displayed.
If you press CAP and perform an operation such as changing the display mode, the acquired screen capture data is deleted. However, by saving the screen capture data to a USB memory device in BSG format, you can display the screen capture data on the LV 5770 even after you restart the instrument.
USB memory as .bsg files, follow the procedure below. (Screen capture data that has been saved in BMP format and screen capture data that has been saved in BSG format on a different model cannot be displayed on the LV 5770.) Press CAP.
8. CAPTURE FEATURE 8.1.5 Deleting Screen Capture Data Saved to a USB Memory Device To delete screen capture data that has been saved to a USB memory device, follow the procedure below. (You can also use a PC to delete the data.) Press CAP.
Press F•1 TRIGGER to select MANUAL. Press F•2 REFRESH. One frame of data is captured in the LV 5770. (In simul mode, the data of both channels A and B is captured.) The captured frame data is cleared when you change the input channel or other...
Page 98
When the message below appears, press any key except for the power key. If an error occurs during error standby, the LV 5770 captures the frame data at that point and stops the frame capture. (In simul mode, if an error occurs on channel A or channel B, the LV 5770 captures the frame data of the channel in which the error occurred and stops the frame capture.)
Saving to a USB Memory Device The frame data captured in the LV 5770 is cleared when the power is turned off. If you want to display it later even after the power is turned off, save the data to USB memory by following the procedure below (save the data in FRM format).
Page 100
F•4 FILE TYPE are set to OFF, or when there is no frame data captured in the LV 5770. When the input signal is 1080i/59.94 and all the file types that you can select with F•4 FILE TYPE are set to ON, it takes about 50 seconds to save the data.
Turn the function dial (F•D) to select the .frm file that you want to display. Press F•1 RECALL. To display frame data, the LV 5770 must be receiving a signal whose format is the same as that of the saved data. The FORMAT item at the bottom of the display shows the format of the saved data.
8. CAPTURE FEATURE 8.2.5 Deleting Frame Capture Data Saved to a USB Memory Device To delete frame capture data that has been saved to a USB memory device, follow the procedure below. (You can also use a PC to delete the data.) Press F•6 RECALL on the capture menu.
• Date and time settings (DATE&TIME) Registering Presets To register a preset, follow the procedure below. Set the LV 5770 to the settings that you want to register. Press MEM. The preset registration display appears. Figure 9-1 Preset registration display...
Page 104
9. PRESET FEATURE Press F•1 COMMENT INPUT. The comment input display appears. You can also copy a comment from a preset that already has a comment saved to it. To copy a comment, on the preset registration display, move the cursor to the preset that has the comment that you want to copy, and press the function dial (F•D).
9. PRESET FEATURE Loading Presets To load a preset, follow the procedure below. Press RCLL. The preset load menu appears. Figure 9-4 Preset load menu Press a key from F•1 NO.1 to F•6 NO.6. If the preset that you want to load is number 7 or greater, press F•7 more or turn the function dial (F•D).
Copying All Presets 9.4.1 Copying All Presets from the LV 5770 to a USB Memory Device To copy all the presets from the LV 5770 to a USB memory device, follow the procedure below. Press MEM. The preset registration display appears.
PRESET_00.PRE (to PRESET_59.PRE) ..Preset number 1 to number 60 9.4.2 Copying All Presets from a USB Memory Device to the LV 5770 To copy all the presets from a USB memory device to the LV 5770, follow the procedure below. Press MEM.
10. REMOTE CONTROL 10. REMOTE CONTROL You can use the remote control connector on the rear panel to load presets, transmit alarm signals, and perform other operations. Use the supplied 15-pin D-sub connector to control the LV 5770. ● Pinout Example This section contains a diagram of the remote control connector, displayed as it appears on the rear panel, and a table that describes the connector's pinout.
Page 109
10. REMOTE CONTROL ● Configuring the LV 5770 To set the remote control connector, use the system settings. For details, see section 7.2.3, “Remote Control Settings.” SYS → F•2 SYSTEM SETUP → F•3 NEXT TAB → F•3 NEXT TAB →...
