5.4.2 DELETION PROCEDURES (WITH NON-MEMORISED
TRANSMITTER IN ONE-WAY MODE)
l
In TWO-WAY mode, follow the procedure indicated in
the paragraph "Memorising the FIRST TRANSMITTER",
sub-paragraph "TWO-WAY mode".
To do this ("Figure 15"):
1.
disconnect the power supply to the system. Wait 5 s. Power the
system again
2.
within 10 s from the power-up, press
rised transmitter. The paired LED strip will emit two or three flashes
3.
disconnect the power supply to the system. Wait 5 s. Power the
system again
4.
press PRG once on the transmitter. The paired LED strip will flash
twice
5.
press PRG once on the transmitter. The paired LED strip will flash
twice
6.
press PRG once on the transmitter. The paired LED strip will flash
three times
7.
press PRG once on the transmitter. The paired LED strip will flash
four times
8.
press the keys indicated in "Table 3" to select the desired option
among those available. At the end of the procedure, the paired LED
strip will flash three or five times to confirm the deletion.
15
1
2
OFF
ON
=
5 sec
3
4
OFF
ON
=
5 sec
6
(x 1)
PRG
x 3
DELETION
Buttons
Setting
Deletion of a SINGLE REMOTE CONTROL:
after selecting this option, press
p
x 3 s
remote control to be eliminated to complete the
procedure
Deletion of ALL SETTINGS
p
+
q
x 3 s
o
Deletion of ALL REMOTE CONTROLS
x 3 s
FULL deletion (reset to the system's factory
PRG
settings)
8 – ENGLISH
o
for 5 s on the non-memo-
(= 5s)
NEW
x 2
5
(x 1)
(x 1)
PRG
PRG
x 2
7
8
(... see
(x 1)
the table
and press
PRG
the keys)
x 4
o
on the
5.4.3 PRE-DEFINED (PRESET) OR PERSONALISED (CUSTOM)
COLOURS
The system leaves the factory (PRESET) with 8 pre-configured and avail-
able colours. Activating the "CUSTOM" function allows for memorising
personalised colours which can then be recalled.
l
After enabling the "CUSTOM" function, the personalised
intensity must be set using a memorised transmitter, as
explained in the "COMMANDS FROM THE TRANSMIT-
TER" chapter.
l
If the colours/intensities are set through the PRESET
function, refer to "Table 6". If CUSTOM colours/intensi-
ties are set, refer to "Table 7".
5.4.3.1
Setting through memorised transmitters
To activate the "PRESET/CUSTOM" function ("Figure 16"):
1.
press PRG once on the transmitter. The paired LED strip will flash
twice
2.
press PRG once on the transmitter. The paired LED strip will flash
twice
3.
press
o
4.
press
p
those available in "Table 4". If the
strip will flash three times, while if the
will flash four times. Release the pressed key.
3
16
1
(x 1)
6
PRG
4
x 2
(>3s)
( )
End

PRE-DEFINED (PRESET) OR PERSONALISED (CUSTOM) COLOURS/

INTENSITIES
Buttons
Table 3
p
x 3 s
q
x 3 s
for 3 s. The paired LED strip will flash twice. Release
for 3 s or
q
for 3 s to select the desired option among
p
key is pressed, the paired LED
q
2
3
(x 1)
PRG
x 2
x 2
x 3
(x 4)
Setting
PRE-SET colours (factory setting):
8 fixed pre-set colours – red, green,
blue, hot/cold white, cyan, yellow,
magenta.
CUSTOM colours: customisable by
the user (factory setting: blue).
o
key is pressed the LED strip
4
(>3s)
x 2
End
( )