Installation Procedure - Pico Macom DSP806 Installation And Operation Manual

806mhz agile pll saw-filtered digital-analog channel processor
Table of Contents

Advertisement

Adherence to these precautions will help prevent
problems during initial installation of the DSP806.
When connecting the DSP806 directly to a TV set, attenuate the output sufficiently to pre-
WARNING:
vent overdriving the TV set. The input level to the TV should be 5 dBmV.
1. Connect the I.F. jumper from the I.F. output to the I.F. input on the rear panel.
2. Connect the DSP806 to a 115 VAC grounded receptacle. Observe the lit LED light indicating power is on.
3. Connect the antenna input signal and check the level at the input test point using a signal level meter or spectrum analyzer. The level
must be at 0 dBmV minimum for a minimum carrier to noise ratio of 45 dB.
4. Connect the signal level meter or spectrum analyzer to the -30dB TEST POINT (front panel) and adjust the output level control to
desired level.
5. Verify performance by connecting a TV to the output test point or through an attenuator (50 dB) to the RF output. The input level to
the TV should be 0 to 10 dBmV maximum.
RF IN
(ANTENNA INPUT, 0 dBmV MINIMUM)
RF OUT (TO TV)
RF OUT
I.F.LOOP
40dB ATTENUATOR
(FAM-20, 2 PCS.)
Ph:800-421-6511

Installation Procedure

DSP806
IF IN
IF OUT
RF IN
CAUTION:
FOR CONTINUED PROTECTION AGAINST FIRE
HAZARD, USE ONLY WITH SAME TYPE 0.5A 125V FUSE
www.picomacom.com
ANTENNA
125V
117 VAC
0.5A
600W MAX
60 Hz 35 W
FUSE