Page 110
10. REMOTE CONTROL After a setting is made, it may take about 3 seconds for the operation to finish. If you configure subsequent settings before the initial operation finishes, only the last setting will take effect. All settings in between will be discarded. (In the following example, remote control 2 will be discarded.) Figure 10-4 Remote control timing 2 ●...
Page 111
10. REMOTE CONTROL The control table when Remote Mode is set to BINARY is shown below. Table 10-3 Loading presets (BINARY) Preset...
Page 112
10. REMOTE CONTROL Preset ● Controlling the Loudness Measurement The control table when Remote Select is set to Recall and Loudness is shown below. Table 10-4 Controlling the loudness measurement 9p (/P8) 8p (/P7) Clear the loudness measurement Start the loudness measurement Stop the loudness measurement...
LEADER does not guarantee that this feature will work in any network environment. 11.1 TELNET From a PC connected to the same network as the LV 5770, most of the operations that you can perform from the front panel can be controlled remotely. 11.1.1 Procedure Configure the Ethernet settings on the LV 5770's ETHERNET SETUP tab.
Examples of how to enter commands are shown below. With the factory default settings, return values are returned only for queries. If you want the LV 5770 to output return values for all commands, send a "REMOTE:REPLY" with the parameter set to ON.
11.1.3 TELNET Commands TELNET commands follow the LV 5770 or the unit menu structure. For explanations of each item, see the LV 5770 or the unit instruction manual. Depending on the current settings, some of the items that are described in this manual may be invalid.
Page 119
11. ETHERNET REMOTE CONTROL Command Parameter VECTOR:LINE_SELECT ON / ACH / BCH / BOTH / 2MAP_S1 / 2MAP_S2 / OFF / CINELITE / ? VECTOR:LINE_SELECT:FIELD FIELD1 / FIELD2 / FRAME / ? VECTOR:LINE_NUMBER 1 to 1125 / ? VECTOR:MARKER ON / OFF / ? VECTOR:MODE VECTOR / 5BAR / ? VECTOR:5BAR:SCALE...
Page 120
11. ETHERNET REMOTE CONTROL Command Parameter PICTURE:BRIGHTNESS -50.0 to 50.0 / ? PICTURE:CONTRAST 0.0 to 200.0 / ? PICTURE:GAIN:R 0.0 to 200.0 / ? PICTURE:GAIN:G 0.0 to 200.0 / ? PICTURE:GAIN:B 0.0 to 200.0 / ? PICTURE:GAIN:CHROMA 0.0 to 200.0 / ? PICTURE:BIAS:R -50.0 to 50.0 / ? PICTURE:BIAS:G...
Page 121
11. ETHERNET REMOTE CONTROL Command Parameter PICTURE:DISPLAY:THUMBNAIL:WFM ON / OFF / ? PICTURE:DISPLAY:THUMBNAIL:HISTO ON / OFF / ? PICTURE:DISPLAY:THUMBNAIL:HISTO:FORM LUMA / ALIGN / MIX / ? PICTURE:DISPLAY:THUMBNAIL:HISTO:Y ON / OFF / ? PICTURE:DISPLAY:THUMBNAIL:HISTO:R ON / OFF / ? PICTURE:DISPLAY:THUMBNAIL:HISTO:G ON / OFF / ? PICTURE:DISPLAY:THUMBNAIL:HISTO:B ON / OFF / ? PICTURE:DISPLAY:SD...
Page 124
11. ETHERNET REMOTE CONTROL Command Parameter STATUS:ANC:PKT:ARIB:NETQ:BIT:Q25 ON / OFF / ? STATUS:ANC:PKT:ARIB:NETQ:BIT:Q26 ON / OFF / ? STATUS:ANC:PKT:ARIB:NETQ:BIT:Q27 ON / OFF / ? STATUS:ANC:PKT:ARIB:NETQ:BIT:Q28 ON / OFF / ? STATUS:ANC:PKT:ARIB:NETQ:BIT:Q29 ON / OFF / ? STATUS:ANC:PKT:ARIB:NETQ:BIT:Q30 ON / OFF / ? STATUS:ANC:PKT:ARIB:NETQ:BIT:Q31 ON / OFF / ? STATUS:ANC:PKT:ARIB:NETQ:BIT:Q32...
