Can I use my Fireplace during power outages?
This ignition system utilizes thermocouple and thermopile power for pilot and burner ignition functions. AC power is utilized for
blower function only. If the AC power is interrupted during a power outage, you may operate this fireplace for one continuous
hour on and one continuous hour off cycles only.
During the power outage, the appliance's burners will function. In addition, Flame Height adjustment function will be available.
The Fan, which is wholly dependent on 110VAC power, will not function.
5.7 WHAT MAINTENANCE IS REQUIRED?
Required Annual Maintenance
The following procedures must be performed each year by a qualified installer, service agency or the gas supplier.
Note: Any adjustments to burner, pilot or logs must be done by a qualified installer, service agency or the gas supplier.
Recommended steps for yearly maintenance:
1. Clean all lint and dust build-up around the control. Inspect the condition of any wiring under the burner for melting or
damage.
2. Clean pilot thermocouple, thermopile and sparker rod using emery cloth. Vacuum clean pilot light assembly.
3. Visual check of pilot flames is required. Pilot flame must overlap thermocouple tip and burner ignition ports always.
Especially for LP gas applications, always verify visible pilot flame length is at least 1" long.
4. Vacuum all burner ports. Be sure the burner ports are "open".
5. Visual check of main burner's rear and front flames is required.
6. Remove logs and coals and clean away any foreign matter (lint, carbon, etc.) on the burner and logs.
7. Clean under side of the logs for any carbon deposits. Note: Logs should be visually checked for carbon buildup. If carbon
deposits are visible on logs, unit should be turned off and a qualified installer, service agency or the gas supplier
contacted. Be sure logs are re-installed per instructions.
8. Check condition of glass door gasket, gasket must seal tightly over firebox. Inspect gasket along top and sides of glass. If
gasket bulb along top edge or side top areas are discolored to a white color appearance (through the whole thickness of
the gasket bulb in a 3" to 12" long area) and the gasket adhesive in no longer functional to stick to glass, then replace the
gasket.
9. Visually inspect the vent terminal (vent cap) for leaves, twigs and other debris accumulation. Clean if required.
10. Clean door glass.
Periodic Inspection
Follow these steps for periodic inspections:
1. Check to verify that the vent system and vent cap are open and free of blockage.
2. Before re-installing glass, have qualified service person check the operation of the pilot and cycle the burner per lighting
instructions. Be sure all items in lighting and installation checklists are completed.
3. Periodic visual check of pilot flames is required. Pilot flame must overlap thermocouple tip and burner ignition ports
always. Especially for LP gas applications, always verify visible pilot flame length is at least 1" long.
4. Periodic visual check of main burner's rear and front flames is required.
How do I clean the viewing glass?
The viewing glass should be cleaned periodically. Exterior glass surface may be cleaned with cleaner as desired. To clean interior
glass surface, use Kel Kem Polish Plus (part # 65-06-00455) or a comparable product. Caution: Do not use ammonia-based
cleaners or oven cleaner to clean glass. Clean the glass only when it has cooled to room temperature.
Additives that are put in gas (both natural and propane) to make it smell can be harmful to glass and can
leave a white film deposit on the glass. This deposit can be removed, if cleaned in a timely manner, with
cleaners such as KEL KEM "Polish Plus" (part # 65-06-00455) or comparable product (contact your dealer).
Is my flame performance correct?
Your fireplace has air shutters, dampers, coals, and embers that can be adjusted depending on your fuel and venting
configuration. These adjustments should be made by a qualified technician to achieve the best flame performance. Contact your
85-03-01117