RS-232 Control
Using a RS-232 phoenix connector to RS-232 Male cable, the matrix can also be controlled using RS-232
commands. Connect the phoenix connector to the matrix and connect the RS-232 male connection to a
RS-232 Female to USB cable. The USB connector can then be connected to a PC or laptop.
Open the serial command tool which can be found at your local Lindy website under Downloads.
The ASCII command list can be found below.
Serial Port Protocol.
Baud Rate: 115200
Data Bits: 8bit
Stop Bits: 1
Check Bit: 0
X – Parameter 1
Y – Parameter 2
! – Delimiter
Command Code
Power
s power z!
r power!
s reboot!
Function
Power
on/off
the
device, z=0~1
(z=0 power off, z=1
power on)
Get
current
power
state
Reboot the device
Description
Feedback
s power 1!
Power On
System Initializing...
Initialization Finished
FW Version x.xx.xx
r power!
power on/power off
s reboot!
Reboot...
Initialisation Finished
FW Version x.xx.xx