Page 125
11. ETHERNET REMOTE CONTROL Command Parameter STATUS:ERROR:AUDIO:BCH ON / OFF / ? STATUS:ERROR:AUDIO:DBN ON / OFF / ? STATUS:ERROR:AUDIO:PARITY ON / OFF / ? STATUS:ERROR:AUDIO:INHIBIT ON / OFF / ? STATUS:ERROR:AUDIO:SAMPLE ON / OFF / ? STATUS:ERROR:GAMUT:LPF HD1M_SD1M / HD2.8M_SD1M / OFF / ? STATUS:ERROR:GAMUT ON / OFF / ? STATUS:ERROR:GAMUT:UPPER...
Page 126
11. ETHERNET REMOTE CONTROL Command Parameter STATUS:ERROR:SDI:CABLE_WAR_SD 50 to 300 / ? None EYE:MODE EYE / JITTER / ? EYE:INTEN:EYE -128 to 127 / ? EYE:INTEN:SCALE -8 to 7 / ? EYE:COLOR:EYE WHITE / YELLOW / CYAN / GREEN / MAGENTA / RED / BLUE / ? EYE:COLOR:SCALE WHITE / YELLOW / CYAN / GREEN / MAGENTA / RED /...
Page 127
11. ETHERNET REMOTE CONTROL Command Parameter EYE:ERROR:3G:OVERSHOOT_FALL:MAX 0 to 200 / ? EYE:ERROR:HD:AMPLITUDE ON / OFF / ? EYE:ERROR:HD:AMPLITUDE:UPPER 80 to 140 / ? EYE:ERROR:HD:AMPLITUDE:LOWER 40 to 100 / ? EYE:ERROR:HD:RISETIME ON / OFF / ? EYE:ERROR:HD:RISETIME:MAX 40 to 140 / ? EYE:ERROR:HD:FALLTIME ON / OFF / ? EYE:ERROR:HD:FALLTIME:MAX...
Page 128
11. ETHERNET REMOTE CONTROL Table 11-4 LV 5770SER03A commands Command Parameter None WFM:INTEN:WFM -128 to 127 / ? WFM:COLOR WHITE / YELLOW / CYAN / GREEN / MAGENTA / RED / BLUE / MULTI / ? WFM:INTEN:SCALE -8 to 7 / ? WFM:SCALE:COLOR WHITE / YELLOW / CYAN / GREEN / MAGENTA / RED / BLUE / ?
Page 129
11. ETHERNET REMOTE CONTROL Command Parameter VECTOR:DISPLAY:SCH:DATA ? (Return value: SCH) VECTOR:DISPLAY:THUMBNAIL:AUDIO ON / OFF / ? VECTOR:DISPLAY:THUMBNAIL:PICTURE ON / OFF / ? VECTOR:DISPLAY:THUMBNAIL:HISTO ON / OFF / ? VECTOR:DISPLAY:THUMBNAIL:HISTO:FORM LUMA / ALIGN / MIX / ? VECTOR:DISPLAY:THUMBNAIL:HISTO:Y ON / OFF / ? VECTOR:DISPLAY:THUMBNAIL:HISTO:R ON / OFF / ? VECTOR:DISPLAY:THUMBNAIL:HISTO:G...
Page 130
11. ETHERNET REMOTE CONTROL Command Parameter PICTURE:DISPLAY:THUMBNAIL:HISTO:Y ON / OFF / ? PICTURE:DISPLAY:THUMBNAIL:HISTO:R ON / OFF / ? PICTURE:DISPLAY:THUMBNAIL:HISTO:G ON / OFF / ? PICTURE:DISPLAY:THUMBNAIL:HISTO:B ON / OFF / ? STATUS None STATUS:EXT_REF None STATUS:EXT_REF:USER_REF None STATUS:EXT_REF:DEFAULT None STATUS:EXT_REF:REF:DATA ? (Return value: USER_REF / DEFAULT) STATUS:EXT_REF:STAT:DATA ? (Return value: INT / HD / BB / NO_SIGNAL) STATUS:EXT_REF:H_TIME:DATA...
