  • Page 1 ® INSTRUCTION MANUAL 3 Series Wrist Blood Pressure Monitor Model BP6100...
  • Page 2: Table Of Contents

    Table of Contents Introduction ....................3 Important Safety Information ................5 1. Know Your Monitor ................9 2. Preparation ..................14 3. Using Your Monitor ................21 4. Using Memory Function ...............23 5. Other Settings ..................25 6. Error Messages and Troubleshooting..........26 7. Maintenance ..................28 8. Specifications..................29 9.
  • Page 3: Introduction

    Safety Instructions This instruction manual provides you with important information about the OMRON BP6100 Wrist Blood Pressure Monitor. To ensure the safe and proper use of this monitor, READ and UNDERSTAND all of the safety and operating instructions. If you do not understand these instructions or have any questions, contact 1- 800-634-4350 before attempting to use this monitor.
  • Page 4 Contraindications • This monitor is contraindicated for use in ambulatory environments. • This monitor is contraindicated for use on aircraft.
  • Page 5: Important Safety Information

    Important Safety Information Please read the Important Safety Information in this instruction manual before using this monitor. Please follow this instruction manual thoroughly for your safety. Please keep for future reference. For specific information about your own blood pressure, CONSULT WITH YOUR PHYSICIAN. Indicates a potentially hazardous situation which, if not Warning avoided, could result in death or serious injury.
  • Page 6 Indicates a potentially hazardous situation which, if not Caution avoided, may result in minor or moderate injury to the user or patient, or cause damage to the equipment or other property. • Stop using this monitor and consult with your physician if you experience skin irritation or discomfort.
  • Page 7 • Ensure that this monitor has acclimated to room temperature before taking a measurement. Taking a measurement after an extreme temperature change could lead to an inaccurate reading. OMRON recommends waiting for approximately 2 hours for the monitor to warm up or cool down when...
  • Page 8 Battery Handling and Usage • DO NOT insert batteries with their polarities incorrectly aligned. • ONLY use 2 “AAA” alkaline batteries with this monitor. DO NOT use other types of batteries. DO NOT use new and used batteries together. DO NOT use different brands of batteries together.
  • Page 9: Know Your Monitor

    1. Know Your Monitor Contents Monitor, 2 “AAA” alkaline batteries, storage case, instruction manual, quick start guide Monitor a. Wrist cuff (Wrist circumference 5.3" to 8.5" (13.5 cm to 21.5 cm)) b. Display c. Battery compartment d. [Memory] button e. [Date/Time setting] button f.
  • Page 10 Display and Symbols Date and time display Memory symbol Appears when viewing readings stored in the memory. Systolic blood pressure reading Diastolic blood pressure reading Pulse display / Memory number Pulse rate appears after the measurement. When pressing the button, the memory number appears for approximately one second before the pulse rate appears on the display.
  • Page 11 Deflation symbol Appears during cuff deflation. Heartbeat symbol Flashes while taking a measurement. Average value symbol Appears when viewing the average readings of the latest 2 or 3 readings taken within 10 minutes span. High symbol Appears if your systolic blood pressure is 130 mmHg or above and/or the diastolic blood pressure is 80 mmHg or above.
  • Page 12 Movement error symbol Appears along with readings when your body is moving during a measurement. If it appears, remove the wrist cuff, and wait for 2 to 3 minutes. Then, remain still and take another measurement. Cuff wrap guide symbol Appears if the wrist cuff is wrapped around the wrist too loosely while taking a measurement.
  • Page 13 Classification of BP (Blood Pressure) ACC/AHA 2017 Hypertension guidelines define categories of BP in adults as below. Categories of BP in Adults* BP Category Systolic BP Diastolic BP Normal < 120 mmHg < 80 mmHg Elevated 120 - 129 mmHg and <...
  • Page 14: Preparation

    2. Preparation Installing Batteries Push down the hook of the battery cover and pull downward. Insert 2 “AAA” alkaline batteries as indicated in the battery compartment.
  • Page 15 Close the battery cover. Note • When the “ ” symbol flashes on the display, it is recommended you replace batteries. • To replace batteries, turn your monitor off and remove all batteries. Then replace with 2 new alkaline batteries at the same time. •...
  • Page 16 Setting the Date and Time Note • Set your monitor to the correct date and time before taking a measurement for the first time. • As soon as batteries are correctly installed, the year flashes on the display of your monitor.
  • Page 17 Blood Pressure Measurement Tips To help ensure an accurate reading, follow these directions: • Stress raises blood pressure. Avoid taking measurements during stressful times. • Measurements should be taken in a quiet place. • It is important to take measurements at same times each day. Taking measurements in the morning and in the evening is recommended.
  • Page 18 • The blood pressure can differ between the right wrist and the left wrist, and the measured blood pressure values can be different. OMRON recommends to always use the same wrist for measurement. If the values between both wrists differ substantially, please check with your physician as to which wrist to use for your measurements.
  • Page 19 Position the wrist cuff leaving a clearance of 0.5 inch (1 to 2 cm) between the cuff and the bottom of your palm. 0.5 inch (1 to 2cm) Wrap the wrist cuff firmly around your wrist. Do not apply over clothing. Check to make sure that there is no gap between your wrist and the cuff.
  • Page 20 Sitting Correctly To take a measurement, you need to be relaxed and comfortably seated in a room with a comfortable temperature. Place your elbow on the table to support your arm. • Sit in a chair with your legs uncrossed and your feet flat on the floor.
  • Page 21: Using Your Monitor

