ACCESSORIES WIRING DIAGRAMS
AVPTC1830-3137 AND 4260
FL
HTR1
TL
PLM
BK
BK
1
2
RD
PU
3
BK
BL
4
M 1
R
5
M 2
W H
6
BK
7
BK
RD
8
9
L1
L2
ONE (1)ELEMENT ROWS
NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER
KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE
MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED.
40 VA TRANSFORMER, SEE NOTE 1
PL2
PL1
230 VAC
2
2
RD
RD
208 VAC
3
3
COM
1
BK
1
BK
6
6
WH
BR
5
5
BL
4
4
7
7
8
8
4 CIRCUIT HEATER
9
9
CONNECTOR
SEE
CFM LE D
NOTE
BK
7
DIAGNOSTI C
LE D
RD
1
2
3
4
STA TU S
LE D
LEAR N
SEE NO TE 6
TWO-STAGE INTEGRATED CONTROL MODULE
BL
GY
BK
RD
ECM MOTOR
HARNESS
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
106
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
FL
HTR2
TL
FL
TL
HTR1
RD
PLM
BK
BK
1
2
RD
PU
3
BK
BL
RD
4
M1
M3
RD
R
5
M2
M 4
BK
W H
6
RD
BK
7
BK
RD
8
9
L1
L2
L1
L2
TWO (2) ELEMENT ROWS
RD
3
GND
24 VAC
2
GN
1
BL
BL
RD
TR
TH
COM
FUSE
24 V
SE E
3 A
NOTE 5
DE HU M
O
Y2
Y1
DIP S W ITCHE S
W 2
W 1
G
C
RX LE D
R
2
1
CIRCULATOR BLOWER
GND
1
2
GN
3
4
5
RD
BK
FL
FL
FL
HTR1
TL
BK
FL
FL
TL
HTR2
RD
FL
FL
P L M
TL
HTR3
BK
1
2
YL
RD
YL
BK
PU
3
BL
BL
RD
M1
M3
M1
BL
4
YL
M2
M4
M2
RD
R1
R2
BR
5
BK
RD
BK
WH
6
BK
7
YL
8
BK
RD
9
L1
L2
THREE (3) ELEMENT ROWS
L1
L2
L1
L2
PROVIDED ABOVE.
L1
GND
DISCONNECT
INDOOR
AIR
CIRCULATOR
BLWR
208/230 VAC
L1
FUSE 3 A
TH
R
24 VA C
W1 (1)
W 1
HEAT SEQUENCER R1
W2 (2)
W 2
HEAT SEQUENCER R2
Y1
+VDC (1)
TO
Y2
RX (2)
MICR O
TX (3)
G
O
DEHUM
GND (4)
C
TR
COM
INT EG RA TED CONTROL MODUL E
COLOR CODES:
TL
HTR1
BK
PK PINK
TL
HTR2
RD
BR BROWN
TL
HTR3
YL
WH WHITE
P LM
TL
HTR4
BL
BK
1
BL BLUE
2
PU
GY GRAY
BK
RD
BL
3
RD
M1
M3
M5
M7
RD RED
BL
4
M2
M4
M6
M8
R1
R2
BR
5
YL YELLOW
RD
WH
6
OR ORANGE
7
YL
BL
PU PURPLE
8
BK
RD
9
GN GREEN
BK BLACK
FOUR (4) ELEMENT ROWS
LOW VOLTAGE (24V)
LOW VOLTAGE FIELD
HI VOLTAGE (230V)
HI VOLTAGE FIELD
L2
INTEGRATED CONTROL
EQUIPMENT GND
OVERCURRENT
PROT. DEVICE
PLUG CONNECTION
NOTES:
1. PLACE RED WIRES ON TRANSFORMER
TERMINAL 2 FOR 208 VAC OPERATION.
GND
2. MANUFACTURER'S SPECIFIED
REPLACEMENT PARTS MUST BE USED
L2
WHEN SERVICING.
40 VA
3. IF ANY OF THE ORIGINAL WIRES AS
TRANSFORMER
SUPPLIED WITH THIS UNIT MUST
BE REPLACED, IT MUST BE REPLACED
WITH WIRING MATERIAL HAVING A
TEMPERATURE RATING OF AT LEAST 105°C.
USE COPPER CONDUCTORS ONLY.
4. UNIT MUST BE PERMANENTLY
GROUNDED AND CONFORM TO N.E.C AND
LOCAL CODES.
5. TO RECALL THE LAST 6 FAULTS, MOST
RECENT TO LEAST RECENT, DEPRESS
INDOOR
SWITCH FOR MORE THAN 2 SECONDS
AIR
WHILE IN STANDBY (N THERMOSTAT
CIRCULATOR
BLWR
INPUTS)
6. BIAS AND TERM DIP SWITCHES MUST BE
IN "ON" POSITION. RED STATUS LED
PROVIDES NETWORK STATUS. GREEN RX
LED INDICATES NETWORK TRAFFIC. USE
LEARN BUTTON TO RESET NETWORK.
7. DISCARD CONNECTOR PL1 WHEN
INSTALLING OPTIONAL HEAT KIT.
GN D
JUNCTION
TERMINAL
INTERNAL TO
FIELD GND
FIELD SPLICE
RESISTOR
0140A00039-D