4.4

Heat key

The key is used to set the maximum flow temperature. The maximum flow
temperature can be set between 30 °C and 80 °C
temperature is shown on the display.
With underfloor heating systems observe the maximum permissible flow
temperature.
▶ Press the (button.
The set maximum flow temperature is displayed.
▶ Press the  or  keys to set the desired maximum flow temperature.
Supply temperature
Approx. 50 °C
Approx. 75 °C
Approx. 80 °C
Table 3 Maximum flow temperature
▶ Press the OK key to save the setting.
The symbol
appears for a short time.
4.5

DHW key

Set DHW temperature
WARNING
Hot water can cause severe scalding!
▶ Bear in mind the risk of scalding when changing the maximum DHW
temperature.
▶ Press the * key.
The set DHW temperature appears.
▶ To set the desired DHW temperature, press the  or  keys.
▶ Press the OK key to save the setting.
The symbol
appears for a short time.
Measures for hard water
To protect against increased limescale and resulting service work:
If the water is calcareous with a hard hardness range (≥ 15°dH / 27°fH/
2.7 mmol/l)
▶ Set the DHW temperature to 60 °C.
4.6

Operating the menu

Opening and closing the menu
▶ To open the menu, press the
▶ To exit the menu, press the
-or-
▶ Press the d key.
Changing the setting values
▶ To highlight a menu item, press the  key or the  key.
▶ Select the menu item with the ok key.
▶ To change the value, press the  or  key.
▶ Press the ok key.
The new value is saved.
Exiting the menu without saving values
▶ Press the d key.
1) The maximum value can be changed by the service technician.
Condens 7000 WP – 6721841196 (2022/01)
1)
The current flow
Application example
Underfloor heating system
Radiator heating system
Convector heating system
key.
key again.
4.7

Settings in the menu

The factory settings are depicted as highlighted in the following table.
Meu item
Function definition
Heating mode
• On
• Off: heating mode is switched off (summer mode). The
] symbol is shown on the display.
DHW operation
• Preheat: in comfort mode, the DHW cylinder is
reheated when the temperature differential is 5 K (5
°C) or more.
• Eco: in ECO mode, the DHW cylinder is reheated when
the temperature differential is 10 K (10 °C) or more.
• OffHot water production is switched off. The
symbol is shown on the display.
Information
The current system values and the active operating
conditions can be called up in the Information menu.
Changes are not possible.
• System pressure
• Hot water Temp. (DHW temperature)
• Weather comp. (weather-compensated control)
• Key (accessory for Internet connection)
1)
Energy consump.
Gas consumption
• Last 24h
• Last 30 days
Elec. consump.
• CH last 24 h
• CH last 30 d.
2)
Settings
• Time
1)
• Date
• DST
• Parental lock
– On
– Off
• Display
– Switch off afterSet the time after which the display
is switched off.
– Brightness
• Key illum. (key illumination)
• LanguageLanguage: Change the language of the menu
and the menu items.
Cleaning funct.
No operation is possible for 15 s. The display shows a
countdown.
Emergency mode
On and set the desired heating flow temperature.
• On
• Off
1)  § 2.4 "Display of energy data", p. 4.
2) With heating controller
Table 4
5

Shutdown

5.1

Standard decommissioning

▶ Put on/off switch to position "0".
▶ Close the gas valve below the wall hung gas condensing boiler
( Fig. 3.2, page 5).
Shutdown
7