  • Page 1 HIGH SPEED BIPOLAR AMPLIFIER HSA42011 HSA42012 HSA42014 INSTRUCTION MANUAL NF Corporation...
  • Page 3 DA00086378-003 HIGH SPEED BIPOLAR AMPLIFIER HSA42011 HSA42012 HSA42014 INSTRUCTION MANUAL...
  • Page 5  Preface  Thank you for purchasing the HSA42011 / HSA42012 / HSA42014 high speed bipolar power amplifier. To ensure safe and proper use of this electric equipment, please read first Safety Precautions on the following pages.  Caution Symbols Used in This Manual caution symbols are used in this manual.
  • Page 6: Safety Precautions

     Safety Precautions  To ensure safe use, be sure to observe the following warnings and cautions. NF Corporation shall not be held liable for damages that arise from a failure to observe these warnings and cautions. This product is a Class 1 product (with protective conductor terminal) that conforms to the JIS and IEC insulation standards.
  • Page 7 Using the product in wet condition may cause electric shock and fire. When water etc. get into the product, immediately power it off, and contact NF Corporation or one of our representatives.  If lightning occurs, power off and disconnect this product.
  • Page 8 To protect the environment, follow the guidelines described below for the disposal of this product. a) Use the services of an industrial waste disposal contractor for disposal of the entire product. b) This product does not use batteries. c) This product does not contain mercury. HSA42011 / HSA42012 / HSA42014...
  • Page 9: Table Of Contents

    Increasing of Output Voltage by Balanced Output ..........4-5 TROUBLESHOOTING ........................5-1 Error Messages ....................... 5-2 5.1.1 Errors at Power-on ....................5-2 5.1.2 Errors Related to the Protection Function ............5-3 When Fault Symptoms Are Observed ..............5-5 HSA42011 / HSA42012 / HSA42014...
  • Page 10 7.11 Safety, EMC, and RoHS ..................7-6 7.12 Operating Environment ..................7-7 7.13 External Dimensions and Weight ................7-8 7.14 Option ........................7-8 7.15 Output Voltage / Current Range ................7-9 7.16 External Dimensions .................... 7-11 HSA42011 / HSA42012 / HSA42014...
  • Page 11 Figure 2-2. Rack mount bracket assembly diagram (JIS for HSA42011) ..2-7 Figure 2-3. Rack mount bracket assembly diagram (EIA for HSA42012)..2-8 Figure 2-4. Rack mount bracket assembly diagram (JIS for HSA42012) ..2-9 Figure 2-5. Rack mount bracket assembly diagram (EIA for HSA42014)..2-10 Figure 2-6.
  • Page 12 Figures Figure 7-2. HSA42011 Output Voltage / Current Range ........7-9 Figure 7-3. HSA42012 Output Voltage / Current Range ........ 7-10 Figure 7-4. HSA42014 Output Voltage / Current Range ........ 7-10 Figure 7-5. HSA42011 External Dimensions ..........7-11 Figure 7-6. HSA42012 External Dimensions ..........7-12 Figure 7-7.
  • Page 13 Table 5-3. Errors Related to Protection Function (2/2)................5-4 Table 5-4. When Fault Symptoms Are Observed (1/2) ................5-5 Table 5-5. When Fault Symptoms Are Observed (2/2) ................5-6 Table 6-1. Judgment of HSA42011 / HSA42012 / HSA42014 Performance .......... 6-15 HSA42011 / HSA42012 / HSA42014...
  • Page 15: Overview

    1. OVERVIEW General ............... 1-2 Features .............. 1-3 Applications ............1-4 List of Functions ..........1-4 Principle of Operation .......... 1-5 HSA42011 / HSA42012 / HSA42014...
  • Page 16: General

    Constant voltage (CV) output characteristics are supported, and the rated output voltage and current are ±75 V and 1.06 Arms for HSA42011, 2.12 Arms for HSA42012 and 4.24 Arms for HSA42014, respectively.
  • Page 17: Features

