Outdoor Unit Installation Guidelines - Daikin FTY35GXV1 Installation Manual

Hide thumbs Also See for FTY35GXV1:
Table of Contents

Advertisement

01_EN_3P211822-2C.fm Page 4 Tuesday, November 27, 2007 6:31 PM

Outdoor Unit Installation Guidelines

• Where a wall or other obstacle is in the path of outdoor unit's intake or exhaust airflow, follow the installation guidelines below.
Wall facing one side
More than 50
CAUTION
When operating the air conditioner in a low outdoor ambient tempera-
ture, be sure to follow the instructions described below.
1) To prevent exposure to wind, install the outdoor unit with its suction
side facing the wall.
2) Never install the outdoor unit at a site where the suction side may
be exposed directly to wind.
3) To prevent exposure to wind, it is recommended to install a baffle
plate on the air discharge side of the outdoor unit.
4) In heavy snowfall areas, select an installation site where the snow
will not affect the unit.
CAUTION
In the case of using a mount and installing the outdoor unit on the wall or
roof, attach vibration absorbers (e.g., vibration isolation rubbers and
springs) between the legs of the outdoor unit and the mount (4 portions).
4
More than 100
Side view
Walls facing two sides
More than 100
More than 50
Top view
Walls facing three sides
More than 150
More than 300
More
than 50
Top view
More
than 150
More than 50
Unit: mm
Construct a large canopy.
Construct a pedestal.
Install the unit high enough off the
ground to prevent burying in snow.
■English