Page 1
User Manual Blast Chiller/Freezer 11/2021 449SF3, 449SF5, 449SF10 Please read the manual thoroughly prior to equipment set-up, operation and maintenance. - 1 -...
Page 2
User Manual Warning DANGER – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. TO BE REPAIRED ONLY BY TRAINED SERVICE PERSONNEL. DO NOT PUNCTURE REFRIGERANT TUBING. PELIGRO - RIESGO DE INCENDIO O EXPLOSION. REFRIGERANTE INFLAMABLE UTILIZADO. PARA SER REPARADO SOLAMENTE POR PERSONAL DE SERVICIO CALIFICADO. NO PINCHAR LA TUBERÍA REFRIGERANTE.
User Manual Installation Please read this manual thoroughly prior to equipment set-up, operation and maintenance. Important!!! Please Read Before Installation • If the unit has recently been transported on its side, please let the unit stand upright for a minimum of 24 hours before plugging it in. •...
User Manual Digital Temperature Controller Control Description When power button is engaged, the unit will engage in pre-cooling mode. The temperture displays the Power Button current temperature in the cabinet, and the time will display the last set time. From the Pre-cool mode, press the set button to change the time or temperature. When temperature Set Key flashes, press ‘+’...
User Manual Other Controls Description To change between C and F Can be switched by pressing and holding the SET and ‘-’ button for 3 seconds. View the set temp and time Press and hold the SET button to view set temperature and set time. Electrical •...
Page 6
User Manual Quick Start Guide Getting Started 1. To get started, press the Power Button (1) to enter the precooling mode. Allow the unit to precool for 20 minutes before starting the cooling process. Manual Set 1. Under the precooling mode, press the Set Button (2) to switch between the temperature and time settings.
Page 7
User Manual Quick Start Guide Hard Freeze 1. The hard freeze setting is used to switch between reading and displaying the temperature of the probe and the temperature of the cabinet (probe is default). 2. The Snowflake (11) indicator light will illuminate to show that the unit is reading the temperture of the core of the product using the probe.
User Manual Troubleshooting Compressor Not Running Fuse blown or circuit breaker tripped. Replace fuse or reset circuit breaker. Power cord unplugged. Plug in power cord. Thermostat set too high. Set thermostat to lower temperature. Cabinet in defrost cycle. Wait for defrost cycle to finish. Compressor Continuously Running Compressor is continuously running.
• Models 449SF5 and 449SF10 have a condensation drain that should be cleaned and clear whenever in use. • 449SF3 does not have a drain for condensation and should be wiped out periodically to prevent damage from moisture. - 9 -...
Need help?
Do you have a question about the 449SF3 and is the answer not in the manual?