11. ETHERNET REMOTE CONTROL 11.2 The files that are generated by the LV 5770 can be transferred to a PC connected to the same network. 11.2.1 Procedure Configure the Ethernet settings on the LV 5770's ETHERNET SETUP tab. Set the IP Address, and set FTP Server Select to ON.
11. ETHERNET REMOTE CONTROL Type the user name and password. The user name and password are "LV5770". Use uppercase for all characters. When the user name and password are entered correctly, "ftp>" appears. Connected to ***.***.***.***. 220 FTP Server ready User (***.***.***.***:(none)): LV5770 ..
11. ETHERNET REMOTE CONTROL 11.2.3 FTP Commands Table 11-7 FTP commands Command Parameter 1 Parameter 2 LOG.TXT Storage location on the PC and file name (example: D:¥LOG.TXT) DUMP.TXT Storage location on the PC and file name (example: D:¥DUMP.TXT) CAPTURE.BMP Storage location on the PC and file name (example: D:¥CAPTURE.BMP) CAP_***.FRM Storage location on the PC and file name...
11. ETHERNET REMOTE CONTROL 11.3 SNMP By using SNMP (Simple Network Management Protocol), you can control an LV 5770 from SNMP managers. Additionally, you can notify the SNMP managers of errors that the LV 5770 generates. The LV 5770 supports SNMPv1. 11.3.1...
Page 142
[Enable (3) or disable (2) TRAP transmission destination 1] 1.3.6.1.4.1.leader(20111).lv5770(21).lv5770ST1(1).l21trapTBL(9).l21trapIpTBL(2).l21tr apIp3TBL(3).l21trapManagerIp3Act(2).0 [Enable (4) or disable (2) TRAP transmission destination 1] 1.3.6.1.4.1.leader(20111).lv5770(21).lv5770ST1(1).l21trapTBL(9).l21trapIpTBL(2).l21tr apIp4TBL(4).l21trapManagerIp4Act(2).0 Restart the LV 5770. 10. When the LV 7800 starts, it transmits the standard TRAP "coldStart(0)." Check that this is received by the SNMP managers.
11. ETHERNET REMOTE CONTROL 11.3.3 Standard MIB The LV 5770 uses the following standard MIBs: • RFC1213 (MIB-II) • RFC1354 (IP Forwarding Table MIB) In the tables, "ACCESS" and "SUPPORT" indicate the following: Indication Description ACCESS Information that can be read from the SNMP managers.
11. ETHERNET REMOTE CONTROL 11.3.4 Enterprise MIB ● Enterprise Number The Enterprise Number of LEADER ELECTRONICS CORP. is 20111. iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).leader(20111) ● Enterprise MIB File Download the enterprise MIB file using FTP. The file name is "lv5770.my." (Example: GET LV5770.MY D:¥LV5770.MY) ●...
Page 149
11. ETHERNET REMOTE CONTROL Table 11-15 l21basicTBL(1) group SYNTAX ACCESS VALUE/RANGE l21basInputTBL l21basicTBL.1 Aggregate l21basInputUnit l21basInputTBL.1 INTEGER 1 = Sdi 2 = Analog Composite l21basInputCh l21basInputTBL.2 INTEGER 1 = A 2 = B 3 = AB l21basInputSimul l21basInputTBL.3 INTEGER 1 = Off 2 = On l21basInputStream l21basInputTBL.4...
Page 167
11. ETHERNET REMOTE CONTROL SYNTAX ACCESS VALUE/RANGE l21staAncPktAribNetqBitQ14 l21staAncPktTBL.24 INTEGER 1 = On 2 = Off l21staAncPktAribNetqBitQ15 l21staAncPktTBL.25 INTEGER 1 = On 2 = Off l21staAncPktAribNetqBitQ16 l21staAncPktTBL.26 INTEGER 1 = On 2 = Off l21staAncPktAribNetqBitQ17 l21staAncPktTBL.27 INTEGER 1 = On 2 = Off l21staAncPktAribNetqBitQ18 l21staAncPktTBL.28...
