Summary of Contents for Radiant RBA CS 100 E

  • Page 1 User Manual for model RBA CS 100 E Floor standing storage combi cylinder room sealed chamber 0694 RBA CS 100 - RAD - ING - MAN.UT - 0807B - DIGITECH Documentazione Tecnica RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ITALIANO...
  • Page 3 The installation, first start-up, regulation and maintenance operations must be carried out exclusively by qualified personnel (e.g. Radiant authorised Service Centres). Incorrect installation can cause damage to property and injury to persons or animals, for which the manufacturer will not be held responsible.
  • Page 4 USER INSTRUCTIONS If you smell gas …  DO NOT ACTIVATE ANY ELECTRIC SWITCHES, TELEPHONES OR ANY OTHER DEVICE THAT MAY GENERATE ELECTRICAL DISCHARGES OR SPARKS.  OPEN DOORS AND WINDOWS IMMEDIATELY TO CREATE A CURRENT OF AIR THAT WILL RAPIDLY CLEAR THE ROOM.
  • Page 5 USER INSTRUCTIONS Starting - up the boiler  Open the gas Isolation valve located under the boiler.  Switch on the boiler by placing the ON/OFF switch (1) in the ON position (see “Control panel”).  The boiler will light automatically (with the WINTER mode selected...
  • Page 6 USER INSTRUCTIONS ■ D.H.W. temperature control The domestic hot water temperature is regulated by knob 3 (see “Control panel”).  Rotating knob anticlockwise reduces temperature.  Rotating knob clockwise increases temperature.  The range of temperature settings for the domestic hot water runs from a minimum of 35°C to a maximum of 60°C.
  • Page 7 USER INSTRUCTIONS _E12_ D.H.W boiler sensor malfunction Code E12 lit continuously on the display. Call the Service Centre. _E14_ Air Pressure Switch Tripped Code E14 lit continuously on the display. Call the Service Centre. _E22_ Parameter programming request Code E22 lit continuously on the display. Call the Service Centre. _E35_ Flame Detection Malfunction Code E35 lit continuously on the display.
  • Page 8 Via Pantanelli, 164/166 - 61025 Loc. Montelabbate (PU) Tel. +39 0721 9079.1 • fax. +39 0721 9079279 e-mail: tecnico@radiant • Internet: http://www.radiant.it THE TECHNICAL DATA AND MEASUREMENTS ARE PROVIDED FOR INFORMATION PURPOSES ONLY AND ARE NOT BINDING. THE COMPANY RESERVES THE RIGHT TO APPLY VARIATIONS WITHOUT PRIOR NOTIFICATION.