Download Print this page

Section 2: Day-Burning; Section 3: Power Door Replacement (Easc) - GE Evolve Troubleshooting & Repair Manual

Led area light scalable fixtures eas
Hide thumbs Also See for Evolve:

Advertisement

Evolve™ LED Area Light
Scalable Fixtures (EAS)

Section 2: Day-Burning

When the Fixture will not shut off at daybreak when using a photocell controller,
this is called a day burner.
1. Replace photocell controller with a new or known good Photocell.
A. Unit will power off when Photocell is removed.
B. Install and Test Function of new photocell by covering the window with
Electrical tape or a glove.
C. If Photocell was defective the fixture should come on now and shut off when the
covering is removed.
2. If Replacing the Photocell does not resolve the issue, check the wiring in the fixture from the
Photocell Receptacle
Pull back gently on leads.
They should not disengage.
Terminals have tab that
must be seated in groove
inside of receptacle.

Section 3: Power Door Replacement (EASC)

• Disconnect and isolate incoming power to the fixture.
• Cut and strip input leads to LED Driver at the connectors
Troubleshooting