Dukane 6000 Series User Manual page 28

Linear vibration welder
Table of Contents

Advertisement

Linear Vibration Welder 6000 Series
Machine Air
The welder requires a supply of clean, dry, compressed
air at 75 to 90 psi. The connection is made using 1 /2
inch (12mm for international models) O.D. tubing at
the pneumatic lockout device. Turn the valve to the right
as shown in Figure 3-9 to open the valve and apply the
compressed air. The air is used to raise and lower the
front access door and for any optional vacuum part–
retention or pneumatic clamping and ejection features.
Clear Emergency Stop and Reset
Welder
A typical sequence consists of: Reset both Emergency
Stop Buttons (
) by turning clockwise and pulling
E-STOP
up. These are shown in Figure 3-10. Clear any alarms.
E-STOP RESET
Press the
light will go out. If the light does not go out, check the
rear service doors. They should be securely closed, and
the door interlocks should be engaged.
Figure 3-  10 E–STOP and Reset Buttons
Page 22
User's Manual
button. The flashing alarm
Figure 3-  9
Pneumatic Valve In ON Position
Dukane Manual Part No. 403-619-00
SUP
SUP
Reset Button
Reset Button
Alarm Light
Alarm Light
E-Stop Buttons
E-Stop Buttons