    HSA42011 output impedance: [ 0.19 + 0.0155 f × (1 + j ) ]  or less (typ.) HSA42012 output impedance: [ 0.19 + 0.00803 f × (1 + j ) ]  or less (typ.) HSA42014 output impedance: [ 0.19 + 0.00460 f × (1 + j ) ]  or less (typ.) ...
  • Page 18: Applications

     For testing and characteristics analysis liquid crystals and so forth  For testing and characteristics analysis of micro actuators and so forth  For use as a booster amplifier for signal generators such as the WF series of NF Corporation ...
  • Page 19: Principle Of Operation

    LINE DCPS LINE FILTER OFFSET INPUT A INVERT OUTPUT FRONT 50Ω 10kΩ OUTPUT FIXED GAIN VAR GAIN POWER AMP REAR INPUT B BIAS MONITOR 50Ω 10kΩ PRE-AMP V METER I METER Figure 1-1. Block Diagram HSA42011 / HSA42012 / HSA42014...
  • Page 21: Preparations Before Use

    2. PREPARATIONS BEFORE USE Checking Before Use ........... 2-2 Installation ............2-3 Grounding and Power Supply Connection ..2-18 Simplified Operation Check ....... 2-19 Calibration ............2-22 Radio Law ............2-23 HSA42011 / HSA42012 / HSA42014...
  • Page 22: Checking Before Use

    After opening the corrugated box, check the items contained in the box. If an abnormality such as a flaw or dent is found on the product or an accessory is missing, contact NF Corporation or its representative.  Appearance check Check that no abnormalities such as a flaw and dent are found on the panel, controls, connectors, and so forth.
  • Page 23: Installation

     This product may malfunction.  Location exposed to excessive vibration  This product may malfunction or fail.  Location with excessive dust  In particular, electrically conductive dust may cause failure of this product. HSA42011 / HSA42012 / HSA42014...
  • Page 24: Figure 2-1. Rack Mount Bracket Assembly Diagram (Eia For Hsa42011)

    Figure 2-1. Rack mount bracket assembly diagram (EIA for HSA42011) Figure 2-2. Rack mount bracket assembly diagram (JIS for HSA42011) Figure 2-3. Rack mount bracket assembly diagram (EIA for HSA42012) Figure 2-4. Rack mount bracket assembly diagram (JIS for HSA42012) Figure 2-5.
  • Page 25 Make sure that there is at least 50 cm between the rear of this product and the inner wall of the rack. If the ambient temperature exceeds the specification or the air exhaust vent is blocked, the performance of this product may decrease or this product may be damaged. HSA42011 / HSA42012 / HSA42014...
  • Page 26 2.2 Installation Figure 2-1. Rack mount bracket assembly diagram (EIA for HSA42011) HSA42011 / HSA42012 / HSA42014...
  • Page 27 2.2 Installation Figure 2-2. Rack mount bracket assembly diagram (JIS for HSA42011) HSA42011 / HSA42012 / HSA42014...
  • Page 28 2.2 Installation Figure 2-3. Rack mount bracket assembly diagram (EIA for HSA42012) HSA42011 / HSA42012 / HSA42014...
  • Page 29 2.2 Installation Figure 2-4. Rack mount bracket assembly diagram (JIS for HSA42012) HSA42011 / HSA42012 / HSA42014...
  • Page 30 2.2 Installation Figure 2-5. Rack mount bracket assembly diagram (EIA for HSA42014) 2-10 HSA42011 / HSA42012 / HSA42014...
  • Page 31 2.2 Installation Figure 2-6. Rack mount bracket assembly diagram (JIS for HSA42014) 2-11 HSA42011 / HSA42012 / HSA42014...
  • Page 32 2.2 Installation Figure 2-7. Rack mount bracket dimensions (EIA for HSA42011) 2-12 HSA42011 / HSA42012 / HSA42014...
  • Page 33 2.2 Installation Figure 2-8. Rack mount bracket dimensions (JIS for HSA42011) 2-13 HSA42011 / HSA42012 / HSA42014...
  • Page 34 2.2 Installation Figure 2-9. Rack mount bracket dimensions (EIA for HSA42012) 2-14 HSA42011 / HSA42012 / HSA42014...
  • Page 35 2.2 Installation Figure 2-10. Rack mount bracket dimensions (JIS for HSA42012) 2-15 HSA42011 / HSA42012 / HSA42014...
  • Page 36 2.2 Installation Figure 2-11. Rack mount bracket dimensions (EIA for HSA42014) 2-16 HSA42011 / HSA42012 / HSA42014...
  • Page 37 2.2 Installation Figure 2-12. Rack mount bracket dimensions (JIS for HSA42014) 2-17 HSA42011 / HSA42012 / HSA42014...
  • Page 38: Grounding And Power Supply Connection

