M-system SC100 Series User Manual

Multi-function pid controller
Hide thumbs Also See for SC100 Series:

Advertisement

Quick Links

SC100/SC200 Series
Multi-Function PID Controller
PC CONFIGURATOR SOFTWARE
Model: SCCFG
Users Manual
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Tel: +81-6-6659-8201
Fax: +81-6-6659-8510
http://www.m-system.co.jp/
E-mail: info@m-system.co.jp
1
SCCFG Users Manual EM-9192 Rev.4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SC100 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for M-system SC100 Series

  • Page 1 SC100/SC200 Series Multi-Function PID Controller PC CONFIGURATOR SOFTWARE Model: SCCFG Users Manual 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Tel: +81-6-6659-8201 Fax: +81-6-6659-8510 http://www.m-system.co.jp/ E-mail: info@m-system.co.jp SCCFG Users Manual EM-9192 Rev.4...
  • Page 2: Table Of Contents

    C ont ent s 1. INTRODUCTION ...................3 2. BEFORE GETTING STARTED .............4 GENERAL DESCRIPTIONS ....................4 SYSTEM REQUIREMENTS ....................4 3. MAIN DIALOG ..................5 4. COMMUNICATION ................6 COP-IRDA COMMUNICATION ADAPTOR .................6 SETTING ON THE CONTROLLER ..................6 COP-US COMMUNICATION ADAPTOR ................6 SETTING ON THE CONTROLLER ..................6 5.
  • Page 3: Introduction

    INTRODUCTION Thank you for choosing M-System’s SC100/200 Series Multi-Function PID Controllers. This manual describes software functions of PC Configurator Software model: SCCFG, PC environment and opera- tion methods. Please refer to the relevant hardware users manuals for the detailed information about the terms used in this manual.
  • Page 4: Before Getting Started

    BEFORE GETTING STARTED GENERAL DESCRIPTIONS Configuration setting data saved in the Controller is uploaded to a PC via infrared com- Uploading and saving setting data munication and saved in binary or CSV file format. Configuration setting data saved in the PC is downloaded to the Controller via infrared Downloading setting data communication.
  • Page 5: Main Dialog

    MAIN DIALOG Double-clicking SCCFG.exe icon starts the SCCFG to show Main Dialog as shown below. (1) “Uploaded from device” is indicated when [Upload from device] has been successfully completed. File name is indicated when [Read CFG file] has been successfully completed. (2) Device Model and LCD Ver.
  • Page 6: Communication

    COMMUNICATION COP-IRDA COMMUNICATION ADAPTOR Use M-System’s Model COP-IRDA or COP-US to communicate with the Controller via infrared rays. Before using the COP-IRDA, install its driver in your PC. Refer to the instruction manual for the COP-IRDA for more information. When the driver is installed correctly, the COP-IRDA is assigned to a COM port.
  • Page 7: Com Port Setting

    COM PORT SETTING Select COM No. assigned to the COP-IRDA or COP-US among COM1 to COM20. SCCFG Users Manual EM-9192 Rev.4...
  • Page 8: Configuration

    CONFIGURATION UPLOAD FROM DEVICE Click on [Upload from Device] button to call up the setting data saved in the Controller. READ CFG FILE Click on [Read CFG file]. The folder directory appears on the screen. Select a configuration file and click on [Open]. DOWNLOAD TO DEVICE Click on [Download to device] button to write the setting data presently on the screen.
  • Page 9: 6.3.1 Write To Device With Different Lcd Firmware Version

    6.3.1 WRITE TO DEVICE WITH DIFFERENT LCD FIRMWARE VERSION When the LCD firmware version of setting data, which is created by “READ CFG FILE” or “DOWNLOAD TO DEVICE” , is different from the LCD firmware version of destination device, the data may change to factory setting value depend- ing on configuration item.
  • Page 10: Write To Cfg File

    WRITE TO CFG FILE Click on [Write to CFG file]. The folder directory appears on the screen. Type the name and click on [Save]. EXPORT TO CSV Click on [Export to CSV]. The folder directory appears on the screen. Type the name and click on [Save]. SCCFG Users Manual EM-9192 Rev.4...
  • Page 11: Configuration Data In Csv Format

