    10000W Generator Table of Contents Topic Page Safety Guidelines General Precautions General Parts Battery Operation Inspection, Cleaning and Maintenance Installation Troubleshooting Specifications Wiring Diagram...
  • Page 3: Safety Guidelines

    Safety Guidelines - Definitions This manual contains important information that you need to know and understand in order to protect YOUR SAFETY and to PREVENT EQUIPMENT PROBLEMS. The following symbols help you recognize this information. Please read the manual and pay attention to these sections. Save These Important Safety Instructions! Read and understand all of these safety instructions.
  • Page 4: General Precautions

    7500W Generator General Precautions WARNING! FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN SEVERE INJURY OR DEATH. CAUTION: FAILURE TO FOLLOW THESE INSTRUCTIONS CAN ALSO RESULT IN DAMAGE TO THE TOOL AND/OR THE ITEM YOU ARE WORKING Carbon Monoxide When this tool is running, ensure that the area is well ventilated. Never run the engine in an enclosed area.
  • Page 5 CAUTION: ATTEMPTING TO POWER SENSITIVE ELECTRONIC EQUIPMENT WITHOUT THE USE OF AN APPROVED LINE CONDITIONER MAY CAUSE DAMAGE TO THE EQUIPMENT. PULSAR PRODUCTS INC.IS NOT RESPONSIBLE FOR ANY DIRECT OR INDIRECT DAMAGE CAUSED BY FAILURE TO USE AN APPROVED LINE CONDITIONER.
  • Page 6 7500W Generator General Precautions Work Area • Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents. • Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. Generators create sparks which may ignite the dust or fumes. •...
  • Page 7 Owner’s Manual General Precautions Electrical Safety • All connections and conduits from the generator to the load must only be installed by trained and licensed electricians, and in compliance with all relevant local, state, and federal electrical codes and standards, and other regulations where applicable. •...
  • Page 8 7500W Generator General Precautions Personal Safety • Avoid accidental starting. Make sure the power switch is in its “OFF” position and disconnect the spark plug wire when not in use. • Remove adjusting keys or wrenches before turning the generator on. A wrench or a key that is left attached to a rotating part of the generator may result in personal injury.
  • Page 9 Servicing Maintain labels and name plates on the generator and engine. These carry important information. If unreadable or missing, contact Pulsar Products Inc. Immediately for a replacement. Generator service must be performed only by qualified repair personnel. Service or maintenance performed by unqualified personnel could result in a risk of injury.
  • Page 10 7500W Generator General Precautions Installation • If the generator is installed outdoors, it must be weatherproofed and should be soundproofed. It should not be run outdoors without protection to the generator and wiring conduit. • The generator weighs lbs (approximately) . Two or more people should assist when moving or lifting this product.
  • Page 11 Owner’s Manual General Precautions Mechanical • Do not operate the generator with safety guards removed. While the generator is running, do not attempt to reach around the safety guard for maintenance or any other reason. • Keep hands, arms, long hair, loose clothing, and jewelry away from moving parts. Be aware that when engine parts are moving fast they cannot be seen clearly.
  • Page 12: General Parts

    Owner’s Manual Ge n ra l Pa s Frame Fuel tank cap Fuel gauge One way valve Fuel tank Engine Switch Choke lever Control Panel Air filter Wheel Handle Fuel valve Recoil starter Battery Oil dipstick Fuel Selector Switch Voltage frequency Thermal protector hour meter 120V/240V...
  • Page 13: Battery

    7500 W Ge n erato r Battery AC electrical To start generator with electric start you will need a battery (included) . Also this generator can also be started with the pull start. Note: Using a battery not designed for this unit may void warranty.
  • Page 14: Operation

