SETUP AND CALIBRATION, CONT.
F= (FILTER LEVEL)
Press the BMI / ENTER key to view the current setting. If the value displayed is acceptable,
press the BMI / ENTER key again. Otherwise, press the  or  keys to scroll through and
select a new value and then press the BMI / ENTER key to save it and proceed to the next
prompt. Allowable values are 1 (least amount of filtering) to 99 (greatest amount of filtering).
BR= (BREAK RANGE)
Press the BMI / ENTER key to view the current setting. If the value displayed is acceptable,
press the BMI / ENTER key again. Otherwise, press the  or  keys to scroll through and
select a new value and then press the BMI / ENTER key to save it and proceed to the next
prompt. Allowable values are 1 to 99 which correspond to the number of division changes
to break out of filtering.
SR= (SAMPLE RATE)
Press the BMI / ENTER key to view the current setting. If the value displayed is acceptable,
press the BMI / ENTER key again. Otherwise, press the  or  keys to scroll through and
select a new value and then press the BMI / ENTER key to save it and proceed to the next
prompt. Allowable values are a minimum of 1 sample per second to a maximum of 16
samples per second in one sample per second intervals.
CAL= (CALIBRATION)
With the display showing CAL=, press the BMI / ENTER key. The display will change to
show the current setting 0 (0=NO). If the scale has been previously calibrated and you wish
to skip calibration and proceed to the HOLD= (Hold Mode) prompt, press the BMI / ENTER
key and the previous calibration will be retained.
To begin calibration, press the  key to select 1 (yes) and then press the BMI / ENTER key.
After pressing the BMI / ENTER key, the display will change to LOAd=.
LoAd= (LOAD CALIBRATION WEIGHT)
With the display showing LoAd= perform the following steps:
1. Make certain the scale platform is empty and free of debris.
2. Place the desired amount of calibrated test weights on the scale platform. A minimum
of 50% of scale's capacity is required. However 70% to 100% is recommended.
3. Press the BMI / ENTER key.
4. If the value displayed is acceptable, press the BMI / ENTER key again. Otherwise,
determine the exact amount of test weight placed on the scale platform and then using
the  or  keys and the  or  keys scroll through and select the test weight amount.
5. Verify that the numbers selected are the same as the amount of the test weight and
then press the BMI / ENTER key.
6. Starting at the left and preceding right, a series of dashes will appear on the display.
The dashes will stay on the display momentarily, then disappear, after which the display
will proceed to the next prompt.
8555-M260-O1 Rev J • 750EU Owner's