Minimum rpm CH
c.
Activation external power saving switch
input
d
Minimum rpm hot water
E
Min. leaving water temperature at OT
(OpenTherm) or RF thermostat
E.
Reaction OT and RF room thermostat
F
Start rpm CH
F.
Start rpm hot water
h
Max. rpm fan (* 100 rpm)
n
Regulated temperature during boiler
operation (Ta)
n.
Hot water temperature at Comfort/Eco
O.
Wait time CH request response
o
Waiting time CH operation after hot water
operation
o.
Number of eco days
P
Anti-recycling time during CH operation
P.
Reference value hot water
q
Summer mode
ROTEX Heating Systems GmbH
30
30
30
Settings reach 20 – 50% (40%=propane)
40
40
40
Setting range 0,15 – (value parameter c. )
0 = external power saving switch activated
Other values : Min. capacity modulating pump.
25
25
25
Settings reach 20 – 50% (40%=propane)
40
40
40
Settings reach 10 – 60°C
1
1
1
0= do not respond to hot water request if requested temperature
is lower than the set value par. E
1= respond to hot water request with minimum leaving water
temperature limited to set value par. E
2= respond to hot water request with maximum leaving water
temperature (on/off function)
70
70
70
Settings reach 50 – 99% of the set maximum rpm
(propane=50%)
70
70
70
Settings reach 50 – 99% of the set maximum rpm
(propane=50%)
45
46
46
Settings reach 40 – 50 (RHOB12AAV1H, RHOB18AAV1H and
RHOB42AAV1H)
This parameter can be used to set the maximum rpm
85
85
85
Setting reach 60°C - 90°C
0
0
0
Setting reach: 0 or 40°C – 60°C
0= reheating temperature is equal to hot water temperature
0
0
0
Settings reach 0 – 15 minutes
0
0
0
Settings reach 0 – 15 minutes
3
3
3
Settings reach 0, 1 – 10
0 = Comfort function controllable by Open Therm room
thermostat
1 – 10 number of eco days
5
5
5
Minimum switch off time on CH operation
Can be set to 0 – 15 minutes
24
30
36
0 = Flow switch applicable
24 = RHOB12AAV1H
30 = RHOB18AAV1H
36 = RHOB42AAV1H
0
0
0
0 = Summer mode deactivated
1 = Summer mode to be activated by
(code in display : Su)
2 = Summer mode to be activated by
(code in display : So)
3 = Summer mode to be activated by
(code in display : Et)