DOCUMENT 2623 REV. H Instruction Manual Style II FAA Approach Fixture Revisions Issue/Reissue Revision Description Created/Updated Checked Approved Letter Number A206-218 INITIAL RELEASE 6/23/06 7.1, deleted fixture fits on L- A206-433 867 base & also added do not 11/9/06 install on shallow base 9.3, Take care not to damage mating surface.
DOCUMENT 2623 REV. H Instruction Manual Style II FAA Approach Fixture Product Warranty Warranty Refer to Eaton’s Crouse-Hinds Airport Lighting Products Terms and Conditions for product specific warranty information.
DOCUMENT 2623 REV. H Instruction Manual Style II FAA Approach Fixture 3.0 Warning Labels DANGER: DANGER The hazard or unsafe practice will result in severe injury or death. WARNING: WARNING The hazard or unsafe practice could result in severe injury or death. CAUTION: CAUTION The hazard or unsafe practice could result in minor injury.
DOCUMENT 2623 REV. H Instruction Manual Style II FAA Approach Fixture Safety Notices This equipment is normally used or connected to circuits that may employ voltages that are dangerous and may be fatal if accidentally contacted by operating or maintenance personnel. Extreme caution should be exercised when working with this equipment.
DOCUMENT 2623 REV. H Instruction Manual Style II FAA Approach Fixture 7 General Description 7.1 FAA Approach Light The Crouse-Hinds FAA Approach Light is a Style II, (≤1/2 inch) fixture that meets the photometric requirements of FAA-E-2952, FAA-E-2968 and L-850E with the appropriate lamp(s) and colored lens/lenses installed.
DOCUMENT 2623 REV. H Instruction Manual Style II FAA Approach Fixture Installation The style 2 FAA light units are shipped complete and are ready for installation as received. Installation of a light unit is to be done with primary POWER OFF and SECURED. At each light location, install a steel, Size B, 24 inch deep minimum, L-868 Light Base per FAA AC 150/5340-4 (latest revision).
DOCUMENT 2623 REV. H Instruction Manual Style II FAA Approach Fixture Maintenance The preferred method of maintaining these lights is to periodically and systematically replace the units and return them to the maintenance shop for renovation. As an alternative, the units can be serviced in the field.
DOCUMENT 2623 REV. H Instruction Manual Style II FAA Approach Fixture O-Ring Replacement Every time the unit is opened, the o-ring must be closely examined and replaced, if necessary. Any o-ring that is stretched, torn, has permanent set, or some other defect, which would prevent it from forming a watertight seal, must be replaced with a new o-ring.
DOCUMENT 2623 REV. H Instruction Manual Style II FAA Approach Fixture Lens Replacement If an outer lens is broken, leaks, or is badly pitted or scarred, it must be replaced. It is highly recommended that this task be performed in a clean shop environment. Lens Replacement Kit P/N 21480-X contains all necessary parts to change a lens.
DOCUMENT 2623 REV. H Instruction Manual Style II FAA Approach Fixture cover onto the light housing. The screw-hole patterns in the inner cover and light housing are offset to insure proper alignment. Torque the mounting screws to 30 in-lbs. Perform a pressure test per paragraph 9.6.
DOCUMENT 2623 REV. H Instruction Manual Style II FAA Approach Fixture Maintenance Program In order to insure maximum light fixture life, the installed units should be subject to a maintenance program in accordance with the following: A daily operation check should be made of the lighting fixture.
DOCUMENT 2623 REV. H Instruction Manual Style II FAA Approach Fixture Parts Lists ITEM NO. 8506A-XXX-P1 PART NUMBER DESCRIPTION SEE TABLE 21287 HOUSING, OPTICAL, ASS'Y,FAA APPROACH 21385 O-RING, SIZE #2-273, 70 DUROMETER, SILICONE, POST CURED SEE TABLE 21286 COVER, BOTTOM, ASS'Y, ICAO APPROACH SEE TABLE 21295 BRACKET, BASE, ASS'Y, ICAO APPROACH...
Page 17
DOCUMENT 2623 REV. H Instruction Manual Style II FAA Approach Fixture Figure 1: Exploded View of Fixture...
Page 18
DOCUMENT 2623 REV. H Instruction Manual Style II FAA Approach Fixture Figure 2: Isometric View of Fixture...
Page 19
DOCUMENT 2623 REV. H Instruction Manual Style II FAA Approach Fixture Figure 3: Top View of Fixture Figure 4: Side View of Fixture...
Page 20
DOCUMENT 2623 REV. H Instruction Manual Style II FAA Approach Fixture Figure 5: Bottom View of Fixture...
Page 21
DOCUMENT 2623 REV. H Instruction Manual Style II FAA Approach Fixture FEED-THRU REPLACEMENT INSTRUCTIONS 1. Torque item 3 to 30 in-lbs 2. Coat items 3, 4, 5 and lead terminals, on the outside of the cover only, with item 10. Allow to cure for 8 hours. 3.