    50 Hz/60 Hz 2 Hz (single phase) Frequency range: Power consumption HSA42011: 290 VA or less HSA42012: 580 VA or less HSA42014: 1050 VA or less  Connect the power supply according to the following procedure: 1. Check that the commercial voltage supply to be connected is within the voltage range of this product.
  • Page 39: Simplified Operation Check

    0.5 Vrms or more (Load: 50  Signal generator Output voltage: WF1947 1 CH 30 MHz multifunction generator manufactured by NF Corporation, or equivalent Frequency bandwidth: 20 MHz or more Oscilloscope Use an oscilloscope that can measure 100 V or higher by...
  • Page 40: Figure 2-13. Standard Connection Diagram

    Setting INPUT Set A to ON. 50  50 GAIN INVT BIAS OFF (Dial scale: 5.00) Signal generator (WF1947) Item Setting Frequency (FREQ) 1 kHz Waveform (FUNCTION) Sine wave Output level (AMPTD) Offset (OFFSET) 2-20 HSA42011 / HSA42012 / HSA42014...
  • Page 41 0.71 2.00 5.00 8.00 9.29 Approx. Approx. Approx. Approx. Approx. Output 75 V 53 V +53 V +75 V Approx. Approx. Approx. Approx. Approx. Meter indication 75 V 53 V +53 V +75 V 2-21 HSA42011 / HSA42012 / HSA42014...
  • Page 42: Calibration

    A performance test should be conducted by a person who has a general knowledge of measuring instruments and is familiar with measuring instrument handling. 2-22 HSA42011 / HSA42012 / HSA42014...
  • Page 43: Radio Law

    The application forms and instructions can be obtained at the website of each Bureau of Telecommunications, as well as procedure details and information about other documents to be attached to the application forms. 2-23 HSA42011 / HSA42012 / HSA42014...
  • Page 44 Applications must be submitted by the person who installed the equipment, since information such as the installation location must be filled in. d) This product's external view drawings or photographs are required as attached documents. For any question or further information, contact an NF Corporation sales representative. 2-24 HSA42011 / HSA42012 / HSA42014...
  • Page 45: Panel Features And Basic Operations

    Fine Output Offset Adjustment ························ 3-15 3.5.4 DC Bias Addition ·········································· 3-16 3.5.5 Output Polarity Switching ······························· 3-16 3.5.6 Output Voltage Monitoring ······························ 3-17 3.5.7 Output on/off Control ···································· 3-18 Setting at Power-on ············································ 3-18 HSA42011 / HSA42012 / HSA42014...
  • Page 46: Panel Component Designations And Operations

    Error LED Overload LED 3.5.7 Output Current Polarity LED 3.5.6 Output on / off Switch 3.5.7 Output Connector 3.3.2 Bias Switch and Dial 3.5.4 Output Polarity Switch 3.5.5 Input Connector 3.3.1 Figure 3-1. HSA42011 Front Panel HSA42011 / HSA42012 / HSA42014...
  • Page 47: Figure 3-2. Hsa42012 Front Panel

