i10
Maximum temperature This is the current temperature from
the "Maximum safety sensor". This
sensor is mounted on the front of the
heat exchanger.
i11
DHW flow temperature The current DHW flow temperature.
i12
DHW temperature
This is the temperature selected via
setpoint
the Hot Water control knob on the
fascia.
i14
Return temperature
The current temperature returned to
the main heat exchanger.
i15
Outdoor temperature
Optional outdoor temperature sensor
needs to be connected for this menu
to be activated.
i16
Pump modulation
The current pump modulation is
displayed as a percentage.
i17
Burner modulation
The current burner modulation is
displayed as a percentage.
i18
Fan speed
The current fan speed is displayed in
Hertz. The value is up-dated in real
time.
i19
Time inputs
This indicates the status of the
optional fascia mounted controls:
0 = CH off, DHW off
1 = CH off, DHW on
2 = CH on, DHW off
3 = CH on, DHW on
i20
Software version
Firmware version of the main control
board.
i21
Software version
Firmware version of the fascia control
display board
i22
Heat Control Module
The last three digits of the HCM are
(HCM) number.
displayed:
584 = 28kW Combi N.G.
585 = 28kW Combi L.P.G.
582 = 32kW Combi N.G.
583 = 32kW Combi L.P.G.
580 = 36kW Combi N.G.
581 = 36kW Combi L.P.G.
i23
Heat Control Module
For example "4"
(HCM) version number.
Table 29 Information menu listing
CDi Compact
ErP
- 6 720 813 276 (2015/07)
8.5.2

Selecting service menus

1. Press and hold
and
buttons together for one second, the
ok
display will show Menu 1.
Double up or down arrows indicate that the menu can only be scrolled up
or down, an up and down arrow combination indicates position in the
menu where options can be scrolled either up or down.
2. Scroll up and down through the menus with the
on the right hand side of display.
eco
°C
reset
ok
°F
Eco
e
e
min
max
1.
eco
°C
reset
ok
°F
Menu 1
e
e
min
max
Test
Menu 3
Menu 2
Fig. 126 Service menu selection
8.5.3

Menu 1 - System parameters

Not applicable for Greenstar CDi Compact
Initially Menu 1 will be displayed, but will contain no options.
8.5.4

Menu 2 - Boiler parameters

1. Select Menu 2 via the
and
2. Press and hold the
button for one second to enter Menu 2.
ok
This menu lists the boiler parameters, which can be adjusted in this
menu.
To modify setting, select the desired menu option (refer to table 30) and
press the
button, the option will flash.
ok
Adjust the parameter using the
the
button to confirm.
ok
A
will display for three seconds to confirm the
update of the new value.
If the setting is confirmed please record the saved value in the empty box
next to the relevant setting in Table 30.
The same process is used for adjusting all Menus 1, 2, 3 and Test.
FAULT FINDING AND DIAGNOSIS
and
buttons
1
1
0
1.
min
max
1
1
0
bar
2.
min
max
°C
°F
°C
°F
°C
°F
°C
°F
Menu 1
ErP
scroll buttons.
and
arrow buttons and press
2
3
bar
4
2
3
4
67

Advertisement

Table of Contents
loading

Table of Contents