Download Print this page
Cooper Lighting INVUE Vision Flood Brochure & Specs

Cooper Lighting INVUE Vision Flood Brochure & Specs

Vision flood architectural flood luminaire
Hide thumbs Also See for INVUE Vision Flood:

Advertisement

Quick Links

TM

Advertisement

loading

Summary of Contents for Cooper Lighting INVUE Vision Flood

  • Page 2 V I S I O N F L O O D A R C H I T E C T U R A L F L O O D L U M I N A I R E - Facade - Sign - Landscape –...
  • Page 4 F L O O D L I G H T I N G F U N D A M E N T A L S - Inverse Square Cosine Law Footcandle levels are ultimately dependent upon the projected distance, aiming angle, and luminous intensity of a lamp/reflector combination. A cursory understanding of the equation which relates these variables provides insights to proper design technique and distribution selection.
  • Page 5 F L O O D L I G H T I N G T E R M I N O L O G Y Ever wonder how NEMA (H x V) Classifications are derived, or how they relate to the performance and design application of a floodlighting distribution? How about beam and field angles, and maximum candela values? - Maximum Candela is defined as the maximum candela value emitted from the luminaire in any given direction.
  • Page 6 V I S I O N F l o o d o f f e r s a h o s t o f b e a m c o n t r o l o p t i o n s t h a t l i m i t S P I L L + G L A R E C O N T R O L - Internal Louvers - External Grid Louvers...
  • Page 7 T O P V I S O R Controls excess spill and glare on top portion of distribution. Especially useful in uplighting applications to limit light travel above an intended wall surface or sign. Mounts to accessory channel in doorframe. Compatible with all distributions.
  • Page 8: D E S I G N G U I D E

    Dark Surroundings Dark Surroundings Cooper Lighting Application Engineers are available to assist in providing design layouts, aiming diagrams, and illuminance plots for your next floodlighting project. Consult your INVUE Lighting Systems Representative for more information. B E A M P A T T E R N I N F O R M A T I O N...
  • Page 9: C O L O R C A P A B I L I T I E S

    I n f u s i n g c o l o r t o a v i s u a l l a n d s c a p e e l i c i t s a t t e n t i o n , C O L O R C A P A B I L I T I E S VISION Flood can be specified with one of four (4) standard color gels: Deep Green, Bright Blue, Red or Warm Orange.
  • Page 12 W i t h s i x ( 6 ) u n i q u e l y s h a p e d o p t i c a l d i s t r i b u t i o n s , t h e V I S I O N F l o o d p r o v i d e s t a r g e t e d l i g h t i n g s o l u t i o n s f o r f a c a d e , s i g n , l a n d s c a p e , O P T I C A L C O N F I G U R A T I O N S All optical systems are fully interchangeable, featuring toolless release fasteners and wire connectors.
  • Page 13 W I D E F L O O D [ W F ] Designed for applications requiring a wide rectangular pattern of uniform illumination. Generally used with shorter setbacks to floodlight large facades, signage, and broad leaf foliage. Also effective in pole mount applications for general area illumination.
  • Page 14 V I S I O N F l o o d l u m i n a i r e s p r o v i d e u n s u r p a s s e d l e v e l s o f p r o t e c t i o n a g a i n s t e n t r y o f a i r b o r n e c o n t a m i n a n t s .
  • Page 15 L A M P O P T I O N S VISION Flood optical systems are offered with a variety of high efficiency lamp sources. M E T A L H A L I D E / P U L S E S T A R T M E T A L H A L I D E Produces a whitish-blue light, excellent color rendition up to 92 CRI, and high efficacy (lumens per watt).
  • Page 18: Product Specifications

    H O U S I N G One-piece, die-cast aluminum housing maintains a nominal .125" thickness to endure the toughest environments while maintaining precise tolerance control. D O O R Die-cast aluminum door maintains a nominal .125" thickness and features concealed hinging to the housing.
  • Page 19 D I M E N S I O N S Vision Flood Small [VFS] 10" [254 mm] 7 1/2" X=2 15/16" 14" [356 mm] [191 mm] [75 mm] F I N I S H Housing and arm finished in a 5 stage premium TGIC polyester powder coat paint, 2.5 mil nominal thickness for superior protection against fade and wear.
  • Page 20 V F S M O U N T I N G O P T I O N S + S P E C I F I C A T I O N S - Specifications + Dimensions [VFS Standard Mount] V F S S T A N D A R D M O U N T The VFS knuckle features a 3/4"...
  • Page 21 V F S | V F M M O U N T I N G O P T I O N S + S P E C I F I C A T I O N S When coupled with the available slipfitter (SF), the VFS can be mounted to the following accessories: Surface Mount Tenon (SMT), Stanchion Mount Tenon (ST), Twin Mount Arm Tenon (TMT), and Wall...
  • Page 22 O P T I O N S + A C C E S S O R I E S S P E C I F I C A T I O N S - Specifications + Dimensions E X T E R N A L G R I D L O U V E R S Designed to control lamp glare and spill light while maintaining beam efficiency.
  • Page 23: Ordering Information

    A P P L I C A T I O N S D E P A R T M E N T Let the application experts at Cooper Lighting design your next lighting layout. Aided by the latest computer simulation software and a comprehensive lighting background, our Application Engineers can design, analyze, and provide statistical layouts for any lighting application.
  • Page 24 Chomedey, Laval P.Q. Cooper Lighting All rights reserved Printed in USA w w w. c o o p e r l i g h t i n g . c o m The Cooper Lighting Family Halo Portfolio Metalux Neo-Ray...

This manual is also suitable for:

Invue vfm-k seriesInvue vfs-k series