INSTALLATION
Installation
f Screw the pre-assembled parts with flat gaskets to the cold
f
water and DHW pipes of the appliance.
f Fit the cold water inlet pipe and the DHW outlet pipe from
f
the pipework with flat gaskets to the extensions from the
appliance.
Making the electrical connection
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING Electrocution
Connection to the power supply is only permissible in the
form of a permanent connection in conjunction with the
removable cable grommet. Ensure the appliance can be
separated from the power supply by an isolator that dis-
connects all poles with at least 3 mm contact separation.
WARNING Electrocution
Ensure that the appliance is earthed.
Damage to the appliance and environment
!
Observe the type plate. The specified voltage must match
the mains voltage.
f Connect the power cable to the mains terminal (see chapter
f
"Specification / Wiring diagram"). The specified voltage must
match the mains voltage.
www.stiebel-eltron.com
Lower back panel installation
2
1
1 Connection pieces delivered in the pack
2 Screw
f Cut open the lower part of the back panel (see illustration).
f
f Fit the lower back panel by bending it out at the sides and
f
guiding it over the pipes.
f Insert the connection pieces into the lower back panel from
f
behind.
f Click the lower back panel into place.
f
f Align the mounted appliance by loosening the fixing toggle,
f
aligning the power supply and back panel, and then re-tight-
ening the fixing toggle.
f Secure the lower back panel with a screw.
f
DHB-E AU|