Page 168
11. ETHERNET REMOTE CONTROL SYNTAX ACCESS VALUE/RANGE 2 = Off l21staAncPktAribNetqBitS5 l21staAncPktTBL.47 INTEGER 1 = On 2 = Off l21staAncPktAribNetqBitS6 l21staAncPktTBL.48 INTEGER 1 = On 2 = Off l21staAncPktAribNetqBitS7 l21staAncPktTBL.49 INTEGER 1 = On 2 = Off l21staAncPktAribNetqBitS8 l21staAncPktTBL.50 INTEGER 1 = On 2 = Off l21staAncPktAribNetqBitS9...
Page 169
11. ETHERNET REMOTE CONTROL SYNTAX ACCESS VALUE/RANGE 2 = Off l21staErrorSdiHdCrc l21staErrorSdiTBL.4 INTEGER 1 = On 2 = Off l21staErrorSdiSdEdh l21staErrorSdiTBL.5 INTEGER 1 = On 2 = Off l21staErrorSdiIllegalCode l21staErrorSdiTBL.6 INTEGER 1 = On 2 = Off l21staErrorAncTBL l21statusTBL.10 Aggregate l21staErrorAncParity l21staErrorAncTBL.1 INTEGER...
Page 170
11. ETHERNET REMOTE CONTROL SYNTAX ACCESS VALUE/RANGE 2 = Off l21staErrorFreezeUpper l21staErrorFreezeTBL.2 INTEGER 0 to 100 l21staErrorFreezeLower l21staErrorFreezeTBL.3 INTEGER 0 to 100 l21staErrorFreezeLeft l21staErrorFreezeTBL.4 INTEGER 0 to 100 l21staErrorFreezeRight l21staErrorFreezeTBL.5 INTEGER 0 to 100 l21staErrorFreezeDuration l21staErrorFreezeTBL.6 INTEGER 2 to 300 l21staErrorBlackTBL l21statusTBL.14 Aggregate...
Page 171
11. ETHERNET REMOTE CONTROL SYNTAX ACCESS VALUE/RANGE 3 = Cyan 4 = Green 5 = Magenta 6 = Red 7 = Blue l21eyeColorScale l21eyeColorTBL.2 INTEGER 1 = White 2 = Yellow 3 = Cyan 4 = Green 5 = Magenta 6 = Red 7 = Blue l21eyeGainTBL...
11. ETHERNET REMOTE CONTROL 11.3.5 Extended TRAP (Variable Binding List) ● index 1 OID: leader(20111).lv5770(21).lv5770ST1(1).trapTBL(9).trapStrTBL(1).1.0 Syntax: Counter Range: 1 to 4294967295 (overflow occurs if this range is exceeded) Description: The total number of enterprise traps sent after starting up ●...
Page 189
11. ETHERNET REMOTE CONTROL Specific Trap Type Indication Description LVL_Y_ERR Luminance level error detection LVL_C_ERR Chroma level error detection None (displayed in format information) Unsupported input signal format or an input signal format that is different from the specified format None (displayed in format information) No error (at error recovery, at startup) A_PRTY_ERR...
11. ETHERNET REMOTE CONTROL 11.4 HTTP Server Feature You can use this feature to control the LV 5770 from a web browser on a PC in the same manner as you would control the LV 5770 from the panel. 11.4.1 Operating Environment The following web browsers have been confirmed to work.
Page 191
Press F•1 COMPLETE. The message “Saving data - Please Wait” is displayed. If you changed the IP address, after the message disappears, restart the LV 5770. The IP address value is now valid. Connect the LV 5770's Ethernet port to the network.
Page 192
F・D as pressing the corresponding control on the LV 5770. On tab menus and some screens, -50 operates as -5 and +50 operates as +5. Also, in places where the setting resolution is a value other than 1, the value that is set is “resolution ×...