    Error LED Overload LED 3.5.7 Output Current Polarity LED 3.5.6 Output on / off Switch 3.5.7 Output Connector 3.3.2 Bias Switch and Dial 3.5.4 Output Polarity Switch 3.5.5 Input Connector 3.3.1 Figure 3-2. HSA42012 Front Panel HSA42011 / HSA42012 / HSA42014...
  • Page 48: Figure 3-3. Hsa42014 Front Panel

    Error LED Overload LED 3.5.7 Output Current Polarity LED 3.5.6 Output on / off Switch 3.5.7 Output Connector 3.3.2 Bias Switch and Dial 3.5.4 Output Polarity Switch 3.5.5 Input Connector 3.3.1 Figure 3-3. HSA42014 Front Panel HSA42011 / HSA42012 / HSA42014...
  • Page 49: Rear Panel

    3.1 Panel Component Designations and Operations 3.1.2 Rear Panel Input Connector 3.3.1 DIP Switch Set at Power-on External Control I/O Connector 3.3.4 Output Connector 3.3.2 Power Inlet Monitor Output Connector 3.3.3,3.5.6 Figure 3-4. HSA42011 Rear Panel HSA42011 / HSA42012 / HSA42014...
  • Page 50: Figure 3-5. Hsa42012 Rear Panel

    3.1 Panel Component Designations and Operations Input Connector 3.3.1 DIP Switch Set at Power-on External Control I/O Connector 3.3.4 Output Connector 3.3.2 Power Inlet Monitor Output Connector 3.3.3, 3.5.6 Figure 3-5. HSA42012 Rear Panel HSA42011 / HSA42012 / HSA42014...
  • Page 51: Figure 3-6. Hsa42014 Rear Panel

    3.1 Panel Component Designations and Operations DIP Switch Set at Power-on External Control I/O Connector 3.3.4 Power Inlet Monitor Output Connector 3.3.3,3.5.6 Output Connector 3.3.2 Input Connector 3.3.1 Figure 3-6. HSA42014 Rear Panel HSA42011 / HSA42012 / HSA42014...
  • Page 52: Indications At Power-On And Initialization

    If this product cannot be operated after the power is turned on, a fault has occurred. Turn off the power immediately and then contact NF Corporation or its representative. For fault diagnosis at Power-on, refer to "5.1.1 Errors at Power-on".
  • Page 53: Output Connector (Main Output)

    1.06 Arms,3 Ap-p (40 Hz to 1 MHz) HSA42012 2.12 Arms,6 Ap-p (40 Hz to 1 MHz) HSA42014 4.24 Arms,12 Ap-p (40 Hz to 1 MHz)  Maximum output current (DC) HSA42011 ±1 A HSA42012 ±2 A HSA42012 ±4A  HSA42011 / HSA42012 / HSA42014...
  • Page 54: Figure 3-7. How To Remove And Attach The Bnc Cover

    (a) Put in the BNC cover. (2) Rotate the BNC cover counterclockwise. (b) Rotate the BNC cover clockwise. (3) Pull out the BNC cover. (c) Tighten the screw. Figure 3-7. How to Remove and Attach the BNC Cover 3-10 HSA42011 / HSA42012 / HSA42014...
  • Page 55: Monitor Output Connector

    The output on state is set when a short circuit is made Output on/off (C) between pins 9 and 5. Output on/off (E) (15 V or less and 10 mA or less between the pins) 3-11 HSA42011 / HSA42012 / HSA42014...
  • Page 56: Figure 3-8. External Control I/O

    Figure 3-8. External Control I/O BA4825 +5 V Output on when external contact is on ダイオードの電圧降下 約1 V 150  外部出力オン/オフ (外部接点オン時,出力オン) 100  Figure 3-9. Example for I/O Control by Using External Switch 3-12 HSA42011 / HSA42012 / HSA42014...
  • Page 57: I/O Connection

