TROUBLESHOOTING

Perturbations
Abnormal heavy vibrations
Wire breakage
Noise in the pole
Tool does not start
Tool suddenly stops
Causes
Wrong tightening of the brush
Detect faulty tool.
Wear
Deteriorated pole guide
Battery drained
No power to the tool
Others
Battery drained
15
Solutions
Contact your dealer
Contact your dealer
Change the worn wire
Contact your dealer
Recharge the battery
Reconnect to power source
Contact your dealer
Recharge the battery