To Connect The Wlan Cartridge (Delivered As Accessory); To Connect The Solar Input - Daikin ETSXB16E7 Installation Manual

Hide thumbs Also See for ETSXB16E7:
Table of Contents

Advertisement

X 1 5 M
K1A
K2A
3 4 5 6
X 5M
1
X12M.23
X15M.3
X15M.4
X12M.24
X15M.5
X15M.6
4 Connect the low voltage wiring as follows:
A
B
5
9 10
X 5M
1
5 Connect the high voltage wiring as follows:
ETSH/X(B)16P30+50E
Daikin Altherma 3 H HT ECH₂O
4P679468-1B – 2022.09
X 1 2 M
23 24 25
X
12
M
X12M.25
X12M.25
X 5M.10
1
S4S
X 5M.9
1
A
B
A
B
6 Fix the cable with cable ties to the cable tie mountings. General
information, see
"6.3.1  To connect the electrical wiring to the
unit" [ 4  17].
indoor
6.3.14
To connect the WLAN cartridge (delivered
as accessory)
[D] Wireless gateway
1 Insert the WLAN cartridge into the cartridge slot on the user
interface of the indoor unit.
6.3.15

To connect the solar input

Wires: 0.5 mm²
Solar input contact: 5 V DC (voltage supplied by PCB)
6 Electrical installation
23
24 25
X 2M
1
L1
N
L2
N
1
2
A
Installation manual
B
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Altherma 3 h ht ech2oEtsh16e7

Table of Contents