Electrical installation

9.3.11 To connect the WLAN cartridge (delivered as accessory)

9.4 After connecting the electrical wiring to the indoor unit

Installer reference guide
114
A
1
High voltage Smart Grid contact 1
2
High voltage Smart Grid contact 2
B
A
B
4 Fix the cables with cable ties to the cable tie mountings. If necessary, bundle
excessive cable length with a cable tie.
1 Insert the WLAN cartridge into the cartridge slot on the user interface of the
indoor unit.
2
To prevent water ingress to the switch box, seal the low voltage wiring intake using
the sealing tape (delivered as accessory).
X10M.1
L
1
X10M.2
N
X10M.3
L
2
X10M.4
N
X10M
1 2 3 4
X5M