Parameter Overview - Setting Ranges; Tig Welding; Mma Welding - EWM Tetrix 451 AC/DC AW FW Operating Instructions Manual

Welding machines and accessories
Hide thumbs Also See for Tetrix 451 AC/DC AW FW:
Table of Contents

Advertisement

Appendix B
11
Parameter overview – setting ranges
11.1

11.1.1 TIG welding

Parameter
TIG/plasma
Gas pre-flow time
Ignition current AMP%
Up-slope time
Pulse time
Slope time
Secondary current AMP%
Pulse pause time
Slope time
Down-slope time
End current AMP%
Gas post-flow time
Electrode diameter, metric
spotArc time
spotmatic time (
spotmatic time (
activArc
Up/down speed
Current jump

11.1.2 MMA welding

Parameter
MMA
Hot start current
Hot start time
Arcforce
Pulse frequency
Pulse balance
099-000115-EW501
20.11.2017
Display
s
%
s
s
s
%
s
s
s
%
s
mm 2,4
s
>
)
ms
>
)
s
%
A
Display
%
s
Hz
Parameter overview – setting ranges
Setting range
Comment
0,5
0
-
20
20
1
-
200
% of main current AMP
1,0
0,0
-
20,0
0,01
0,00 -
20,0
0,10
0,00 -
20,0
Time from main current AMP to
secondary current AMP%
50
1
200
% of main current AMP
0,01
0,00 -
20,0
0,10
0,00 -
20,0
Period from secondary current
AMP% to main current AMP
1,0
0,0
-
20,0
20
1
-
200
% of main current AMP
8
0,0
-
40,0
1,0
-
4,0
2
0,01 -
20,0
200
5
-
999
2
0,01 -
20,0
0
-
100
10
1
-
100
x0.01% of main current AMP
1
1
-
20
Setting range
Comment
120
1
-
200
% of main current AMP (set
parameter
0,5
0,0
-
10,0
0
-40
-
40
1.2
0.2
-
500
30
1
-
99
Appendix B
to
)
129

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tetrix 351 ac/dc aw fwTetrix 551 ac/dc aw fw

Table of Contents