Page 193
The timing at which the function menus disappear is different between the LV 5770 and the browser, so when you control a function menu in the browser, the corresponding response may not be what you would expect. In this situation, set MENU Auto Off to a long time in the system menu.
11. ETHERNET REMOTE CONTROL 11.5 SNTP Client Function The LV 5770 can display time that is synchronized to an NTP server on the network. 11.5.1 Procedure Configure the Ethernet settings on the LV 5770's ETHERNET SETUP tab. Set SNTP Client Select to ON, and set the IP address, server IP address, and time zone adjustment.
11. ETHERNET REMOTE CONTROL 11.5.2 Time Adjustment Value The date and time exchanged with an NTP (SNTP) are basically Coordinated Universal Time (UTC). Therefore, the time must be adjusted in accordance with the country or region where the device is used in. On the ETHERNET SETUP tab, set Time Zone Adjust to one of the following values.
The default settings are underlined. The settings selected in the tab menu displays are also default settings. The menus that are displayed vary depending on the LV 5770 settings and whether a USB memory device is connected to the LV 5770.
Page 197
12. MENU TREES TAB 1 (SDI FORMAT) TAB 2 (REAR PANEL SETUP) TAB 3 (GENERAL SETUP)
Page 198
12. MENU TREES TAB 4 (ETHERNET SETUP) TAB 5 (REMOTE SETUP) TAB 6 (DATE&TIME)
12. MENU TREES 12.2 Capture Menu REFRESH ( MANUAL / ERROR ) REFRESH DISPLAY ( REAL / HOLD / BOTH ) FILE ( ON / OFF ) TYPE ( ON / OFF ) ( ON / OFF ) ( ON / OFF ) ( ON / OFF ) menu STORE...
12. MENU TREES 12.3 Preset Registration Menu COMMENT CLEAR INPUT DELETE INSERT <= => CHAR SET menu OVER WR STORE OVER WR DELETE DELETE DELETE ALL COPY COPY USB->INT COPY ALL COPY COPY INT->USB COPY...
• [LV 5770SER08 and LV 5770SER09A] A measurement range setting function was added to the lip sync measurement of the status display. Ver. 5.4 • [LV 5770] Recall menu was improved so that each time the RCLL key is pressed, the menu toggles between show and hide. Ver. 5.2 •...
Page 203
• [LV 5770SER08 and LV 5770SER09] Support has been added for HD dual link 1080p/60, 1080p/59.94, and 1080p/50. Ver. 1.6 • [LV 5770] 16:9 and 16:10 squeeze output features have been added to the DVI-D connector. • [LV 5770SER08 and LV 5770SER09] An AFD feature has been added to the picture aspect marker.
Page 204
INDEX ALL COPY INT->USB ..........97 LCD OFF ..............81 ALL COPY USB->INT ..........98 LICENSE SETUP ............81 ANALOG AUDIO ............49 MEM ..............94, 96 BMP ................85 MULTI .................57 BSG ................85 PIC MONI OUTPUT ...........44 CAP ................83 COMMENT INPUT ............
Page 205
Following information is for Chinese RoHS only 所含有毒有害物质信息 部件号码: LV 5770/5770A/SER03/SER03A/SER08/ SER09/SER09A/SER41/SER42/SER43 此标志适用于在中国销售的电子信息产品,依据2006年2月28日公布的 《电子信息产品污染控制管理办法》以及SJ/T11364-2006《电子信息产品污染 控制标识要求》,表示该产品在使用完结后可再利用。数字表示的是环境保护使 用期限,只要遵守与本产品有关的安全和使用上的注意事项,从制造日算起在数 字所表示的年限内,产品不会产生环境污染和对人体、财产的影响。 产品适当使用后报废的方法请遵从电子信息产品的回收、再利用相关法令。 详细请咨询各级政府主管部门。 产品中有毒有害物质或元素的名称及含量 有毒有害物质或元素 Hazardous Substances in each Part 部件名称 Parts 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr(Ⅵ)) (PBB) (PBDE) 实装基板...
Need help?