Troubleshooting

4.1

Preliminary Steps

If you encounter problems, verify the following:
Power is applied to the Midspan
A crossover-type Ethernet cable has not been used
The Ethernet cable from the network is connected to the Data port
The Ethernet cable to the PD is connected to the Data & Power port
Cable pairs are attached to corresponding ports.
4.2

Troubleshooting Guide

This paragraph provides a symptom and resolution sequence in order to
assist in the troubleshooting of minor operating problems. If the steps
given do not solve your problem, do not hesitate to call your local dealer
for further assistance. Refer to Table 4-1.
Symptom
Midspan does not power
up
A port indicator is not lit
and the corresponding PD
does not operate.
PowerDsine
Table 4-1: Troubleshooting Steps
1.
Establish that the power cord is viable.
2.
Verify that the voltage at the power inlet is between 100 and 240 Vac.
3.
Remove and re-apply power to the device and check the indicators
during power up sequence..
1. The Midspan did not detect a PD and therefore the port is not enabled.
2. Verify that the PD is designed for Power over Ethernet operation.
3. Verify that you are using a standard Category 5/5e/6, straight-wired
cable, with four pairs.
4. If an external power splitter is in use, replace it with a viable splitter.
5. Verify that the PD is connected to the Data & Power output port.
6. Try to reconnect the same PD to a different port on the same or into
another Midspan. If it works, there is probably a faulty output port or
RJ-45 connection.
7. Verify that port shutdown command was not issued via the Web
manaegment.
15
P
o
w
P
o
w
Corrective Steps
The Power over Ethernet Pioneers
e
r
D
s
i
n
e
6
5
0
0
S
e
r
i
e
e
r
D
s
i
n
e
6
5
0
0
S
e
r
i
e
s
s

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pd-6512Pd-6524

Table of Contents