Fig 71-72-73-74
2mm behind the blade
SETTING UP THE SAW/OPERATING INSTRUCTIONS
F
G
Step 4 Re-tighten the Hex screw (F), see fig 72. When all
adjustments have been made, recheck that when the blade is
pressed back against the thrust bearing, both the upper and
lower side guides are still behind the teeth of the saw. When all
adjustments are complete, close both upper and lower doors
and clear away all tools around the machine.
Step 5 Re-connect the power, move the 'Electro-magnetic
motor brake selector switch' to the run position (2), see fig 75
and press the 'GREEN' button to start the saw. Allow the
bandsaw to run for several minutes, check that the blade is
still tracking correctly, there is no excessive vibration, etc. After
several minutes switch off and allow the blade to come to a
complete stop.
DISCONNECT THE SAW FROM THE
MAINS SUPPLY!
General Operating Instructions
1. Make sure you have read and fully understood the general
instructions and safety precautions that are printed in the
preceding pages of this manual.
2. Before connecting the machine to the supply; check
the machine for obvious signs of damage, paying particular
attention to the plug and the power cable. Rectify or have
rectified any damage you discover. Check that the blade
you are using is the correct one for the job in hand. Change
the blade if necessary. Check the blade is not damaged; is clean,
sharp, tracks properly and is correctly tensioned.
3. Set the upper blade guide to approximately 12mm (1/2")
above the height of the work piece.
4. Check, especially on site, that there are no foreign objects e.g.
old nails, screws, small stones etc embedded in the material you
are about to cut.
25
Fig 75