Detecto 750EU Owner's Manual page 19

Weight indicator with body mass index features
Table of Contents

Advertisement

SETUP AND CALIBRATION, CONT.
HoLd= (HOLD MODE)
Press the BMI / ENTER key to view the current setting. If the value displayed is acceptable,
press the BMI / ENTER key again. Otherwise, press the  or  keys to scroll through and
select a new value and then press the BMI / ENTER key to save it and proceed to the next
prompt. Allowable values are: 0, 1, or 2.
0 = NO (disable)
• If HoLd=0 or1 (NO or YES) is selected, proceed to tra= (Zero Tracking Range) prompt.
• If HoLd=2 (AUTO) is selected, an additional prompt bAnd= (Auto Lock Reset Band) will
be displayed. Proceed to bAnd= prompt to continue setup.
With Hold feature enabled (HoLd=1), the indicator will lock the displayed weight on the
display when LOCK/RELEASE key is pressed. Pressing the key again will unlock display. If
automatic hold (HoLd=2) is selected, the indicator will automatically lock the weight on the
display after obtaining a stable weight value that exceeds the Auto Lock Reset Band value.
Refer to Auto Lock Reset Band setup below.
NOTE! The HOLD mode of operation is only used in non-commercial
applications and must be DISABLED (set to 0 = NO) for "Legal for Trade"
applications.
bAnd= (AUTO LOCK RESET BAND)
If Auto Lock is selected, the display will change to show the bAnd= (Auto Lock Reset Band)
prompt. This is the number of division changes needed to reset the auto lock. For the Auto
Lock to function, the load on the scale must rise above the bAnd= value (and remain
stable). To release Auto Lock, the load on the scale must fall below the bAnd= value. At
that point, the next weighing operation can begin.
Press the BMI / ENTER key to view the current setting. If the value displayed is acceptable,
press the BMI / ENTER key again. Otherwise, press the  or  keys and the  or  keys to
scroll through and select a new value and then press the BMI / ENTER key to save it and
proceed to the next prompt. Allowable values are: 0 through 99.
trA= (ZERO TRACKING RANGE)
Zero tracking range is a value in scale divisions that will be automatically zeroed off. Press
the BMI / ENTER key to view the current setting. If the value displayed is acceptable, press
the BMI / ENTER key again. Otherwise, press the  or  keys and the  or  keys to scroll
through and select a new value and then press the BMI / ENTER key to save it and proceed
to the next prompt. Allowable values are 1 through 18 (1 to 9 divisions by 0.5 divisions).
Select 0 (zero) to disable zero tracking.
PUO= (Power Up Zero)
Press the BMI / ENTER key to view the current setting. If the value displayed is acceptable,
press the BMI / ENTER key again. Otherwise, press the  or  keys to scroll through and
select a new value and then press the BMI / ENTER key to save it and proceed to the next
prompt. Allowable values are: 0 or 1.
PUO=1 (YES)
Weight display will be reset to
zero automatically on power up
1 = YES (enable)
PUO=0 (NO)
weight display will not be reset to zero
8555-M260-O1 Rev J • 750EU Owner's
2 = AUTO (Automatic Hold)
15

Advertisement

Table of Contents
loading

Table of Contents