Table 2-1
BIOS Error Codes, Messages, and Beeps List
BIOS Error Codes,
Messages, beeps
NOTE: To diagnose a problem, first find the BIOS error messages, codes,
or beeps in left column. If directed to a check procedure, replace the FRU
indicated in the check procedure. If no check procedure is indicated, the first
Action/FRU listed in right column is the most likely cause.
1780
Primary master hard disk
failure
1781
Primary slave hard disk failure
1782
Secondary master hard disk
failure
1783
Secondary slave hard disk
failure
8602
Mouse error on no Mouse
present
SYSTEM HALTED, (CTRL-
ALT-DEL) TO REBOOT ...
Hard Disk(s) failure (80)
Hard Disk(s) failure (40)
Hard Disk(s) failure (20)
Hard Disk(s) failure (10)
Action/FRU
A warning message to indicate there has
been change of IDE Primary (Secondary)
Channel Master (Slave) device.
Load default settings in Setup.
Check IDE drive jumper. See "3.5-In. Hard
Disk Drive Jumper Locations" on page 5-11.
IDE drive power.
IDE drive cable/connection.
IDE drive.
A warning message to indicate there has
been change of IDE Primary (Secondary)
Channel Master (Slave) device.
Load default settings in Setup.
Check IDE drive jumper. See "3.5-In. Hard
Disk Drive Jumper Locations" on page 5-11.
IDE drive power.
IDE drive cable/connection.
IDE drive.
Make sure the Mouse is connected properly
and are set correctly in BIOS Setup.
Mouse.
System board.
Indicates the present boot attempt has been
aborted and the system must be rebooted.
Press and hold down the CTRL and ALT
keys and press DEL.
Hard Disk Drive reset failed.
Hard Disk Drive controller diagnostics failed.
Hard Disk Drive initialization error.
Unable to recalibrate fixed disk.