Putting into operation
When using high pressure hose extensions take care that the max.
length of 20 m is not exceeded!
Accessories may only be connected to a Kränzle-approved trigger gun
with safety catch.
20
3.
Release fixation of hose drum.
Unwind high pressure hose straight
and without nooses. Completely
unwind hose. The high pressure hose
may leave signs of abrasion on some
floors. Alternatively, please also find
non-marking high pressure hoses
in our range.
4.
Tightly screw together high pressure
hose and safety trigger gun.
5.
Lance on to safety trigger gun.
6.
Screw together lance and
safety trigger gun pressure tightly.
Putting into operation
Check the water inlet sieve for damage. Do not operate the
high pressure cleaner without or with a damaged filter.
Be careful when using hot water!
When running your high pressure cleaner with hot water of 60 °C raised
temperatures occur. Do not touch the metal parts of the high pressure
cleaner without safety gloves!
7.
Check water inlet filter for cleanliness
prior to putting the high pressure
cleaner into operation.
Manually unscrew plug-in coupling.
Take out the water inlet filter using
needle nose pliers and thoroughly
rinse it with clear water and clean
it with the other parts. If the sieve is
dirty, water cannot get through and
pressure will not build up.
8.
Connect the water hose to water
inlet sieve. The high pressure cleaner
may be connected to a water mains
(1-10 bar pre-pressure) with either
cold or hot water (up to 60 °C).
The small quadro series provides the
opportunity of sucking in water out
of a container (see direct suction).
9.
Each time check oil level at the oil
dipstick prior to putting the high
pressure cleaner into operation.
Oil level must reach until the upper
edge of marking "OK".
21