    Operation NOTE: THE PARTS LISTED ABOVE ARE HELPFUL FOR LOCATING THE CONTROLS MENTIONED BELOW. CAUTION: PRIOR TO FIRST USING THE GENERATOR, THE ENGINE MUST BE FILLED WITH A HIGH QUALITY SAE 10W30 GRADE ENGINE OIL. TO DO SO, UNSCREW AND REMOVE THE ENGINE’S OIL DIPSTICK LOCATED AT THE BOTTOM OF THE ENGINE CRANKCASE.
  • Page 15 Operation Connecting to LPG Fuel Source 1.Locate the LPG converter on the backside of the generator 2.Attach small end of the Gas Hose to the LPG converter. 3.Connect gas hose to propane fuel source. Do not turn on propane source prior to following the steps outlined.
  • Page 16 Operation Starting the Generator Set Ground Terminal Before using generator, a ground wire must be connected to the ground terminal. The Ground terminal is located on the Front Panel. Before using the ground terminal consult a qualified electrician. Ground Terminal Symbol: The 7750Watt dual fuel generator can be started using the following method.
  • Page 17 Operation RECOIL START METHOD 1. Disconnect all devices from the outlets on the generator panel. 2. Press the engine switch to the "ON" position. 3. Grasp the recoil starter handle and pull it until the engine starts. Do not allow the recoil starter to snap back. Return it slowly by hand 4.
  • Page 18 Operation If electric start does not turn on the generator after three attempts, contact customer support. Repeated attempts could damage the ignition mechanism. 3. Follow steps 6-7 from the Recoil Start Method Using the Generator Set 1. Turn off the switches of the device before connecting to the generator. 2.
  • Page 19 Operation Stopping the Generator Set When using gasoline 1.Turn off all the connected devices. 2.Allow the generator set run for a few minutes to cool down. 3.Stop the generator set by pressing and holding the engine switch in the OFF position until the generator set stops. 4.Rotate the fuel valve lever back to the OFF position.
  • Page 20 CAUTION: ATTEMPTING TO POWER SENSITIVE ELECTRONIC EQUIPMENT WITHOUT THE USE OF AN APPROVED LINE CONDITIONER MAY CAUSE DAMAGE TO THE EQUIPMENT. PULSAR PRODUCTS INC. IS NOT RESPONSIBLE FOR ANY DIRECT OR INDIRECT DAMAGE CAUSED BY FAILURE TO USE AN APPROVED LINE CONDITIONER.
  • Page 21 7500W Generator Operation Powering 12 Volt DC tools and Equipment: 1. Prior to powering tools and equipment, make sure the generator’s rated voltage, and amperage capacity (12VDC) is adequate to supply all electrical loads that the unit will power. If powering exceeds the generator’s capacity, it may be necessary to group one or more of the tools and/or equipment for connection to a separate generator.
  • Page 22 Operation Spark Plug Service In order to service the spark plug, you will need a spark plug wrench (commercially available). Recommended spark plugs: NHSP LD F7TC. To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. 1.
  • Page 23: Inspection, Cleaning And

    Inspection, Cleaning, and Maintenance WARNING! ALWAYS MAKE SURE THE ENGINE POWER SWITCH (2) IS IN ITS “OFF” POSITION. DISCONNECT THE SPARK PLUG WIRE FROM THE ENGINE. AND ALLOW SUFFICIENT TIME FOR THE ENGINE AND GENERATOR TO COMPLETELY COOL BEFORE PERFORMING ANY INSPECTIONS, MAINTENANCE, OR CLEANING.
  • Page 24: Maintenance Installation

    7500W Generator Installation NOTE: PRIOR TO POWERING TOOLS AND EQUIPMENT MAKE SURE THE GENERATOR’S RATED VOLTAGE, WATTAGE AND AMPERAGE CAPACITY IS ADEQUATE TO SUPPLY ALL ELECTRICAL LOADS THAT THE UNIT WILL POWER. IF POWERING EXCEEDS THE GENERATOR’S CAPACITY, IT MAY BE NECCESSARY TO GROUP ONE OR MORE OF THE TOOLS AND/OR EQUIPMENT FOR CONNECTION TO A SEPERATE GENERATOR.
  • Page 25 Installation Supporting and Mounting Mount the generator on a concrete slab capable of supporting the weight of the generator. The slab must extend on all sides beyond the frame by at least one foot. Contact a cement contractor for slab specifications if necessary. Attach the frame to the concrete slab using 3/8” diameter expansion anchor bolts (not supplied).
  • Page 26: Troubleshooting

    Troubleshooting Note: Troubleshooting problems may have similar causes and solutions. PROBLEM POSSIBLE CAUSE SOLUTION Is there fuel in the tank? Refill the fuel tank. Is there enough oil in the The engine Add the recommended oil. engine? will not start Is the spark plug in good Readjust gap and dry the spark plug.
  • Page 27: Specifications

    7500 W Ge n erato r Specifications P G10000B Model 10kW M ax.Power R ated Power AC output Frequency 60Hz 120V / 240V Voltage Power Factor Engine Model DHLG420 Type 4 Strokes / Air Cooling / Single Cylinder / OHV/ Horizontal Shaft Displacement(cc)
  • Page 28: Wiring Diagram

    Wiring Diagra Shop for quality Pulsar products on our website. On our website you can discover more about Generators.