      信号発生器の出力インピーダンス   Times   BA4825の入力インピーダンス設定 Input impedance setting of this product * With WF series, an output voltage for an arbitrary load impedance (1 to 10k ) can be set. 3-13 HSA42011 / HSA42012 / HSA42014...
  • Page 58: Signal Cords

    1 second elapses after switching the input connector or input impedance, the input connector or the input impedance is not switched. To switch the input connector or input impedance in succession, insert a pause of at least 1 second. 3-14 HSA42011 / HSA42012 / HSA42014...
  • Page 59: Output Voltage Adjustment

    Note: This function is for making fine adjustment to set the offset voltage included in the output signal to zero. Do not use this function, but instead follow “3.5.4 DC Bias Addition” when adding DC voltage to the output signal. OFFSET Figure 3-12. Center Position of Offset Fine Adjustment 3-15 HSA42011 / HSA42012 / HSA42014...
  • Page 60: Dc Bias Addition

    Note that the output polarity is not switched, even if the output polarity switch (INVT) is pressed again before 1 second elapses after switching the output polarity. Insert a pause of at least 1 second to switch the output polarity in succession. 3-16 HSA42011 / HSA42012 / HSA42014...
  • Page 61: Output Voltage Monitoring

    With 11 LEDs, the level of 0% to 100% is displayed with the output voltage full scale of 75 V and the output current full scale of 1.06 A for HSA42011, 2.12 A for HSA42012 and 4.24 A for HSA42014 as 100%.
  • Page 62: Output On/Off Control

    Initial values for start-up time can be set by using the DIP switch on the rear panel. "Table 3-2 List of DIP Switch Settings" indicates the function of each switch. Refer to each section indicated in the column "Section to be referenced" for setting details. 3-18 HSA42011 / HSA42012 / HSA42014...
  • Page 63: Table 3-2. List Of Dip Switch Settings

    Impedance Selection B input off Input impedance setting 3.5.1 Input Selection and Input 50  DOWN Impedance Selection. 10 k DC bias on/off DOWN DC bias on 3.5.4 DC Bias Addition DC bias off 3-19 HSA42011 / HSA42012 / HSA42014...
  • Page 65: Advanced Operations

    4. ADVANCED OPERATIONS Maximum Output Current and Operation Range ········· 4-2 Increasing of Output ············································· 4-5 HSA42011 / HSA42012 / HSA42014...
  • Page 66: Maximum Output Current And Operation Range

    A maximum output current is determined by this protection circuit. This limitation value varies, depending on the output time and output voltage. The relationships are shown in "Figure 4-1 HSA42011 Operation Range ", "Figure 4-2 HSA42012 Operation Range" and "Figure 4-3 HSA42014 Operation Range".
  • Page 67: Figure 4-2. Hsa42012 Operation Range

    4.1 Maximum Output Current and Operation Range Output Voltage [V] 出力電圧 [V] -4.0 -3.0 -2.0 -1.0 出力電流 [A] Output Current [A] -100 Figure 4-2. HSA42012 Operation Range Output Voltage [V] 出力電圧 [V] -8.0 -6.0 -4.0 -2.0 出力電流 [A] Output Current [A] -100 Figure 4-3.
  • Page 68: Figure 4-4. Current Waveform Asymmetric With Regard To Polarity

    The average values (+Iave, Iave) and peak values (+Ipk, Ipk) are limited by the DC operation limitation range and AC peak operation limitation range, respectively. +Ipk +Iave −Ipk −Iave Figure 4-4. Current Waveform Asymmetric with Regard to Polarity HSA42011 / HSA42012 / HSA42014...
  • Page 69: Increasing Of Output Voltage By Balanced Output

    This product This product 本製品 本製品 1CH 30 MHz Signal generato 信号発生器 同相 逆相 Reversed- In-phase phase 負荷 Load Be sure to connect the GND terminals of the two output. Figure 4-5. Connection of Two Units HSA42011 / HSA42012 / HSA42014...
  • Page 71: Troubleshooting

