Pulsar PG105TiSRCO Operator's Manual

10500 watt tri-fuel inverter generator

Advertisement

Quick Links

10500 Watt Tri-Fuel Inverter Generator
OPERATOR'S MANUAL
Warning: The Engine Exhaust from this product contains chemicals known to
the State of California to cause cancer, birth defects or other reproductive harm.
Model: PG105TiSRCO
DO NOT RETURN TO STORE!
STOP
HAVE QUESTIONS OR NEED SERVICE?
866-591-8921
support@pulsar-products.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PG105TiSRCO and is the answer not in the manual?

Questions and answers

Summary of Contents for Pulsar PG105TiSRCO

  • Page 1 Model: PG105TiSRCO 10500 Watt Tri-Fuel Inverter Generator OPERATOR’S MANUAL DO NOT RETURN TO STORE! Warning: The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. STOP HAVE QUESTIONS OR NEED SERVICE? 866-591-8921 support@pulsar-products.com...
  • Page 2: Table Of Contents

    It means to pay attention and be alert, your safety is involved! Please read and abide by the message that follows the Pulsar Products reserves the right to make updates to this manual safety alerts symbol. at any time.
  • Page 3: Safety Instructions

    Safety Instructions Safety Precautions Before operating your generator, you must read and understand the manual and familiarize yourself with the safe operation practices. SYMBOL DESCRIPTION Safety Alert Symbol Electrocution Hazard Asphyxiation Hazard WARNING POISONOUS GAS HAZARD: Engine exhaust contains carbon Burn Hazard.
  • Page 4 Safety Instructions WARNING Correct Usage Example location to reduce risk of carbon monoxide poisoning • ONLY use outside and downwind, far away from windows, doors, and vents. Fuel and its vapors are extremely flammable and explosive which • Direct exhaust away from occupied spaces. could cause burns, fire, or explosion resulting in death or serious injury and/or property damage.
  • Page 5: Carbon Monoxide Safety

    • If you have questions about intended use, ask a dealer or tests the air for dangerous levels of carbon monoxide. If dangerous contact your local Pulsar service center. levels of carbon monoxide are detected this generator will • Operate generator only on solid, level surfaces.
  • Page 6: Names Of Components

    Components Before operating your generator, you must read and understand the manual and familiarize yourself with the safe operation practices. Operator Position 1. Fuel Cap: Add gasoline here. 2. Left Side Panel: Engine, Air Filter, Carburetor, Spark Plug. 3. Transport Wheels 4.
  • Page 7: Control Panel

    1. Battery Switch: Turns battery ON and OFF. Must be ON before electric start or remote start. 2. USB Ports: USB Type A 5V/3.6A, 9V/2.5A, 12V/2A and USB Type C. 3. Parallel Connectors: A compatible Pulsar Inverter Generator can be connected for additional power output. 4. ATS Interface: For connecting to ATS control box.
  • Page 8: Specifications

    Specifications Model PG105TiSRCO Engine Type Single Cylinder, Four Stroke, Air Cooled Gasoline Engine Displacement 457cc Rated Power (kW) Gasoline Peak Power (kW) Gasoline 10.5 Rated Power (kW) LPG/Propane Peak Power (kW) LPG/Propane Rated Power (kW) NG/Natural gas Peak Power (kW) NG/Natural gas...
  • Page 9: Assembly

    Assembly Preparation Your generator requires some assembly. This generator ships from our factory without oil; it must be properly filled with oil before operation. Unpacking 1. Set the shipping carton on a solid, flat surface. 2. Remove everything from the carton except the generator. 3.
  • Page 10: Preparation

    Preparation WARNING Preparation The generator battery is shipped disconnected for NON-SPILLABLE SEALED BATTERY safety. You must connect the battery quick-connect cables before using the generator. This is a ready Connecting the battery filled, activated sealed battery. • A quick connect battery plug is pre-installed on the Never remove battery and the generator, connect both together as strip.
  • Page 11: Add Engine Oil

