Selecting The Information Menu - Bosch Worcester Greenstar CDi Compact ErP Series Installation, Commissioning And Servicing Instruction

Wall hung rsf gas fired condensing combination boiler
Table of Contents

Advertisement

FAULT FINDING AND DIAGNOSIS
Status
Fault
codes
codes
332
E5
Supply sensor exceeded 110°C
333
Start temporarily not allowed due to flow error on CH
338
F0
Too many short burner starts without confirmation of
water flow
341
D4
CH: supply and/or return temperatures rising too fast
342
D4
HW: supply temperature rising too fast
343
ED
CH: flue gas temperature rising but supply
temperature not
344
ED
HW: flue gas temperature rising but supply
temperature not
345
EF
Supply and/or return temperatures do not change
after burner start
346
EC
Flue gas temperature rising too fast
347
E3
Return temperature higher than supply temperature
(some time after burner start)
348
EE
HW: supply temperature too hot
349
EF
CH: Boil Detect, large delta T despite minimum
burner load
350
E2
Flow sensor shorted 351 'E2' Flow sensor
disconnected
353
--
Burn temporarily blocked due to no 20 minute
continuous OFF time in last 24 hours.
354
Overpressure setting erased
357
Primary Heat Exchanger air venting program active -
approx. 100 seconds
358
Three way valve kick
359
DHW outlet temperature too hot
364
FA
Gas valve EV2 leak test failed
365
Fb
Gas valve EV1 leak test failed
372
Temporarily ignoring CH requests to limit
temperatures of the appliance components
373
8C
SuperLock caused by too frequent thermostat
overheat detections during burning
374
8C
SuperLock caused by too frequent ionisation loss
during burning
375
E4
Preheat sensor on DHW inlet Short Circuit
376
E4
Preheat sensor on DHW Inlet Open Circuit
380
Inlet temperature greater than DHW Outlet Set point
800
CC
Outdoor sensor defect
808
A7
Domestic hot water sensor defect
810
Domestic hot water remains cold
828
Water pressure sensor defect
8.5.1

Selecting the information menu

The Information Menu is a "read only" menu. Information about the boiler
is displayed here, some of the values are updated in real time to give the
current status of the boiler.
All menus time-out after two minutes and the display returns to the
normal operation display, the display backlight turns off after another
30 seconds.
Double up or down arrows indicate that the menu can only be scrolled up
or down, an up and down arrow combination indicates position in the
menu where options can be scrolled either up or down.
To enter Information menu:
1. Press the
button to enter the information menu.
▶ A three figure boiler status code will be displayed along side the
information menu number. Refer to status code table on page 65 for
a description of the boiler status codes.
66
2. Use the
and
arrow buttons to scroll through the menu items.
▶ Press the
button again to exit the Information menu.
eco
°C
reset
ok
°F
e
max
1.
Info
eco
°C
reset
ok
°F
Info
e
max
i 1 203
Fig. 125 Accessing the Information menu
i1
Current status
Every operation and mode of the
boiler has a related boiler status code.
The boiler status code is displayed on
the screen as a three figure number.
Refer to table on page 65 or error
table for information on the boiler
status codes.
i2
Last error
This can be viewed during normal
operation. Displays the last diagnostic
code with boiler status code.
i3
Maximum heating
The maximum possible heat output is
output
displayed in kW. The boiler may have
the maximum output reduced via
Menu 3.1A
i6
DHW flow rate at 40 °C
The screen displays the current DHW
temp. rise  15%.
flow rate in litres per minute to one
decimal place.
i7
Supply temperature
This is the temperature set point for
setpoint
the primary flow from the main heat
exchanger. (This will be zero during
HW demand.)
i8
Ionization current
The ionization current should be equal
to or greater than 35 μA (micro Amps)
when boiler is at maximum rate.
i9
Flow temperature
This is the actual temperature from
the main heat exchanger displayed in
real time.
Table 29 Information menu listing
CDi Compact
2
1
1
3
0
bar
4
min
max
°C
°F
2
1
1
3
0
bar
4
2.
min
max
°C
°F
6720646608-75.1Wo
ErP
- 6 720 813 276 (2015/07)

Advertisement

Table of Contents