    5. TROUBLESHOOTING Error Messages ··················································· 5-2 5.1.1 Errors at Power-on ········································· 5-2 5.1.2 Errors Related to the Protection Function ············ 5-3 When Fault Symptoms Are Observed ······················· 5-5 HSA42011 / HSA42012 / HSA42014...
  • Page 72: Error Messages

    Errors and their causes are described below, together with required actions. 5.1.1 Errors at Power-on This product performs self-diagnosis when the power is turned on. If an abnormality is found, contact NF Corporation or its representative. Table 5-1. Diagnosis Performed at Power-on Diagnosis item...
  • Page 73: Errors Related To The Protection Function

    5.1 Error Messages 5.1.2 Errors Related to the Protection Function The errors related to the protection function are shown below. Contact NF Corporation or its representative if an abnormality is found. Table 5-2. Errors Related to the Protection Function (1/2) State...
  • Page 74 Voltage of amplifier DC power LEDs are blinking. supply supply (internal power supply) is Turn off the power, and then turn it on again. abnormality lower than specification. If the LEDs keep blinking, this product may have failed. HSA42011 / HSA42012 / HSA42014...
  • Page 75: When Fault Symptoms Are Observed

    5.2 When Fault Symptoms Are Observed 5.2 When Fault Symptoms Are Observed When a fault symptom shown below is observed, perform the corresponding action required. Contact NF Corporation or its representative if the symptom cannot be corrected. Table 5-4. When Fault Symptoms Are Observed (1/2)
  • Page 76: Table 5-5. When Fault Symptoms Are Observed (2/2)

    Lower the input signal (output voltage) or use a rises and falls, the current that is the input signal is a signal generator, such as the NF WF1947, that charged to the stray capacitance in square wave, even if controls the rise and fall of waveforms to decrease this product reaches the peak with no load.
  • Page 77: Maintenance

    Measurement of Maximum Output Voltage (DC) ··· 6-8 6.4.3 Measurement of Frequency Characteristics ········· 6-9 6.4.4 Measurement of Gain Accuracy ························ 6-11 6.4.5 Measurement of Sine Wwave Distortion Ratio ···· 6-12 6.4.6 Measurement of Bias-Added Voltage ················ 6-14 HSA42011 / HSA42012 / HSA42014...
  • Page 78: Introduction

     Performance test required, for example, for preventive maintenance, acceptance testing, and performance confirmation after repair See section "2.4 Simplified Operation Check" for simplified operation checking. Contact NF Corporation for calibration or repair if an operation check or performance test cannot be made successfully. HSA42011 / HSA42012 / HSA42014...
  • Page 79: Daily Maintenance

    The air filter will not function normally if the filter is soiled by very fine dust (fine powder) or clogged. Do not install this product in a place where this product is exposed to much dirt and dust (including fine powder) or the humidity is high and condensation can easily occur. HSA42011 / HSA42012 / HSA42014...
  • Page 80: Storage, Repacking, And Transportation

     When repacking this product, insert cushioning materials to protect the six faces of the main unit.  When asking a carrier to transport this product, notify the carrier that this product is a precision device.  Be sure to include the instruction manual at transportation. HSA42011 / HSA42012 / HSA42014...
  • Page 81: Performance Testing

    For output wiring, use a coaxial cable of 50  not exceeding a total length of 50 cm. ● Be sure to use a 10:1 probe when connecting an oscilloscope. ● Be sure to use a 1/100 voltage divider resistance when connecting a spectrum analyzer. ● HSA42011 / HSA42012 / HSA42014...
  • Page 82  Check that the ambient temperature is within the range 5C to 35C, and the ambient humidity is within the range 5% to 85% RH.  Check that there is no condensation.  Check that 30 minutes or more has elapsed after the power has been turned on. HSA42011 / HSA42012 / HSA42014...
  • Page 83: Measurement Of Maximum Output Voltage (Ac)