    3. Using Your Monitor Taking a Measurement Note • To stop the measurement, press the [START/STOP] button once to deflate the wrist cuff. Caution • DO NOT use this monitor with other medical electrical (ME) equipment simultaneously. This may result in incorrect operation of the monitor and/or cause an inaccurate reading.
  • Page 22 Remain still and do not move or talk until the entire measurement process is completed. As the cuff inflates, your monitor automatically determines your ideal inflation level. This monitor detects your blood pressure and pulse rate during inflation. The “ ”...
  • Page 23: Using Memory Function

    4. Using Memory Function Your monitor automatically stores up to 60 readings. Note • This monitor can be used by multiple users. When you use memory function with other users, track (or manage) your own readings appropriately. Viewing the Readings Stored in Memory Press the button.
  • Page 24 Viewing the Average Reading Your monitor can calculate an average reading based on the latest 2 or 3 readings taken within 10 minutes span. When your monitor is off, press and hold the button for more than 2 seconds. Note •...
  • Page 25: Other Settings

    5. Other Settings Deleting All Readings Stored in Memory Press the button, then the “ ” symbol appears. While holding the button down, press and hold the [START/STOP] button for more than 2 seconds. Note • All readings will be deleted. You cannot partially delete the readings stored in the memory.
  • Page 26: Error Messages And Troubleshooting

    6. Error Messages and Troubleshooting In case of any of the below problems occur during measurement, first check that no other electrical device is within 12 inches (30 cm). If the problem persists, please refer to the table below. Display/Problem Possible Cause Solution Apply the wrist cuff correctly,...
  • Page 27 Display/Problem Possible Cause Solution Press the [START/STOP] The monitor is button again. If “Er” still malfunctioned. appears, contact customer appears service. Refer to chapter 10. Replacing all batteries with 2 new alkaline batteries is Batteries are low. recommended. Refer to flashes section 2.1.
  • Page 28: Maintenance

    7. Maintenance Maintenance To protect your monitor from damage, please follow the directions below: • Changes or modifications not approved by the manufacturer will void the user warranty. Caution • DO NOT disassemble or attempt to repair this monitor or other components. This may cause an inaccurate reading.
  • Page 29: Specifications

    8. Specifications Model BP6100 HEM-6180-Z Display LCD digital display Cuff pressure range 0 to 299 mmHg Blood pressure measurement SYS: 60 to 260 mmHg range DIA: 40 to 215 mmHg Pulse measurement range 40 to 180 beats / min. Pressure: ±3 mmHg Accuracy Pulse: ±5% of display reading...
  • Page 30 Measurable wrist 5.3" to 8.5" (13.5 to 21.5 cm) circumference Memory Stores up to 60 readings Monitor, storage case, 2 “AAA” alkaline batteries, Contents instruction manual, quick start guide Protection against electric Internally powered ME equipment shock Applied part Type BF (wrist cuff) Maximum temperature of the Lower than +118.4°F (+48°C) applied part...
  • Page 31: Fcc Statement

    9. FCC Statement FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 32: Limited Warranty

    10. Limited Warranty Your BP6100 Wrist Blood Pressure Monitor, excluding batteries, is warranted to be free from defects in materials and workmanship appearing within 2 years from the date of purchase, when used in accordance with the instructions provided with the monitor.
  • Page 33 This warranty provides you with specific legal rights, and you may have other rights that vary by jurisdiction. Because of special local requirements, some of the above limitations and exclusions may not apply to you. FOR CUSTOMER SERVICE Visit our web site at: OmronHealthcare.com Call toll free: 1-800-634-4350...
  • Page 34: Guidance And Manufacturer's Declaration

    Documents in the Scope of IEC60601-1-2:2014 Important information regarding Electro Magnetic Compatibility (EMC) BP6100 manufactured by OMRON HEALTHCARE Co., Ltd. conforms to IEC60601-1-2:2014 Electro Magnetic Compatibility (EMC) standard. Further documentation in accordance with this EMC standard is available at OmronHealthcare.com/...
  • Page 35 OMRON HEALTHCARE Co., Ltd 53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPAN Distributed by OMRON HEALTHCARE, INC. 1925 West Field Court Lake Forest, IL 60045 U.S.A. OmronHealthcare.com © 2019 OMRON HEALTHCARE, INC. Made in Vietnam 2829248-6B...

This manual is also suitable for:

3 series

Table of Contents