DANIEL 700 User Manual page 9

Nps 2 through 16 / class 150-600
Hide thumbs Also See for 700:
Table of Contents

Advertisement

User manual
P/N 3-9008-553
Figure 1-1: Pilot in closed position
A. Needle valve / strainer
B. Manual pilot control
C. Inlet pressure
D. Outlet pressure
Fully open - No control
In
Figure 1-2
bottom of the piston (P1) is greater than the pressure at (P3) plus spring force. The valve
will not open unless the pressure drop across the valve (P1 minus P2) is slightly greater
than the force applied by the main valve spring. In a non-control state, the main valve is
opened in a percentage directly proportional to (P1 minus P2).