INCORPORATED
Owner's Manual Addendum New GFCI Receptacle
Hubbell GFRST15W GFCI Receptacle (w/Automatic Self-Test)
Due to a UL943 change that requires all GFCI receptacles manufactured after June 29, 2015 to automatically
self-test, we had to change the GFCI receptacle on our inverters.
The new Hubbell GFRST15W GFCI receptacle (Vanner P/N 07115) requires 120Vac to be present when
manually testing or resetting the device. On Vanner quasiwave inverters with load demand active, you will need
to turn off the inverter and then turn the inverter back on to reset the GFCI receptacle within 5 seconds before
the inverter goes back into load demand mode. You can also disable the load demand mode via dipswitch, if
applicable.
LED Function – The Green LED will be on when A/C power (120 volts) is present to the GFCI.
The Red LED will be on solid in addition to the Green LED when the GFCI protection has been activated.
If the Red LED is flashing the receptacle has lost its GFCI protection and shall be replaced immediately.
Contact Sales or Service 1-800-AC-POWER (1-800-227-6937).
Note: The Bybon BYB-E15 GFCI will also be used on our inverters.