     Test procedure <1> Set the waveform of the signal generator to sine wave, and set the frequencies shown in "Table 6-1 Judgment of HSA42011 / HSA42012 / HSA42014 Performance". <2> Set the output on/off switch of this product to ON.
  • Page 84: Measurement Of Maximum Output Voltage (Dc)

    <2> Set bias addition to ON, and increase the dial gradually from 5.00. <3> Record the output voltage value immediately before the overload LED (OVLD) lights. This product 本製品 DC voltmeter 直流電圧計 Terminating 終端抵抗 resistor Figure 6-3. Measurement of Maximum Output Voltage (DC) HSA42011 / HSA42012 / HSA42014...
  • Page 85: Measurement Of Frequency Characteristics

    <2> Perform UP (or DOWN) sweep operation for measurement at 100 Hz to 1 MHz. <3> Move the cursor after measurement to read the gains at 400 Hz, 100 kHz, 500 kHz, and 1 MHz. HSA42011 / HSA42012 / HSA42014...
  • Page 86: Figure 6-4. Measurement Of Frequency Characteristics

    6.4 Performance Testing This product 本製品 F R A Terminating 終端抵抗 resistor Figure 6-4. Measurement of Frequency Characteristics 6-10 HSA42011 / HSA42012 / HSA42014...
  • Page 87: Measurement Of Gain Accuracy

     Test procedure <1> Set the gain of this product and the output voltage of the FRA as shown in "Table 6-1 Judgment of HSA42011 / HSA42012 / HSA42014 Performance". <2> Turn on the outputs of this product and FRA.
  • Page 88: Measurement Of Sine Wwave Distortion Ratio

    <2> Measure the 2nd to 10th harmonic spectrum at a frequency of 100 kHz, and convert it to the distortion ratio. V 10 10 +10 10 +・・・+10 Distortion ratio %= ×100 : Fundamental spectrum [dBm] to V : 2nd to 10th harmonic spectrum [dBm] 6-12 HSA42011 / HSA42012 / HSA42014...
  • Page 89: Figure 6-5. Measurement Of Sine Wave Distortion Ratio

    1CH 30 MHz This product side Spectrum analyzer side Signal generato 信号発生器 2.5k 50 1/100 voltage 1/100分圧抵抗 divider resistance Terminating 終端抵抗 resistor Spectrum analyzer スペク トラムアナライザ Figure 6-5. Measurement of Sine Wave Distortion Ratio 6-13 HSA42011 / HSA42012 / HSA42014...
  • Page 90: Measurement Of Bias-Added Voltage

    <3> Measure the output voltages at scale marks of 0.71 and 9.29. <4> After a measurement, set bias addition to OFF and set the dial to 5.00 for safety. This product 本製品 DC voltmeter 直流電圧計 Terminating 終端抵抗 resistor Figure 6-6. Measurement of Bias-Added Voltage 6-14 HSA42011 / HSA42012 / HSA42014...
  • Page 91: Table 6-1. Judgment Of Hsa42011 / Hsa42012 / Hsa42014 Performance

    6.4 Performance Testing The performance of this product is normal if the following criteria are satisfied: Table 6-1. Judgment of HSA42011 / HSA42012 / HSA42014 Performance Measured Set frequency Criterion Judgment value 6.4.1 20 Hz 45 Vrms or more _ _ . _ _...
  • Page 93: Specifications

    7.16 External Dimensions ............. 7-11 Values that indicate accuracy are guaranteed values, but values that do not indicate accuracy are reference or typical (typ.) values. The reference values are supplemental data and are not guaranteed. HSA42011 / HSA42012 / HSA42014...
  • Page 94: Input

    10 V Maximum input voltage 11 V Non-destructive maximum input voltage Input terminal BNC connector Number of terminals: 2 Input A: Front panel, Input B: Rear panel The Lo side is connected to the chassis. HSA42011 / HSA42012 / HSA42014...
  • Page 95: Output