    CONFIGURATION DATA IN CSV FORMAT For LCD firmware version 1.3x, 1.4x (SC100, SC110, SC200, SC210) SC210 Configuration LCD Ver. 1.3x, 1.4x Group Item Data Back light brightness Screen saver (time) (0=OFF) MV 0/100% symbol MV1 100% symbol MV1 0% symbol MV2 100% symbol MV2 0% symbol Items under Bargraph color and Digital...
  • Page 12 Modbus-RTU Node address Transfer rate 38400 Data bit (8 bit) SC200/SC210 only Parity Modbus/TCP IP address 192.168.0.1 Subnet mask 255.255.255.0 Port No. (502 fixed) Linger time Language English DATA DATA DATA DATA User’s parameter table Setting Parameter GROUP ITEM Hi limit Lo limit decimal place engineering unit...
  • Page 13 For LCD firmware version 1.5x or later (SC100, SC110, SC200, SC210) SC210 Configuration LCD Ver. 1.5x Group Item Data Back light brightness Screen saver (time) (0=OFF) MV 0/100% symbol MV1 100% symbol MV1 0% symbol MV2 100% symbol MV2 0% symbol Loop display (MV/OP) LP1 display (MV) LP2 display (MV) Items under Bargraph color and Digital...
  • Page 14 PRG mode indicator Numerical key control Enable Enable Enable Enable Modbus-RTU Node address Transfer rate 38400 Data bit (8 bit) SC200/SC210 only Parity Modbus/TCP IP address 192.168.0.1 Subnet mask 255.255.255.0 Port No. (502 fixed) Linger time Language English Parameter GROUP ITEM Range Hi Range Lo Decimal Engineer-...
  • Page 15 For SC200D SC200D Configuration LCD Ver. 1.0x Group Item Data Back light brightness Screen saver (time) (0=OFF) MV 0/100% symbol MV1 100% symbol MV1 0% symbol MV2 100% symbol MV2 0% symbol Loop display (MV/OP) LP1 display (MV) LP2 display (MV) Items under Bargraph color and Digital Loop variables PV/SP/MV...
  • Page 16 PRG mode indicator Numerical key control Enable Enable Enable Enable Modbus-RTU Node address Transfer rate 38400 Data bit (8 bit) Parity Modbus/TCP IP address 192.168.0.1 Subnet mask 255.255.255.0 Port No. (502 fixed) Linger time Language English Parameter GROUP ITEM Range Hi Range Lo Decimal Engineer-...
  • Page 17 For SC200W, SC210W SC200W Configuration LCD Ver. 1.0x Group Item Data Back light brightness Screen saver (time) (0=OFF) MV 0/100% symbol MV1 100% symbol MV1 0% symbol MV2 100% symbol MV2 0% symbol Loop display (MV/OP) LP1 display (MV) LP2 display (MV) Items under Bargraph color and Digital Loop variables PV/SP/MV...
  • Page 18 PRG mode indicator Numerical key control Enable Enable Enable Enable Modbus-RTU Node address Transfer rate 38400 Data bit (8 bit) Parity Modbus/TCP IP address 192.168.0.1 Subnet mask 255.255.255.0 Port No. (502 fixed) Linger time Language English Parameter GROUP ITEM Range Hi Range Lo Decimal Engineer-...
  • Page 19: Configuration Item List

    CONFIGURATION ITEM LIST ITEM SUB ITEM DATA DEFAULT CONTENTS Back light brightness 1, 2, 3, 4, 5 Backlight brightness control Time before the screen turns off when not ac- cessed. Screen saver does not turn on when: Screen saver (time) 0, 1 –...
  • Page 20 ITEM SUB ITEM DATA DEFAULT CONTENTS LP1 CH1 LP1 CH2 LP1 CH3 LP1 CH4 18 colors Trend graph color Short trend graph color (CH1 thr. CH4) (color chart) * LP2 CH1 LP2 CH2 LP2 CH3 LP2 CH4 18 colors Background color of the tag field for the se- Selected loop color (color chart)* lected loop...
  • Page 21 ITEM SUB ITEM DATA DEFAULT CONTENTS As specified Language Japanese, English Display language when ordering Setting Enable, Disable Disable Enable / Disable the parameter in the User’s Pa- rameter Table view. Parameter Max. 10 characters Name Parameter identification GROUP 0 to 99 GROUP No.
  • Page 22: Short Trend Data

    SHORT TREND DATA UPLOAD AND EXPORT TO CSV Click on [Upload and export to CSV] to start communicating with the Controller via infrared. Once the communication is established, the folder directory appears on the screen. Enter file name and click on [Save] button to create a CSV file.
  • Page 23: Short Trend Data In Csv Format

    SHORT TREND DATA IN CSV FORMAT Storing interval, Storing period, Num- ber of samples and Storing status Trend channel, Data type, Tag No., Unit, Lower/Upper range, Decimal point Tag No. is indicated when Data type is set with FNx. Sampled data Values in engineering unit with decimal point at the preset position.
  • Page 24: Appx 1. Error Codes

    Appx 1. ERROR CODES ITEM ERROR TYPE CODE MESSAGE Setting data is not supported by the present version of SCCFG. Confirm the SCCFG version. Illegal data Setting data is not in the defined format. Configuration data The SCCFG failed in writing setting data to the device. Setting data is not in the defined format.