Audio-over-IP streaming supports an unlimited number of channels in the
playback system. These audio channels are automatically synchronized perfectly
in time by the audio-over-IP streaming technology, forming a single playback
system. The 4410A accepts AES67/ST2110 and Dante audio-over-IP streams.
The streams are set up with Dante Controller or Dante Domain Manager
software. Each 4410A supports reproduction of one or the sum of two audio input
channels. The stream audio sample rate can range from 32-96 kHz, with 16-24
bit resolution.
The 4410A contains one rear panel CAT connector for standard Ethernet IP
network connectivity. The network interface speed is 100 Mbps. The rear panel
CAT connector also allows Genelec's Smart IP Manager software to work on the
4410A. This software is available for AV installers on Genelec web site and runs
on Windows 10 computers. The software allows AV installers to configure an
almost unlimited number of rooms, zones, loudspeakers and audio channels, and
includes device discovery, a versatile room acoustic equalisation tool set, system
organisation and status monitoring.
The 4410A contains an application programming interface (API) supporting
control via third-party hardware, software or house automation. The API enables
integration to all house and home automation systems. Detailed information
about the API are provided in a separate document from Genelec.
The 4410A is designed for indoor use, in temperatures 15-35 Celsius and relative
humidity 20-90 %.
PACKING CONTENT
•
Genelec two-way active loudspeaker 4410A.
•
Keyhole-type wall mount with screws.
POSITIONING AND MOUNTING THE LOUDSPEAKER
Place the loudspeaker so that the line of the acoustic axis points towards the
main listening area. The AV install designers may indicate different aiming.
The minimum clearance for amplifier cooling and reflex port function around the
loudspeaker is 3 cm (1 3/16 in) behind, above and on both sides of the
loudspeaker. If the back side of the loudspeaker is blocked, it must be ventilated
so that the ambient temperature remains below 35° C (95° F) at any moment of
operation.