Technical Specifications
Table A-20 list the conducted emission limits.
Frequency Range (MHz)
0.15 to 0.050
0.50 to 5
5 to 30
*The limit decreases with the logarithm of the frequency.
A.6.3 Radiated Emissions
Limits of radiated interference field strength, in the frequency range from 30 MHz to 30
GHz at a test distance of 3 and 10 meters, for Class B equipment are listed in table A-
21.
Table A-21 Radiated Emissions, 30 Mhz to 30 Ghz
Frequency range (MHz)
30 to 230
230 to 1000
Above 1000

A.6.4 Magnetic Radiated Susceptibility

Table A-22 lists the magnetic radiated susceptibility limits.
Table A-22 Low Frequency, Magnetic Fields, 10 to 3000 kHz
100 dB (pt) @ 10 kHz declining to
80 dB (pt) @ 1 MHz
A-20 DLT2000/DLT2500/DLT2700 Cartridge Tape Subsystem
Table A-20 Conducted Emissions
Quasi-peak
66 to 56*
56
60
Quasi-peak limit dB (µV/m)
@ 10 m
30
37
N/A
No errors, no screen distortion
Limits dB
Average
56 to 46
46
50
@ 3 m
40
46
54