IBM Aptiva 2187 Service Manual page 72

Service level a
Table of Contents

Advertisement

Table 2-1
BIOS Error Codes, Messages, and Beeps List
BIOS Error Codes,
Messages, beeps
NOTE: To diagnose a problem, first find the BIOS error messages, codes,
or beeps in left column. If directed to a check procedure, replace the FRU
indicated in the check procedure. If no check procedure is indicated, the first
Action/FRU listed in right column is the most likely cause.
201
Memory test failure.
301
Keyboard error or no keyboard
present.
662
FLOPPY DISK(S) failure (80)
662
FLOPPY DISK(S) failure (40)
1701
Hard disk(s) Diagnosis failure
1762
Primary master IDE has
changed
Primary slave IDE has
changed
Secondary master IDE has
changed
Secondary slave IDE has
changed
2-10
Action/FRU
Insert the memory modules in the DIMM
sockets properly, then reboot the system.
Memory module. See the "Step 005" of
"Memory" on page 2-31 to replace memory
module.
System board.
Make sure the keyboard is connected
properly and are set correctly in BIOS Setup.
System board.
Unable to reset floppy subsystem.
Floppy Type mismatch.
Make sure the hard disks are set correctly in
BIOS setup.
Hard disk drive cable/connection.
Hard disk drive.
System board.
Make sure that the System Boot Drive
parameter in the Startup Options of BIOS
Setup is not set to [Drive A only].
Load default settings in Setup.
Insert a system diskette into diskette drive
and reboot system.
Make sure the diskette drive configuration
setting in BIOS Setup is correct.
Hard disk drive power.
Diskette drive.
System board.

Advertisement

Table of Contents
loading

Table of Contents