Alternative method (1):
1. Go to SAM.
2. Select NVM Editor.
3. Select ADR (address) to 1 (dec).
4. Change the VAL (value) to 170 (dec).
5. Store the value.
6. Do a hard reset to make sure new default values took
place.
Alternative method (2):
It is also possible to upload the default values to the NVM with
ComPair in case the SW is changed, the NVM is replaced with
a new (empty) one, or when the NVM content is corrupted.
After replacing an EEPROM (or with a defective/no EEPROM),
default settings should be used to enable the set to start-up and
allow the Service Default Mode and Service Alignment Mode to
be accessed.
5.7.3
Start-up/Shut-down Flowcharts
Important note for DVB sets:
When you put a DVB set into Stand-by mode with an RC,
the set will go to "Semi Stand-by" mode for 5 minutes. This,
to facilitate "Off the Air download" (OAD). If there is no
activity within these 5 minutes, the set will switch to Stand-
by mode. In "Semi Stand-by" mode, the LCD backlight and
Audio Amplifier are turned "off" but other circuits still work
as normal. The customer might think the set is in Stand-by.
However, in real Stand-by mode, only the uP and the NVM
are alive and all other circuits are switched "off".
If you press the mains switch at the local key board in a
DVB set, the set will switch to Stand-by mode.
On the next pages you will find start-up and shut-down
flowcharts, which might be helpful during fault finding.
Please note that some events are only related to PDP sets,
and therefore not applicable to this LCD chassis.
Service Modes, Error Codes, and Fault Finding
LC7.1E LB
5.
EN 19