INSTALLATION,
AND MAINTENANCE MANUAL
FOR GAS FIRED, WALL-HUNG BOILERS
RSF 20 E – RSF 24 E
Model
TYPE C
ROOM SEALED
CE
0694
Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY
ENGLISH
By Technical Department

Advertisement

Table of Contents
loading

Summary of Contents for Radiant RSF 20 E

  • Page 1 INSTALLATION, AND MAINTENANCE MANUAL FOR GAS FIRED, WALL-HUNG BOILERS RSF 20 E – RSF 24 E Model TYPE C ROOM SEALED 0694 ENGLISH Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY By Technical Department...
  • Page 3: Table Of Contents

    INDEX INSTALLATION INSTRUCTIONS AND WARNINGS page TECHNICAL DATA page OVERALL DIMENSIONS - EXHAUST FLUE SYSTEM page GENERAL INSTALLATION REQUIREMENTS page BOILER INSTALLATION page ELECTRICAL CONNECTIONS page 8-16-17 BOILER CONTROL PANEL page STARTING UP THE BOILER FOR THE FIRST TIME page BOILER ADJUSTMENTS page GAS TYPE CONVERSION...
  • Page 4: Technical Data

    RADIANT BRUCIATORI S.p.A. products are type tested EC. All RADIANT boilers are constructed according to UNI - CIG (EC) norms. The materials used, such as copper, brass, and stainless steel form a compact, homogeneous, highly functional unit that is easy to install and simple to operate. The wall-mounted boiler is equipped with all of the approved accessories required to make it a true, independent heating plant for home heating and for the production of hot water for domestic needs.
  • Page 5 (air intake, combustion chamber, exchanger, combustion exhaust) is sealed off from the place where they are installed. CENTRAL HEATING - DOMESTIC HOT WATER sealed combustion circuit type RSF 20 E - electronic ignition Coaxial vertical C52 Double RSF 24 E - electronic ignition...
  • Page 6 C HOT WATER ½” F COLD WATER ½” A HEATING FLOW ¾” NOTE: USE ORIGINAL RADIANT APPROVED FLUE KIT SYSTEMS, FLUE ACCESSORIES AND FLUE DIAPHRAGMS ONLY. APPROVED RADIANT FLUE DIAPHRAGMS AND ADJUSTMENT TABLES ARE SUPPLIED WITH RADIANT ORIGINAL FLUE KIT SYSTEMS.
  • Page 7: General Installation Requirements

    Installation Manual GENERAL INSTALLATION REQUIREMENTS GAS SAFETY It is the law that all gas appliances are installed by a CORGI registered installer (you can check this by contacting corgi on 01256.372200) in accordance with the regulations listed below. Failure to install appliances correctly could lead to prosecution. It is in your own interest and that of safety to ensure that the law is complied with.
  • Page 8 Installation Manual FLUE POSITION IMPORTANT: THE FLUE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE RECOMMENDATIONS CONTAINED IN BS 5440:1. The boiler MUST be installed so that the terminal is exposed to the external air. It is important that the position of the terminal allows free passage of air across it at all times. If the terminal discharges into a pathway or passageway check that combustion products will not cause nuisance and that the terminal will not obstruct the passageway.
  • Page 9 Installation Manual MINIMUM DISTANCES FOR FIXING TO WALL Fig. 2 60 450 MINIMUM DISTANCES mm. Fig. 1 FIXING JIG To allow access in the boiler for maintenance operations, the minimum distances W/VALVES shown below must be respected (fig. 1): To facilitate installation, the boiler is supplied with a template for advance location of Fig.
  • Page 10 ANTI-FREEZE SYSTEM ANTI-FROST SYSTEM Radiant boilers are equipped with an Anti-Freeze system which comes into operation when the temperature falls to 5° C (Heating sensor) and 4° C (Hot water sensor) and protects the boiler down to –2°C external temperature.
  • Page 11 Installation Manual ELECTRICAL CONNECTIONS Fig. 1 The boiler works with 230 V 50 Hz AC current and has maximum input of 170 W. Connection to the electrical mains must be performed with a device having an omnipolar opening of at least 3 mm.
  • Page 12 Installation Manual CONTROL PANEL LEGEND (see fig. 1) 1. SUMMER-WINTER ON-OFF SWITCH 2. LOCK-OUT INDICATOR 3. HEATING TEMPERATURE ADJUSTMENT KNOB 4. WATER TEMPERATURE ADJUSTMENT KNOB 5. SPACE FOR ADDING AN OPTIONAL TIMER SELF- DIAGNOSTIC LEGEND (see fig. 2) 6. OPERATING/ POWER INDICATOR 7.
  • Page 13: Boiler Adjustments