    Output terminal BNC connector Number of terminals: 2 (front panel and rear panel) The Lo side is connected to the chassis. The front panel and rear panel terminals are connected in parallel. HSA42011 / HSA42012 / HSA42014...
  • Page 96: Monitor Output

    If the state lasts for 60 seconds, a transition is made to disable mode. FAN abnormality When an abnormality is detected, output turns off and a transition is made to disable mode. * Disable mode: All the operations except power-off are disabled. HSA42011 / HSA42012 / HSA42014...
  • Page 97: External Control I/O

    7.7 Output On/Off Control Item All models Output on/off Controllable using the switch on the front panel or external control input (When external control is used, the switch on the front panel can be set to OFF only.) HSA42011 / HSA42012 / HSA42014...
  • Page 98: Setting At Power-On

    *3:Electromagnetic emissions from this product may interfere with reception of radio and television broadcasts. Unless the user takes special measures to reduce electromagnetic emissions, using this product in a residential area must be avoided. HSA42011 / HSA42012 / HSA42014...
  • Page 99: Operating Environment

    The absolute humidity must be within the range 1 to 29 g/m with no condensation. Figure 7-1 shows the ambient temperature and humidity ranges. Storage condition Performance guarantee Operation guarantee 10 50 C Figure 7-1. Ambient Temperature / Humidity Ranges HSA42011 / HSA42012 / HSA42014...
  • Page 100: External Dimensions And Weight

    EIA or JIS standard and after PA-001-3574 (JIS) compliant rack. purchase Replacement Air Filter A replacement air filter. The quantity required On order PA-001-3575 per product is 1. and after purchase HSA42011 / HSA42012 / HSA42014...
  • Page 101: Output Voltage / Current Range

    40 Hz or higher that can be output. All are typical values. Output Voltage [V] 出力電圧 [V] -2.0 -1.5 -1.0 -0.5 Output Current [A] 出力電流 [A] -100 Figure 7-2. HSA42011 Output Voltage / Current Range HSA42011 / HSA42012 / HSA42014...
  • Page 102: Figure 7-3. Hsa42012 Output Voltage / Current Range

    7.15 Output Voltage / Current Range Output Voltage [V] 出力電圧 [V] -4.0 -3.0 -2.0 -1.0 出力電流 [A] Output Current [A] -100 Figure 7-3. HSA42012 Output Voltage / Current Range Output Voltage [V] 出力電圧 [V] -8.0 -6.0 -4.0 -2.0 出力電流 [A] Output Current [A] -100 Figure 7-4.
  • Page 103: External Dimensions

    7.16 External Dimensions 7.16 External Dimensions Figure 7-5. HSA42011 External Dimensions 7-11 HSA42011 / HSA42012 / HSA42014...
  • Page 104: Figure 7-6. Hsa42012 External Dimensions

    7.16 External Dimensions Figure 7-6. HSA42012 External Dimensions 7-12 HSA42011 / HSA42012 / HSA42014...
  • Page 105: Figure 7-7. Hsa42014 External Dimensions

    7.16 External Dimensions Figure 7-7. HSA42014 External Dimensions 7-13 HSA42011 / HSA42012 / HSA42014...
  • Page 107 For repair service under warranty, the product must be returned to either NF or an agent designated by NF. The Purchaser shall prepay all shipping cost, duties and taxes for the product to NF from another country, and NF shall pay shipping charges to return the product to the purchaser.
  • Page 109  We assume no responsibility for influences resulting from the operations in this manual. Copyright 2021, NF Corporation HSA42011 / HSA42012 / HSA42014 Instruction Manual NF Corporation 6-3-20, Tsunashima Higashi, Kohoku-ku, Yokohama 223-8508 JAPAN...
  • Page 112 NF Corporation 6-3-20, Tsunashima Higashi, Kohoku-ku, Yokohama 223-8508 JAPAN...

This manual is also suitable for:

Hsa42011Hsa42014

Table of Contents