Eaton CEAG 28011 Mounting And Operating Instructions

Eaton CEAG 28011 Mounting And Operating Instructions

Led cgline+ 1-8h/d

Advertisement

Quick Links

CEAG 28011/-21 LED CGLine+ 1-8h/D
Montage- und Betriebsanleitung
Mounting and Operating Instructions
Zielgruppe: Elektrofachkraft
Target group: Skilled electricians
Verwendungszweck: Notbeleuchtung, nicht für privaten Gebrauch
Intended Application: Emergency Lighting, not suitable for private use

Advertisement

Table of Contents
loading

Summary of Contents for Eaton CEAG 28011

  • Page 1 CEAG 28011/-21 LED CGLine+ 1-8h/D Montage- und Betriebsanleitung Mounting and Operating Instructions Zielgruppe: Elektrofachkraft Target group: Skilled electricians Verwendungszweck: Notbeleuchtung, nicht für privaten Gebrauch Intended Application: Emergency Lighting, not suitable for private use...
  • Page 2: Table Of Contents

    10 Disposal / Recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Manual CEAG 28011/-21 LED CGLine+ 1-8h/D 40071860278(B) January 2017 www.ceag.de...
  • Page 3: Normenkonformität

    60 598-2-22 und DIN EN 1838. Gemäß DIN and DIN EN 1838. EN ISO 9001 entwickelt, gefertigt und geprüft. Developed, manufactured and tested in ac- cordance with DIN EN ISO 9001. Manual CEAG 28011/-21 LED CGLine+ 1-8h/D 40071860278(B) January 2017 www.ceag.de...
  • Page 4: Kurzbeschreibung / Verwendungsbereich

    Leuchten dient dieser als Funktions- erde. geschaltetes Bereitschaftslicht Dauerlicht ohne, Dauerlicht switched mit Brücke maintained light zwischen L u. L ’ non maintained light without and maintained light with jumper L and L ’ Manual CEAG 28011/-21 LED CGLine+ 1-8h/D 40071860278(B) January 2017 www.ceag.de...
  • Page 5 Lebensdauer bitte das Inbetriebnahme-Datum in das auf der Batterie vorgesehene Feld ein- tragen! Taster/LED-Folien-Anschluss Beim Wechsel von Taster/LED oder Leiterkarte bitte Markierung 1 auf der Leiterkarte und auf der Leiterbahnfolie beachten! Manual CEAG 28011/-21 LED CGLine+ 1-8h/D 40071860278(B) January 2017 www.ceag.de...
  • Page 6 Duration 3 h / AUTO DT ON LED-Anschluss / LED-connection Testtaster-Anschluss / connection for test button Busanschluss siehe Kapitel 7 .1 / bus connection see chapter 7 .1 Netzanschluss / mains connection Manual CEAG 28011/-21 LED CGLine+ 1-8h/D 40071860278(B) January 2017 www.ceag.de...
  • Page 7: Leuchtenaufbau

    Style Variant 28021 LED CGLine+ (Bestellnr./order no. 400 71 354 816) Schnapphaken/ snap hooks Batterie/ battery Abdeckung/ cover Leiterkarte mit Anschlüssen/ printed circuit board Leiste mit with connections 2x2 Highpower LEDs/ light strip with 2x2 highpower LEDs Manual CEAG 28011/-21 LED CGLine+ 1-8h/D 40071860278(B) January 2017 www.ceag.de...
  • Page 8: Maßbilder

    5 Maßbilder / Dimensional drawings Style Variant 28011 LED CGLine+ 30 30 30 Style Variant 28021 LED CGLine+ 28021 LED CGLine+ mit Deckenbefestigung (Zubehör) 28021 LED CGLine+ with ceiling mounting (accessory) 198 218 Manual CEAG 28011/-21 LED CGLine+ 1-8h/D 40071860278(B) January 2017 www.ceag.de...
  • Page 9: Installation / Inbetriebnahme

    When connecting the LED modules please observe the polarity. Connect battery to the printed circuit board. Set operation mode (see chapter Attach the top enclosure with 4 screws and mount pictogram cover. Manual CEAG 28011/-21 LED CGLine+ 1-8h/D 40071860278(B) January 2017 www.ceag.de...
  • Page 10 Connect mains cable and bus cable. When connecting the LED modules please observe the polarity. Connect battery to the printed circuit board. Set operation mode (see chapter Attach the cover and mount pictogram cover. Manual CEAG 28011/-21 LED CGLine+ 1-8h/D 40071860278(B) January 2017 www.ceag.de...
  • Page 11: Einstellung Der Betriebsart

    Zeitpunkt des BTs in die Betriebszeit night, this should avoid the duration of the du- des Gebäudes fällt. ration test falling within the operating time of the building. Manual CEAG 28011/-21 LED CGLine+ 1-8h/D 40071860278(B) January 2017 www.ceag.de...
  • Page 12: Dimmlevel

    ändert werden. Bei jedem Tastendruck wird die hightest step is reached it begins again with the Helligkeit um eine Stufe erhöht. Ist die höchste lowest. Stufe erreicht, wird wieder bei der Niedrigsten begonnen. Manual CEAG 28011/-21 LED CGLine+ 1-8h/D 40071860278(B) January 2017 www.ceag.de...
  • Page 13: Test Und Anzeigeeinheit

    Funktionstest starten / start function test 5 - 10 Betriebsdauertest starten / stoppen / Start / stop duration test 10 - 20 Reset der Leuchte / Reset of the luminaire Manual CEAG 28011/-21 LED CGLine+ 1-8h/D 40071860278(B) January 2017 www.ceag.de...
  • Page 14 über die drei LEDs an der see operating instructions of a the central CG- Leuchte abgefragt werden kann. Line+ monitoring system. Weitere Informationen zur Adressierung siehe Betriebsanleitung der zentralen CGLine+ Überwa- chungseinrichtung. Manual CEAG 28011/-21 LED CGLine+ 1-8h/D 40071860278(B) January 2017 www.ceag.de...
  • Page 15: Technische Daten

    2006/66/EG - beim Wechsel an den Vertreiber oder an cordance with the 2006/66/EC directive. einen zugelassenen Entsorger zurück zu geben und darf nicht selbst entsorgt werden! Manual CEAG 28011/-21 LED CGLine+ 1-8h/D 40071860278(B) January 2017 www.ceag.de...
  • Page 16 Erfolg unserer Kunden stets an erster Stelle stehen. Für mehr Informationen besuchen Sie www.eaton.de. Ihre Ansprechpartner finden Sie unter www.ceag.de. At Eaton, we’re energized by the challenge of powering a world that demands more. With over 100 years experience in electrical power management, we have the expertise to see beyond today.

This manual is also suitable for:

Ceag 28021