    Installation Manual • check the pressure in the system: if this has gone down and LED 13 (see fig. 2 pag. 9) comes restore pressure; • close the tap on the filling loop once this operation is completed; Starting up the boiler •...
  • Page 14: Boiler Adjustments

    Installation Manual BOILER ADJUSTMENTS SELECTOR FUSE 1 RL3-RT RL1-RP LINK PTC1 RLA - CM1 RL2-RS SELECTOR RL4-RV P1 SAN. RISC. T. RIS M. RIS LINK FASX2 FASX3 SELECTOR FASX1 FASX4 NATURAL GAS COMMUTATOR L.P.G. GPL-MET HEATING TIMER STARTING STEP RLA P4 MAXIMUM HEATING TRIMMER.
  • Page 15: Gas Type Conversion

    DATA TABLE Models: RSF 20 E NATURAL GAS G 20 LIQUID BUTAN GAS G 30 LIQUID PROPANE GAS G 31 Lower Wobbe index (15°C;...
  • Page 16: Regulating The Gas Pressure

    Installation Manual REGULATING THE GAS PRESSURE Maximum and minimum modulation pressures. N.B. The following operations must only be carried out by authorised personnel and are necessary when the boiler is converted to run on one type of gas or another or also in cases where the maximum pressure is not the same as that shown on the plate.
  • Page 17 Installation Manual TECHNICAL DATA DIFFERENTIAL AIR PRESSURE SWITCH FOR FAN CONTROL To guarantee maximum safety in flue exhaust, a differential pressure switch is installed on the Room Sealed Combustion Chamber Model (wall-mounted, room- sealed boilers) and on forced draught boilers. This pressure switch automatically Fig.
  • Page 18: Main Components

    For partial by-pass flows, use the adjuster screw. Fig. 1 MAIN COMPONENTS mod. RSF 20 E - RSF 24 E 1. FRAME 2. FLUE HOOD – ROOM SEALED COMBUSTION CHAMBER 3. COMBUSTION CHAMBER 4. ROOM SEALED CHAMBER COVER 5.
  • Page 19: Wiring Diagram

    Installation Manual ELECTRICAL CONNECTION FOR ROOM SEALED COMB. CHAMBER ELECTRONIC IGNITION BOILER – mod. RSF 20 E - RSF 24 E RAMIRE 3 CIRCUIT BOARD STANDARD ON ALL MODELS N.B. M1 CONNECTOR OF THE RAVI 2 CIRCUIT BOARD MUST BE CONNECTED TO...
  • Page 20 Installation Manual WIRING DIAGRAM FOR ROOM SEALED COMB. CHAMBER ELECTRONIC IGNITION BOILER – mod. RSF 20 E - RSF 24 E NET FILTER 80° 70° 60° 50° 40° 30° light-blue brown MAX. RIS TIMER RIS. RAVI2 brown SK06205 PTC2 T. RIS T.
  • Page 21: Maintenance

    Installation Manual MAINTENANCE To keep the boiler in efficient and safe operating condition, we recommend you perform the following checks at least once a year: • Check all seals on the gas side and replace gaskets to restore perfect seal as required. •...
  • Page 22 Installation Manual ELECTRONIC WATER PRESSURE GAUGE SELF-DIAGNOSTIC Fig. 2 Fig. 1 MALFUNCTION POSSIBLE CAUSE SOLUTION Light 6 (fig.2) is on but nothing works. water pressure switch replace it b. water pressure below 0.5 bar (light 14 fig. 2 load water flashing).
  • Page 23 Installation Manual SPARE PARTS SHORT LIST n° CODE DESCRIPTION RSF 20 E RSF 24 E Room Sealed Room Sealed Electronic Ignition Electronic Ignition 58006LP MAIN HEAT EXCHANGER Mod. 20.000 - 63 A 58007LP MAIN HEAT EXCHANGER Mod. 24.000 - 66 A...
  • Page 24 • Internet: http://www.radiant.it UK – Radiant Helpline – 01329.828555 All descriptions and illustrations contained in this leaflet have been carefully prepared but we reserve the right to make changes and improvements in our products whitch may affect the accurancy of the information contained in this leaflet. E + OE All rights reserved.