Dismantling And Disposal; Safety Notes For Dismantling And Disposal; Dismantling - Linde HiQ R200 Instructions For Use Manual

4-/ 6-port line regulator
Table of Contents

Advertisement

Available languages

Available languages

Description
No changes of
valve control
when turning
the handwheel
EN
Moisture on
pressure regu-
lator (NO dew,
rain or snow)
Icing on pres-
sure regulator
(NO dew, rain
or snow)
This table is not exhaustive. For questions and ambiguities please contact manufacturer.

10. DISMANTLING AND DISPOSAL

Once the system has reached its end-of-life, it must be dismantled and disposed of in an environmentally
compatible way.

10.1. SAFETY NOTES FOR DISMANTLING AND DISPOSAL

WARNING!
Risk of injury through incorrect dismantling!
RESIDUAL ENERGY STORAGE, SHARP EDGED COMPONENTS, TIPS AND CORNERS ON AND IN THE
SYSTEM OR ON THE REQUIRED TOOLS CAN CAUSE INJURY.
arrange enough space for working
be careful with sharp edges
pay attention for order and cleanness
loose components can cause accidents
dismantle the components properly. Bear in mind that some of the components are heavy. Use lifting
equipment if necessary
secure the components against falling or toppling over

10.2. DISMANTLING

PRIOR STARTING DISMANTLING
Depressurize the line regulator by turning the handwheel.
Depressurize tubing system and purge with inert gas if neccessary.
Dismantle the assemblies and components properly and in compliance with applicable local work safety and
environmental protection regulations. environmental protection regulations.
At the end devices and components have to be cleaned and disassembled due to valid rules of industrial
safety and environment protection.
Reason
Solution
Defect
Repair by
handwheel be-
manufacturer
cause of too
high torque,
defect of
spindle, defect
of thread
Pressure regu-
No failure, nor-
lator withdraw
mal operating
energy from
state
environment
through gas
expansion
Pressure regu-
No failure, nor-
lator withdraw
mal operating
energy from
state ATTEN-
environment
TION: keep
through gas
functionality of
expansion, lim-
contact gauges
ited delivery
in mind, raise
performance
quantity of
from pressure
pressure gas
gas tanks, e.g.
tanks
N2O, CO2
Valve
Cylinder
Regulator
20/44
Line
Gas
Regulator
Supply Panel