M-system MRP10 Instruction Manual

Step-top electronic actuator

Advertisement

Quick Links

INSTRUCTION MANUAL
STEP-TOP ELECTRONIC ACTUATOR
(Rotary type; Modbus communication)
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
Step-Top Electronic Actuator unit......................................(1)
The Step-Top Electronic Actuator is not provided with a
yoke or other components required for mounting the unit to
a valve. They are to be provided by the user.
■ MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■ SAFETY PRECAUTIONS
Before use, please read all the following precautions
carefully to ensure the safety. These safety precautions,
classified into "WARNING" and "CAUTION" according to
the degree of damage that may be caused by improper use
of the product, are imperative to prevent an accident. Af-
ter reading, be sure to keep this manual always in a visible
and accessible place for the user.
WARNING Suggesting that failure to observe the pre-
cautions could result in death or serious personal injury.
CAUTION Suggesting that failure to observe the pre-
cautions could result in personal injury or damage to the
property.
WARNING
Remove power supply to the actuator before wiring to the
unit. It could cause electric shock.
Do not disassemble or modify the unit in any way.
It could cause electric shock, burn, or injury.
DO NOT step onto the actuator unit.
DO NOT rest a heavy object on or against the unit.
It could cause personal injury.
When installing the actuator unit outdoor or where it
is exposed to rain or water drops, adequate precautions
must be taken for preventing water from entering inside
through wiring conduits. It could cause electric shock.
CAUTION
DO NOT remove the cover of the actuator. It may cause
electric shock or injury.
The adjusters which are paint-sealed are for factory use
only and should be changed only by qualified M-System
personnel. Otherwise it could cause breakdown.
M-System is not liable for any malfunction or inconven-
ience caused by unauthorized changes made by the user.
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
MODEL
■ INSTRUCTION MANUAL
This manual describes necessary points of caution for han-
dling this product and specifically for installation, wiring,
hardware setting, and basic maintenance of the product.
This unit is factory-adjusted and calibrated according to the
Ordering Information Sheet.
When the user needs to change settings, please also refer to
the Section B of Operation Manual (EM-9255) for the Pro-
gramming Unit (Model: PU-2x).
POINTS OF CAUTION
■ POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC: 24V rating ±10%, approx. 1 A
■ HUNTING
• Hunting is a condition in which the output stem is os-
cillated repeatedly and persistently without settling at a
single position.
• The actuator unit must operate at an average duty cycle
of 50% (approx. 13 strokes per minute) or less.
■ GENERAL PRECAUTIONS
• Remove the power supply to the actuator before wiring
the unit.
• DO NOT install signal wires and power supply wires to-
gether in one duct because it may cause a malfunction
due to induction noises. Alternatively, use shielded cables
for the input signal wires to prevent interference from
such noises.
• If input signals are to be turned on/off with power sup-
plied to the actuator, be sure to specify the output stem
operation for when abnormally low input is detected.
• DO NOT loosen the screws fixing the potentiometer in-
side the unit.
■ INSTALLATION
• Indoor, or outdoor where the unit is NOT exposed to di-
rect sunlight.
• Operating temperature -25 to +66°C (-13 to 150.8°F)
• Operating humidity 30 to 90% RH (non-condensing)
• The unit is not designed to withstand all vibrations.
M-System does not guarantee long-term use of the unit
even with small vibrations. Please use the unit only after
evaluating in an actual installation environment. Par-
ticularly, avoid using under the condition where valve
cavitation or water hammer is likely to occur.
• Install the unit where it can be reached for maintenance
and inspection. Be sure to allow at least 20 cm (7.9 inch-
es) clearance above the unit and around the terminal box.
• Keep away from hazardous atmosphere such as explosive
or corrosive gases.
MRP10
EM-4889 P. 1 / 13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MRP10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for M-system MRP10

  • Page 1 This manual describes necessary points of caution for han- dling this product and specifically for installation, wiring, Thank you for choosing M-System. Before use, please check hardware setting, and basic maintenance of the product. contents of the package you received as outlined below.
  • Page 2 LEDs are in the terminal BOX. Remove the transparent cover to work. • The quality inside the mechanism is stabilized by not re- moving the cover. EM-4889 P. 2 / 13 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 3: Component Identification

    Indicator Stepping Motor Heater Packing Potentiometer Transparent Cover Terminal Block Packing Wiring Conduits (4-G1/2) Manual Output Stem Operation Stem Terminal Box Figure 1. Component identification: MRP10 + INPUT − U(+) + POWER OUTPUT V(−) − UP/CCW SIG. Modbus DOWN/CW SIG. Configuration (Type-C) ALARM SIG.
  • Page 4 Parameter settings for Auto-setup and communication settings for Modbus can be configured on PU-2x. In addition, operation status of the unit can be monitored on PU-2x. EM-4889 P. 4 / 13 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 5: Wiring Connection

    Tx+ / Rx+ Tx- / Rx- Terminating resistors can be turned ON/OFF on the PC configurator software (model: STCFG) or programming unit (model: PU-2x). EM-4889 P. 5 / 13 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 6: Operation

    PC CONFIGURATOR SOFTWARE (MODEL: STCFG) The PC configurator software helps the user to configure various parameters and to monitor operation status of the actuator. Download the STCFG from “Download” on the M-System’s web site https://www.m-system.co.jp Prepare the PC and the USB Type-C cable separately.
  • Page 7 DATA-ERR : Value is invalid or out of range ■ PARAMETER ITEM LIST Refer to “PARAMETER ITEMS COMMON TO MODBUS, CONFIGURATOR SOFTWARE AND PU-2x” for the parameter item list. EM-4889 P. 7 / 13 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 8: Modbus Communication

    DIP switches 1-1 and 1-2 of the unit. • Refer also to “COMBINATION OF OPERATION MODE AND SPECIFICATIONS”. EM-4889 P. 8 / 13 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 9: Device Information

    Time ratio (%) of 50 - 60% position * 0.0 to 100.0 Pos50R:x – ✓ Time ratio (%) of 60 - 70% position * 0.0 to 100.0 Pos60R:x – ✓ EM-4889 P. 9 / 13 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 10: Modbus Input

    [2: Configuration mode] · All R/W registers are readable and writable. · Registers other than the above are read only. · Operation stops. EM-4889 P. 10 / 13 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 11: Modbus Setting

    Set the operation speed on a scale of 1 to 10. The higher the number, the faster the speed. Operation speed at the shipment is 10. EM-4889 P. 11 / 13 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 12 *6 The output stem operates according to the settings of SW1-1 and 1-2 when a Modbus disconnection error is detected. *7 Includes writing to Modbus address 5 to 16, 51, 52, 101, and 111. EM-4889 P. 12 / 13 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 13: Maintenance

    Screws Check that screws and bolts are securely fastened. Re-tighten them, if loose. For repair or parts replacement, contact M-System or our representatives. ■ LUBRICATION There is no need of oiling the Mini-Top electronic actuator in normal operating conditions. ■ REGULAR TEST RUNNING If the valve is not frequently operated, run a test operation regularly (once a week, for example) to ensure that the actuator operates normally.