Installation; Burner Raising; Boiler Plate; Blast Tube Length - Riello C9337401 Installation, Use And Maintenance Instructions

Dual fuel light oil / gas burner
Table of Contents

Advertisement

4

Installation

4.1

Burner raising

In order to lift the burner, proceed as follows:
 screw the two extension bars 1) on the pins 2) (Fig. 10);
 place the two plates 3) fix them on the relevant ring nuts 4);
The four burner lifting points are indicated in Fig. 10.
3
4
1
2
4.2

Boiler plate

Drill the combustion chamber mounting plate as shown in (Fig. 11).
The position of the threaded holes can be marked using the gasket
supplied with the burner.
A
inch
1
9
/
"
16
4.3

Blast tube length

The length of the blast tube must be selected according to the indi-
cations provided by the manufacturer of the boiler, it must be great-
er than the thickness of the boiler door complete with its insulation.
The range of lengths available, L (inch), is as follows:
Model
L
RLS 160/E
11
14
/
"
16
20026897
D10111
B
C
25
1
5
12
/
" - 14
/
"
/
W
32
2
8
Installation
The manufacturer declines any and every respon-
sibility for any possible lifting movements, different
from those indicated in this manual.
WARNING
For boilers with front flue passes 13) or flame inversion chambers,
insulation material 11) must be inserted between the refractory 12)
and the blast tube 10).
This protective insulation must not compromise the extraction of
the blast tube.
For boilers having a water-cooled front, the insulation 11)-12)
(Fig. 12) is not required unless it is required by the boiler manufac-
turer.
16
GB
D455
Fig. 10
Fig. 11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rls 160/e

Table of Contents