5.7 Power-On Process

_________________________ Caution __________________________
___________________________________________________________
Table 5-3 explains what happens during each phase of the DLT2700 operation.
Phase
What Happens
1.
When you power on the DLT2700, the Loader Fault and Power On lights
on the loader OCP are on.
2.
One second later, all lights are on. Within 15 seconds, POST of the
loader mechanics completes.
= If the Magazine Fault and Loader Fault lights turn off, loader POST
= If the Magazine Fault and Loader Fault lights stay on, loader POST
3.
A few seconds later, the drive controller resets the loader.
4.
Loader POST starts again.
_________________________ Note _____________________________
___________________________________________________________
5.
The elevator scans the magazine to determine which slots contain
cartridges.
Configuring and Operating the DLT2700 Mini-Library
Before applying power, verify the DLT2700 is set (see the
label on the mini-library rear panel) for the available ac
supply voltage.
Table 5-3 Loader Power-On Self-Test
succeeded.
failed.
If
The Magazine Fault and Loader Fault lights
turn off and shortly after, all OCP lights but
Power On turn off
The Magazine Fault and Loader Fault lights
stay on
If the Magazine Fault or Loader Fault lights remain on, POST
detected an error. See Chapter 6 for error conditions.
DLT2000/DLT2500/DLT2700 Cartridge Tape Subsystem 5-15
Then POST
Passed
Failed