1. Safety Instructions

Please read the instructions carefully as they include important
information about installation, usage and maintenance.
WARNING
Please keep this User Guide for future consultation. If you sell the unit to
another user be sure that they also receive this.
Unpack and check carefully that there is no transportation damage before
using the unit.
Ÿ Before operating, ensure that the voltage and frequency of the power supply
match the power requirements of the unit.
Ÿ It's important to ground the yellow/green conductor to earth in order to avoid
electric shock.
Ÿ The unit is for indoor use only. Use only in a dry location.
Ÿ The unit must be installed in a location with adequate ventilation, at least
50cm from adjacent surfaces. Be sure that no ventilation slots are blocked.
Ÿ Disconnect the mains power before replacement or servicing.
Ÿ Make sure there are no flammable materials close to the unit while operating
as they may cause a fire hazard.
Ÿ Always use a safety cable when installing this unit.
Ÿ The maximum ambient temperature is: 40°. Don't operate it where the
temperature is higher than this.
Ÿ In the event of a serious operating problem stop using the unit immediately.
Never try to repair the unit by yourself. Repairs carried out by unskilled
people can lead to damage or malfunction. Please contact the nearest
authorized technical assistance center. Always use the same type spare
parts.
Ÿ Do not touch any power cables during operation as the high voltage may
cause an electric shock.
Warning
Ÿ To prevent or reduce the risk of electrical shock or fire, do not expose the unit
to rain or moisture.
Ÿ Do not open the unit within five minutes after switching off.
Ÿ The housing and lenses must be replaced if they are visibly damaged.
Ÿ This lighting fixture is for professional use only - it is not designed for or
suitable for household use. The product must be installed by a qualified
technician in accordance with local territory regulations. The safety of the
installation is the responsibility of the installer. The fixture presents risks of
severe injury or death due to fire hazards, electric shock and falls.
Ÿ Warning! Risk Group 2 LED product according to EN 62471.
Do not view the light output with optical instruments or any device
that may concentrate the beam.
Ÿ WARRANTY: One year from date of purchase.
Installation
The unit should be mounted via its screw holes onto the bracket. Always
ensure that the unit is firmly fixed to avoid vibration and slipping while operating.
Make sure that the structure to which you are attaching the unit to is secure
and is able to support a weight of 10 times of the unit's weight. Always use a
safety cable that can hold 12 times of the weight of the unit when installing the
fixture.
The equipment must be installed by professionals and it must be installed in a
place where is out of the reach of people and no one can pass by or under it
2. Features and Technical Specifications
l
Control: I.R., Sound active, Auto, Master/slave and DMX 512 modes
l
DMX Channels: 2CH/3CH/4CH/7CH
l
Optional IR Remote (LEDJ90C)
l
Electronic dimming 0-100% and variable strobe
l
Beam angle: 40°
l
4 push button menu with LED display
l
Voltage: AC100-240V 50/60Hz
Fuse: T2.5A 250V
l
l
Power Consumption: 30W
l
Light source: 5 x 5W quad-colour LEDs (RGBUV)
l
Dimensions: 205 x 230 x 115mm