    Preparation 1. Place the generator on a solid, flat, level surface. Preparation 2. On the right side of the generator, loosen the screws and remove the maintenance cover. Your generator requires some assembly. This generator ships from our factory without oil; it must be properly filled with oil before operation.
  • Page 12 Preparation NOTICE 4. Replace the fuel cap and wipe up any spilled gasoline with a dry cloth then remove the cloth from the area. Check oil level often during the break-in period. Refer to the DANGER Maintenance section for recommended service intervals. CAUTION Do not overfill the gasoline the tank.
  • Page 13: Connecting A Lpg Tank

    If the leak continues or if the leak is not at a fitting then DO NOT use the generator and contact an authorized Pulsar service Explosion hazard. DO NOT start generator if you smell propane.
  • Page 14: Connecting A Ng Hose

    • Never use a natural gas supply line, natural gas hose, or any other fuel item that appears to be damaged. Connecting Natural Gas 1. Pulsar Products requires that this gas connection shall only be performed by a licensed gas contractor!In some locations this is required by law.
  • Page 15: Grounding The Generator

    Preparation Grounding The Generator Attach grounding wire (if required by code) • Ground the generator by connecting a suitable grounding cable to the grounding stud on the panel and tighting the nut. • Connect the other end to a copper or brass grounding rod that's driven into the earth.
  • Page 16: Operation

    Operation Generator Location Starting The Generator WARNING 1. Make sure the generator is on a solid, flat, level surface. 2. Disconnect all electrical loads from the generator. Never start NEVER operate the generator inside any building, garage, or stop the generator with electrical loads connected. basement, crawlspace, shed, or enclosure, including the 3.
  • Page 17: Parallel Operation

    Operation DANGER 6. For Recoil Start Recoil Start: Firmly grasp and pull the recoil handle slowly until you feel resistance, let it retract then pull swiftly. If it fails to Fire and explosion hazard. Always turn the propane tank valve to start successfully, wait for 3 seconds then repeat this step.
  • Page 18: Low Oil Indicator

    Restart the engine and reconnect devices while being careful to not overload the generator. Any generator will produce less power at high altitudes and/or in hot weather. Please contact Pulsar Support at 866.591.8921 2. Press and hold the START/STOP button for 1-3 seconds to stop for details.
  • Page 19: Generator Capacity

    Operation Generator Capacity High Altitude Operation NOTICE At high altitude, the standard carburetor air/fuel mixture will be too rich. Performance will decrease, and fuel consumption will Do not overload the generator's capacity. Exceeding your increase. A very rich mixture will also foul the spark plug and generator's wattage capacity can damage the generator cause hard starting.
  • Page 20: Maintenance

    Maintenance WARNING Turn the generator “OFF”, wait for the engine to cool, and disconnect the spark plug cable before performing any inspection, maintenance, or cleaning procedures. EQUIPMENT FAILURE: Do not use damaged equipment. If abnormal noise, vibration, or excess smoking occurs, have the problem corrected before further use.
  • Page 21: Checking And Filling Fuel

    Maintenance 3. Place an oil drain pan under the generator and center it under Checking and Filling Fuel the oil drain opening. WARNING 4. Remove the right access panel and set it aside. Locate the folded rubber drain tube from the bottom of the engine. Unfold this drain tube, unscrew the cap, and tilt the generator so that TO PREVENT SERIOUS INJURY FROM FIRE: the oil drains into an approved container.
  • Page 22: Air Filter Maintenance

    Maintenance Air Filter Maintenance WARNING 1. Loosen the screw and remove the left panel to access the air TO PREVENT ACCIDENTAL BRUSH FIRE, secure spark arrestor filter. back in place immediately after cleaning and before further operation. 2. Remove Air Filter Cover- see figure below. 3.
  • Page 23 Maintenance NOTICE 3. Draining the Carburetor for Generator Storage: Use only BPR6ES (NGK) type spark plug or equivalent. Using After closing the Fuel Valve, place an appropriate container under an incorrect spark plug may damage the engine. the Carburetor and carefully remove the Drain Bolt from the bottom of the Carburetor Bowl, allowing the fuel to drain completely.
  • Page 24: Troubleshooting

    Troubleshooting Problem Cause Solution Engine is running, but AC output is 1. Open circuit breaker 1. Reset circuit breaker not available 2. Poor connection 2. Check and repair 3. Defective cord set 3. Check and repair 4. Connected device is faulty 4.

Table of Contents