Indoor/Outdoor Unit Installation Drawings - Daikin FTY35GXV1 Installation Manual

Hide thumbs Also See for FTY35GXV1:
Table of Contents

Advertisement

01_EN_3P211822-2C.fm Page 3 Tuesday, November 27, 2007 6:31 PM
Indoor/Outdoor Unit
Installation Drawings
A Mounting plate
Mounting plate
fixing screw
(Field supply: M4 × 25L)
Front panel
50mm or more from walls
(on both sides)
Air filter
B
Air-Purifying Filter with bacteriostatic,
virustatic function (2)
Air-Purifying Filter
with bacteriostatic,
virustatic function
Filter frame
Tab
Before screwing
C
the remote
Wireless
controller holder
remote
to the wall, make
controller
sure that control
signals are
properly received
D
by indoor unit.
Remote
controller
holder
Screws
(Field supply: M3 × 20L)
■English
How to attach the indoor unit.
Hook the claws of the bottom frame
to the mounting plate.
If the claws are difficult to hook,
remove the front grille.
How to remove the indoor unit.
Push up the marked area (at the
lower part of the front grille) to
release the claws. If it is difficult to
release, remove the front grille.
30mm or more from ceiling
M4 × 12L
Opening service lid
Service lid is opening/closing type.
Opening method
1) Remove the service lid screws.
2) Pull out the service lid diagonally
down in the direction of the arrow.
3) Pull down.
Air filter
In sites with poor drainage, use block
bases for outdoor unit. Adjust foot height
until the unit is leveled. Otherwise, water
leakage or pooling of water may occur.
Front grille
Caulk
pipe hole
gap
with putty.
Service lid
Model
Min. allowable length
Max. allowable length
Additional charge of refrigerant
Max. allowable length without
additional charge
Max. allowable height
Where there is a danger of the unit
falling, use foot bolts, or wires.
unit: mm
A Mounting
plate
Clip
Bottom frame
Mark (rear side)
Cut thermal insulation
pipe to an appropriate
length and wrap it with
tape, making sure that no
gap is left in the insulation
pipe's cut line.
Wrap the insulation pipe with
the finishing tape from bottom
to top.
25
35
3m
15m
20g/m
10m
10m
Gas pipe
O.D. 9.5mm O.D. 12.7mm
Liquid pipe
O.D. 6.4mm
*
Be sure to add the proper amount of additional refrigerant.
Failure to do so may result in reduced perfomance.
Stop valve cover
How to remove the stop
valve cover.
Remove the screw on the
stop valve cover.
Slide the lid downward
to remove it.
How to attach the stop
valve cover.
Insert the upper part of
the stop valve cover into the
outdoor unit to install.
Tighten the screws.
Allow space for piping
and electrical servicing.
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fty25gxv1

Table of Contents