The Model 750EU Weight Indicator has been designed with an Event Counter type of security
seal. When selected, the 750EU will display two 3-digit numbers representing the Calibration
and Configuration counters.
Calibration Counter
The calibration counter is incremented when a value in the calibration part of setup is
changed (USA, int, Unit, UnS, dPP, CAP, FLt, F, br, Sr, CAL, SetGC, CALGC, OPGC).
The counter is only incremented 1 time even if more than one parameter is changed each
time through setup.
Configuration Counter
The configuration counter is incremented when a value in the configuration part of setup is
changed (Hold, bAnd, trA, PUO, niCAd, SLEEP, ASH). The counter is only incremented
1 time even if more than one parameter is changed each time through setup.
To Review the Event Counter:
1. If indicator is on, press ON / OFF key.
2. Display will show oFF and indicator will turn off.
3. Press and hold the UNITS key and then press ON / OFF key.
4. The display will then show CAL CH (Calibration Check) for two (2) seconds followed by
two 3-digit numbers.
• The left number represents the setup Configuration counter.
• The right number represents the Calibration counter.
5. To return to the normal operation, press the UNITS key.
6. Otherwise press the ON / OFF key to turn off the indicator.
EVENT COUNTER
8555-M260-O1 Rev J • 750EU Owner's
19