Goodman ComfortNet ASXC Series Service Instructions Manual page 79

Condensing units, split system heat pumps with r-410a refrigerant blowers, coils, & accessories
Table of Contents

Advertisement

SERVICING
S p ee d S ele ction D ip S witch es
C oo l
S ele ction
S witch es
T ap
1
2
A
O FF
O FF
B
O N
O FF
C
O FF
O N
D
O N
O N
TO SET A IRF L OW :
1.Select appropriate m odel from C ool ing/H eat P um p Airfl ow T able.
Bas ed on des ired Airflow f or y our ap plication select c orres ponding tap
(A ,B,C or D). Set d ip s witches 1 & 2 to the appropriate ON /O FF
positio ns.
2. Select appropriate Airflow adjustm e nt factor for applica tion
(0 %. + 10%, -10% ). Set dip sw itc hes 3 & 4 to the a ppropria te ON /OF F
positio ns.
3. If in stalled w it h He ater K it:
U sing El ectric H eat Airflow T able , set di p sw it ches 9, 10 and 11 t o the
appropriate O N/O FF pos itions ba sed on H eater k it instal led.
If ins tal led w ith out H eater Kit:
Ens ure d ip s witches 9, 10 and 1 1 are s et to a v alid heater kit sel ecti on.
Exam p le: T he only valid heat er k its for AVPT C 183014* appl ic ation s
ar e 3, 5, 6, 8 and 1 0 kW .
Fa ilu re to do so w il l r es ult i n a H eater Kit error c ode.
TO SET C OM F OR T M OD E:
Sele ct des ired C om fort M ode profil e (s ee profiles abo ve). Set s wi tches
5 and 6 to the approp riate ON /OF F position s.
Pre-Run
Short-Run
Profiles
A
-------
-------
30 sec/50%
B
C
-------
7.5 mins/82% 60 sec/100%
30 sec/50%
7.5 mins/82%
D
AVPTC Airflow Table
Ad ju st
S elec tio n
S w it che s
T R IM
3
4
O FF
O F F
0 %
O N
O F F
+ 1 0%
O FF
ON
- 10 %
O N
ON
0 %
Profile
Selection
Switches
Off Delay
5
-------
60 sec/100%
OFF
OFF
60 sec/100%
ON
OFF
OFF
ON
30 sec/50%
ON
ON
NOTE: When 8kW and 10kW heat kits are used with an
AVPTC1830 and AVPTC313, matched with 2-ton outdoor
unit, see Note 1below.
1 Set Heater Kit dip switches 9, 10 and 11 to 6kW setting
(9-ON, 10-OFF, 11-ON) to obtain 840 CFM.
AVPTC183014*
AVPTC313714*
AVPTC426014*
NOTE: Airflow data shown applies to non-communicating mode operation only. For a fully
communicating system, please see the outdoor unit's installation instructions for cooling and heat
pump airflow data. See ComfortNet™ System - Airflow Consideration section for details.
Htr kW
9
3
ON
5
ON
6
ON
8
ON
10
OFF
15
OFF
6
20
OFF
21
OFF
NOTE: Airflow data shown applies to the emergency heat mode (electric heat only) in either non-
communicating mode operation or fully communicating mode operation.
Cooling/Heat Pump Airflow Table
Model
Tap
A
B
C
A
B
C
D
A
B
C
D
Electric Heat Airflow Table
AVPTC
10
11
183014*
ON
ON
630
ON
OFF
730
OFF
ON
840
OFF
OFF
1080
ON
ON
1270
ON
OFF
NR
OFF
ON
NR
OFF
OFF
NR
Low
High
Stage
Stage
Cool
Cool
420
630
560
840
700
1040
410
610
560
830
700
1040
830
1240
810
1210
940
1410
1050
1560
1210
1800
AVPTC
AVPTC
313714*
426014*
610
600
710
680
840
790
1060
990
1260
1190
1470
1390
NR
1580
NR
1580
79